Determination of nicotine in saliva, urine and wastewater samples using tantalum metal organic framework pipette tip micro-solid phase extraction

被引:0
|
作者
Kahkha, Mohammad Reza Rezaei [1 ,2 ]
Kaykhaii, Massoud [3 ]
Sargazi, Ghasem [4 ]
Kahkha, Batool Rezaei [1 ]
机构
[1] Zabol Univ Med Sci, Fac Hlth, Dept Environm Hlth Engn, Zabol, Iran
[2] Zabol Univ Med Sci, Plant Res Dev Ctr, Zabol, Iran
[3] Univ Sistan & Baluchestan, Fac Sci, Dept Chem, Zahedan, Iran
[4] Res Inst Environm Sci, Environm & Nanochem Dept, High Technol & Environm Sci, Kerman, Iran
关键词
MASS-SPECTROMETRY; COTININE; PRECONCENTRATION; NANOSTRUCTURE;
D O I
10.1039/c9ay01773a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel tantalum metal organic framework (Ta-MOF) was synthesized by a microwave assisted reverse micelle procedure, and it was used as a sorbent for pipette tip micro-solid phase extraction of nicotine from biological and environmental samples. Several parameters that influence the extraction efficiency, such as the amount of sorbent, the volumes of sample solution and eluent solvent, the type of eluent, and the number of draw/eject cycles of sample solution and eluent solvent, were studied and optimized. The results showed that the highest extraction efficiency was obtained when 5 mg Ta-MOF was placed into a 20 mu L pipette tip and 3500 mu L of 5 mg L-1 nicotine solution aspirated and dispensed over the sorbent after 15 cycles. The adsorbed nicotine was washed from the sorbent using 15 mu L of methanol/ammonia solution as an eluent solvent with 20 draw/eject cycles. The linear dynamic range of this method was between 2 and 3000 mu g L-1 and the limit of detection and the limit of quantification were 0.7 and 4.8 mu g L-1, respectively. Intraday and interday precision expressed as relative standard deviation were good and found to be 2.7% and 5.2%, respectively. Finally, the method was successfully applied for the analysis of nicotine in six real samples of human saliva, urine and wastewater.
引用
收藏
页码:6168 / 6175
页数:8
相关论文
共 50 条
  • [41] An automated magnetic dispersive micro-solid phase extraction in a fluidized reactor for the determination of fluoroquinolones in baby food samples
    Vakh, Christina
    Alaboud, Marcel
    Lebedinets, Sofya
    Korolev, Dmitry
    Postnov, Viktor
    Moskvin, Leonid
    Osmolovskaya, Olga
    Bulatov, Andrey
    ANALYTICA CHIMICA ACTA, 2018, 1001 : 59 - 69
  • [42] A Simple Dispersive Micro-Solid Phase Extraction for Determination of Neonicotinoid Insecticides in Surface Water and Fruit Juice Samples
    Vichapong, Jitlada
    Santaladchaiyakit, Yanawath
    Burakham, Rodjana
    Srijaranai, Supalax
    CHIANG MAI JOURNAL OF SCIENCE, 2022, 49 (02): : 387 - 397
  • [43] Self-assembly pipette tip-based cigarette filters for micro-solid phase extraction of ketoconazole cis-enantiomers in urine samples followed by high-performance liquid chromatography/diode array detection
    Andrade, Roseane Teixeira
    Santos da Silva, Ricky Cassio
    Pereira, Arnaldo Cesar
    Borges, Keyller Bastos
    ANALYTICAL METHODS, 2015, 7 (17) : 7270 - 7279
  • [44] Determination of diuretics in human urine using HPLC coupled with magnetic solid-phase extraction based on a metal-organic framework
    Liu, Meng
    Lv, Bingqiang
    Jiang, Hailong
    Yuan, Pei
    Zhu, Huan
    Gao, Binghong
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)
  • [45] Fabrication of a Molecularly Imprinted Polymer Adsorbent for Pipette Tip Micro Solid-phase Extraction of Levofloxacin from Aqueous Samples Prior to its Spectrophotometric Determination
    Hashemi, Sayyed Hossein
    Kaykhaii, Massoud
    Keikha, Ahmad Jamali
    Jangizahi, Jasem
    CURRENT ANALYTICAL CHEMISTRY, 2023, 19 (10) : 721 - 731
  • [46] Dispersive Micro-Solid Phase Extraction Using a Graphene Oxide Nanosheet with Neocuproine and Batocuproine for the Preconcentration of Traces of Metal Ions in Food Samples
    Feist, Barbara
    MOLECULES, 2023, 28 (10):
  • [47] A Rapid LC-HRMS Method for the Determination of Domoic Acid in Urine Using a Self-Assembly Pipette Tip Solid-Phase Extraction
    Zhang, Yiping
    Chen, Dawei
    Hong, Zhuan
    TOXINS, 2016, 8 (01):
  • [48] A high-throughput nanofibers mat-based micro-solid phase extraction for the determination of cationic dyes in wastewater
    Qi, Feifei
    Qian, Liangliang
    Liu, Jingjing
    Li, Xiaoqing
    Lu, Lingeng
    Xu, Qian
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1460 : 24 - 32
  • [49] Triazine-based porous organic polymer as pipette tip solid-phase extraction adsorbent coupled with HPLC for the determination of sulfonamide residues in food samples
    Ning, Yuhan
    Ye, Yixing
    Liao, Wanliang
    Xu, Yang
    Wang, Weiping
    Wang, Ai-jun
    FOOD CHEMISTRY, 2022, 397
  • [50] Magnetic-Nanoparticle-Based Dispersive Micro-Solid Phase Extraction for the Determination of Crystal Violet in Environmental Water Samples
    Shojaei, Siroos
    Rahmani, Mashaallah
    Khajeh, Mostafa
    Abbasian, Ahmad Reza
    CHEMISTRYSELECT, 2021, 6 (19): : 4782 - 4790