Tailor-made dicationic ionic liquid as a fluorescent sensor for detection of hydroquinone and catechol

被引:66
|
作者
Patil, Sandip K. [1 ]
Patil, Suryakant A. [1 ]
Vadiyar, Madagonda M. [1 ]
Awale, Deepak V. [1 ]
Sartape, Ashish S. [1 ]
Walekar, Laxman S. [2 ]
Kolekar, Govind B. [2 ]
Ghorpade, Uma V. [1 ,3 ,4 ]
Kim, Jin H. [3 ,4 ]
Kolekar, Sanjay S. [1 ]
机构
[1] Shivaji Univ, Dept Chem, Analyt Chem & Mat Sci Res Lab, Kolhapur 416004, Maharashtra, India
[2] Shivaji Univ, Dept Chem, Fluorescence Spect Res Lab, Kolhapur 416004, Maharashtra, India
[3] Chonnam Natl Univ, Dept Mat Sci & Engn, 300 Yongbong Dong, Gwangju 500757, South Korea
[4] Chonnam Natl Univ, Optoelect Convergence Res Ctr, 300 Yongbong Dong, Gwangju 500757, South Korea
关键词
Dicationic ionic liquid; Dihydroxybenzenes; Fluorescence; Hydroquinone; Catechol; ENZYME HYBRID SYSTEM; SELECTIVE DETECTION; COMPOSITE FILM; PICRIC ACID; GRAPHENE; IMIDAZOLIUM; RESORCINOL; ELECTRODE; PHENOL; PROBE;
D O I
10.1016/j.molliq.2017.08.119
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We are exploring a geminal dicationic ionic liquid (DCIL), 1,1'-(propane-1,3-diyl)bis(4-aminopyridin-1-ium) dihydroxide, [C-3(Amp)(2)][OH](2) as a fluorescent probe for detection of dihydroxybenzenes viz. hydroquinone (HQ) and catechol (CC). Simple and sensitive spectrofluorometric method is described which accomplished with efficient quenching of fluorescence of aqueous DCIL by dihydroxybenzenes. The sensor offers good linear detection range of 1-400 mu M and 1-1000 mu M with detection limits of 0.31 mu M and 0.40 mu M for HQ and CC, respectively. Under alkaline conditions HQ/CC oxidizes to corresponding benzoquinones which interact with DCIL and consequently quenching of fluorescence is occurred. This essential alkaline condition is in situ provided by purposefully tuned DCIL to having basic nature. The plausible quenching mechanism that involves photo-induced charge transfer pathway is evidently discussed. The proposed method is competent over a broad detection range. Selectivity of method is demonstrated by scrutinizing intervention of various interfering species. Recoveries from water sample analysis emphasize the possible use of DCIL probe in the detection of HQ and CC from water sources. The proposed method certainly confers a new approach in sensing techniques for dihydroxybenzenes. (C) 2017 Published by Elsevier B.V.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 50 条
  • [21] Tailor-Made Zeolitic Water Nanochannels for Liquid Fuel Production
    Chen, Xiaofang
    Wang, Huanting
    JOULE, 2020, 4 (04) : 710 - 711
  • [22] Synthesis of oligo(diazaphenyls). Tailor-made fluorescent heteroaromatics and pathways to nanostructures
    Gompper, R
    Mair, HJ
    Polborn, K
    SYNTHESIS-STUTTGART, 1997, (06): : 696 - &
  • [23] An efficient and chemoselective deprotection of tert-butyldimethylsilyl (TBDMS) ethers using tailor-made ionic liquid
    Jadhav, Vinod H.
    Lee, Sang Bong
    Jeong, Hwan-Jeong
    Lim, Seok Tae
    Sohn, Myung-Hee
    Kim, Dong Wook
    TETRAHEDRON LETTERS, 2012, 53 (16) : 2051 - 2053
  • [24] A sensor based on the carbon nanotubes-ionic liquid composite for simultaneous determination of hydroquinone and catechol
    Bu, Caihong
    Liu, Xiuhui
    Zhang, Yijun
    Li, Li
    Zhou, Xibin
    Lu, Xiaoquan
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 88 (01) : 292 - 296
  • [25] RECENT DEVELOPMENTS IN TAILOR-MADE LIQUID-CRYSTALLINE POLYMERS
    PERCEC, V
    TOMAZOS, D
    INDIAN JOURNAL OF TECHNOLOGY, 1993, 31 (4-6): : 339 - 392
  • [26] Long-alkyl-chain-derivatized imidazolium salts and ionic liquid crystals with tailor-made properties
    Wang, Xinjiao
    Sternberg, Michelle
    Kohler, Florian T. U.
    Melcher, Berthold U.
    Wasserscheid, Peter
    Meyer, Karsten
    RSC ADVANCES, 2014, 4 (24) : 12476 - 12481
  • [27] Antibodies as tailor-made chiral selectors for detection and separation of stereoisomers
    Hofstetter, H
    Hofstetter, O
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (10) : 869 - 879
  • [28] Enhancing the Selectivity of Enzyme Detection by Using Tailor-Made Nanoparticles
    Liu, Yibin
    Wang, Shanshan
    Zhang, Chen
    Su, Xin
    Huang, Shan
    Zhao, Meiping
    ANALYTICAL CHEMISTRY, 2013, 85 (10) : 4853 - 4857
  • [29] Tailor-made thermoreversible functional polymer via RAFT polymerization in an ionic liquid: a remarkably fast polymerization process
    Singha, Nikhil K.
    Pramanik, Nabendu B.
    Behera, Prasanta K.
    Chakrabarty, Arindam
    Mays, Jimmy W.
    GREEN CHEMISTRY, 2016, 18 (22) : 6115 - 6122
  • [30] Synthesis, optimization and application of tailor-made ionic liquids for heterogeneous polymerization processes
    Guerrero-Sanchez, Carlos
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231