VLBI measurement of the secular aberration drift

被引:76
|
作者
Titov, O. [1 ]
Lambert, S. B. [2 ]
Gontier, A-M [2 ]
机构
[1] Geosci Australia, Canberra, ACT 2601, Australia
[2] CNRS, UMR 8630, Dept Syst Reference Temps Espace SYRTE, Observ Paris, F-75014 Paris, France
关键词
astrometry; reference systems; techniques: interferometric; PRECESSION; INTERFEROMETRY; EXPRESSIONS; NUTATION; INSIGHTS;
D O I
10.1051/0004-6361/201015718
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Aims. While analyzing decades of very long baseline interferometry (VLBI) data, we detected the secular aberration drift of the extragalatic radio source proper motions caused by the rotation of the Solar System barycenter around the Galactic center. Our results agree with the predicted estimate to be 4-6 micro arcseconds per year (mu as/yr) towards alpha = 266 degrees and delta = -29 degrees. In addition, we tried to detect the quadrupole systematics of the velocity field. Methods. The analysis method consisted of three steps. First, we analyzed geodetic and astrometric VLBI data to produce radio source coordinate time series. Second, we fitted proper motions of 555 sources with long observational histories over the period 1990-2010 to their respective coordinate time series. Finally, we fitted vector spherical harmonic components of degrees 1 and 2 to the proper motion field. Results. Within the error bars, the magnitude and the direction of the dipole component agree with predictions. The dipole vector has an amplitude of 6.4 +/- 1.5 mu as/yr and is directed towards equatorial coordinates alpha = 263 degrees and delta = -20 degrees. The quadrupole component has not been detected. The primordial gravitational wave density, integrated over a range of frequencies less than 10(-9) Hz, has a limit of 0.0042 h(-2) where h is the normalized Hubble constant is H-0/(100 kms(-1)).
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Instantaneous drift velocities measurement
    Doubrovski, Victor
    Luniakova, Elizaveta
    PERCEPTION, 2021, 50 (1_SUPPL) : 209 - 209
  • [42] MEASUREMENT OF ELECTRON DRIFT VELOCITIES
    BLEVIN, HA
    HASAN, MZ
    AUSTRALIAN JOURNAL OF PHYSICS, 1967, 20 (06): : 735 - &
  • [43] Odd Aberration in Double-Pass Human Eye's Aberration Measurement System
    Deng Yangchun
    Zhao Junlei
    Dai Yun
    Zhang Yudong
    ACTA OPTICA SINICA, 2018, 38 (08)
  • [44] Aberration measurement and automated alignment of the TEM.
    Chand, G
    Saxton, WO
    Kirkland, AI
    ELECTRON MICROSCOPY AND ANALYSIS 1995, 1995, 147 : 297 - 300
  • [45] MEASUREMENT OF SPHERICAL ABERRATION OF AN ELECTROSTATIC QUADRUPOLE LENS
    FISHKOVA, TY
    BARANOVA, LA
    RADIO ENGINEERING AND ELECTRONIC PHYSICS-USSR, 1968, 13 (08): : 1331 - &
  • [46] Spinning pupil aberration measurement for anisoplanatic deconvolution
    Ancora, Daniele
    Furieri, Tommaso
    Bonora, Stefano
    Bassi, Andrea
    OPTICS LETTERS, 2021, 46 (12) : 2884 - 2887
  • [47] Secular Drift of the Auroral Ovals: How Fast Do They Actually Move?
    Tsyganenko, N. A.
    GEOPHYSICAL RESEARCH LETTERS, 2019, 46 (06) : 3017 - 3023
  • [48] The measurement of the misalignment induced aberration of a miniature lens
    Chang, Hung-Sheng
    Liang, Chao-Wen
    OPTICAL SYSTEM ALIGNMENT, TOLERANCING, AND VERIFICATION XII, 2018, 10747
  • [49] Chromatic aberration measurement for transmission interferometric testing
    Seong, Kibyung
    Greivenkamp, John E.
    APPLIED OPTICS, 2008, 47 (35) : 6508 - 6511
  • [50] Measurement and correction of the eye's chromatic aberration
    Manzanera, S
    Piers, P
    Artal, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46