Utility of single-shot compressed sensing cardiac magnetic resonance cine imaging for assessment of biventricular function in free-breathing and arrhythmic pediatric patients

被引:8
|
作者
Zou, Qing [1 ,2 ]
Xu, Hua-yan [1 ]
Fu, Chuan [1 ]
Zhou, Xiao-yue [3 ]
Xu, Rong [1 ]
Yang, Meng-xi [4 ]
Yang, Zhi-gang [5 ]
Guo, Ying-kun [1 ]
机构
[1] Sichuan Univ, West China Univ Hosp 2, Dept Radiol, 20 Sect 3 South Renmin Rd, Chengdu 610041, Sichuan, Peoples R China
[2] Deyang Peoples Hosp, Dept Radiol, 173 Sect 3 Tai Shan Rd, Deyang 618400, Sichuan, Peoples R China
[3] Siemens Healthineers Ltd, MR Collaborat, Shanghai, Peoples R China
[4] Sichuan Univ, West China Univ Hosp 2, Minist Educ, Key Lab Birth Defects & Related Dis Women & Child, Chengdu 610041, Peoples R China
[5] Sichuan Univ, West China Hosp, Dept Radiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
关键词
Compressed sensing; Free-breathing; Arrhythmia; Pediatric; Cardiac magnetic resonance; HEART-DISEASE; RESOLUTION; VOLUMES; MRI;
D O I
10.1016/j.ijcard.2021.06.043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aimed to explore the feasibility and accuracy of single-shot compressed-sensing (CS) cardiac magnetic resonance cine technology for the assessment of biventricular function and morphology in free-breathing (FB) pediatrics, especially those with arrhythmia. Methods: Seventy consecutive pediatric participants (6.27 +/- 3.8 years, range:0.5-14 years) were enrolled be-tween August 2019 and July 2020. Single-shot CS and conventional balanced steady-state free-precession (bSSFP) cine were obtained. The total scanning time, image quality and biventricular function parameters were compared for both sequences. Results: Single-shot CS cine had shorter acquisition time compared with the conventional bSSFP cine (all P < 0.001). The single-shot CS cine also had fewer artifacts than conventional bSSFP cine (breath-hold (BH): 4.6 +/- 0.6 vs. 4.3 +/- 0.6; FB without ongoing arrhythmia: 4.5 +/- 0.6 vs. 3.6 +/- 0.9; FB with ongoing arrhythmia: 4.7 +/- 0.5 vs. 2.6 +/- 1.1; all P < 0.05). No statistical difference of left ventricular parameters and right ventricular end-systolic volume/ejection fraction were found between the single-shot CS and conventional bSSFP cine in both BH and FB without ongoing arrhythmia group. There was an excellent correlation (R-2 = 0.60-0.98, all P < 0.001) and good intra-(range: R-2 = 0.57-0.99, P < 0.001)/inter-observer agreements (range: R-2 = 0.76-1, P < 0.001) for single-shot CS cine images in terms of biventricular function parameters. Conclusions: The single-shot CS cine can significantly reduce the image acquisition time, offering reliable quantification of biventricular function in free breathing condition for arrhythmic patients. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 45 条
  • [1] Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T
    Masahiro Takakado
    Tomoyuki Kido
    Ryo Ogawa
    Yoshihiro Takimoto
    Tsuyoshi Tokuda
    Yuki Tanabe
    Naoto Kawaguchi
    Jianing Pang
    Yoshiaki Komori
    Teruhito Kido
    Japanese Journal of Radiology, 2023, 41 : 142 - 152
  • [2] Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T
    Takakado, Masahiro
    Kido, Tomoyuki
    Ogawa, Ryo
    Takimoto, Yoshihiro
    Tokuda, Tsuyoshi
    Tanabe, Yuki
    Kawaguchi, Naoto
    Pang, Jianing
    Komori, Yoshiaki
    Kido, Teruhito
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (02) : 142 - 152
  • [3] Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging
    Kido, Tomoyuki
    Kido, Teruhito
    Nakamura, Masashi
    Watanabe, Kouki
    Schmidt, Michaela
    Forman, Christoph
    Mochizuki, Teruhito
    CIRCULATION JOURNAL, 2017, 81 (10) : 1463 - 1468
  • [4] Feasibility of single-shot compressed sensing cine imaging for analysis of left ventricular function and strain in cardiac MRI
    Chen, Y.
    Qian, W.
    Liu, W.
    Zhu, Y.
    Zhou, X.
    Xu, Y.
    Zhu, X.
    CLINICAL RADIOLOGY, 2021, 76 (06) : 471.e1 - 471.e7
  • [5] Application of single shot free-breathing fast imaging employing steady state sequence in cardiac magnetic resonance imaging
    Wang, Lidong
    Cheng, Liuquan
    Fang, Fang
    Han, Xiaodong
    Liu, Aishi
    Ma, Lin
    Gao, Peiyi
    Niu, Guangming
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2015, 35 (02) : 159 - 166
  • [6] Free-Breathing Single Navigator Gated Cine Cardiac Magnetic Resonance at 3 T: Feasibility Study in Patients
    Abd-Elmoniem, Khaled Z.
    Obele, Chika C.
    Sibley, Christopher T.
    Matta, Jatin R.
    Pettigrew, Roderic I.
    Gharib, Ahmed M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (03) : 382 - 386
  • [7] Free-Breathing Compressed Sensing Cine Cardiac MRI for Assessment of Left Ventricular Strain by Feature Tracking in Children
    Xu, Ke
    Xu, Rong
    Xu, Hua-yan
    Xie, Lin-jun
    Yang, Zhi-gang
    Fu, Hang
    Bai, Wei
    Zhang, Lu
    Zhou, Xiao-yue
    Guo, Ying-kun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (05) : 1832 - 1840
  • [8] Cardiac cine with compressed sensing real-time imaging and retrospective motion correction for free-breathing assessment of left ventricular function and strain in clinical practice
    Li, Yanyu
    Lin, Lu
    Wang, Jian
    Cao, Likun
    Liu, Yajing
    Pang, Jianing
    An, Jing
    Jin, Zhengyu
    Wang, Yining
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2262 - +
  • [9] Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation
    Lu Lin
    Yanyu Li
    Jian Wang
    Likun Cao
    Yajing Liu
    Jianing Pang
    Jing An
    Zhengyu Jin
    Yining Wang
    European Radiology, 2023, 33 : 2289 - 2300
  • [10] Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation
    Lin, Lu
    Li, Yanyu
    Wang, Jian
    Cao, Likun
    Liu, Yajing
    Pang, Jianing
    An, Jing
    Jin, Zhengyu
    Wang, Yining
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2289 - 2300