Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T

被引:0
|
作者
Takakado, Masahiro [1 ]
Kido, Tomoyuki [1 ]
Ogawa, Ryo [1 ]
Takimoto, Yoshihiro [2 ]
Tokuda, Tsuyoshi [1 ]
Tanabe, Yuki [1 ]
Kawaguchi, Naoto [1 ]
Pang, Jianing [3 ]
Komori, Yoshiaki [4 ]
Kido, Teruhito [1 ]
机构
[1] Ehime Univ, Dept Radiol, Grad Sch Med, Toon, Ehime, Japan
[2] Ehime Univ Hosp, Toon, Ehime, Japan
[3] Siemens Med Solut USA Inc, Chicago, IL USA
[4] Siemens Healthcare KK, Tokyo, Japan
关键词
Cardiovascular magnetic resonance; Compressed sensing; Free breathing; Motion correction; Cine; MRI;
D O I
10.1007/s11604-022-01344-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We applied a combination of compressed-sensing (CS) and retrospective motion correction to free-breathing cine magnetic resonance (MR) (FBCS cine MoCo). We validated FBCS cine MoCo by comparing it with breath-hold (BH) conventional cine MR. Materials and methods Thirty-five volunteers underwent both FBCS cine MoCo and BH conventional cine MR imaging. Twelve consecutive short-axis cine images were obtained. We compared the examination time, image quality and biventricular volumetric assessments between the two cine MR. Results FBCS cine MoCo required a significantly shorter examination time than BH conventional cine (135 s [110-143 s] vs. 198 s [186-349 s], p < 0.001). The image quality scores were not significantly different between the two techniques (End-diastole: FBCS cine MoCo; 4.7 +/- 0.5 vs. BH conventional cine; 4.6 +/- 0.6; p = 0.77, End-systole: FBCS cine MoCo; 4.5 +/- 0.5 vs. BH conventional cine; 4.5 +/- 0.6; p = 0.52). No significant differences were observed in all biventricular volumetric assessments between the two techniques. The mean differences with 95% confidence interval (CI), based on Bland-Altman analysis, were - 0.3 mL (- 8.2 - 7.5 mL) for LVEDV, 0.2 mL (- 5.6 - 5.9 mL) for LVESV, - 0.5 mL (- 6.3 - 5.2 mL) for LVSV, - 0.3% (- 3.5 - 3.0%) for LVEF, - 0.1 g (- 8.5 - 8.3 g) for LVED mass, 1.4 mL (- 15.5 - 18.3 mL) for RVEDV, 2.1 mL (- 11.2 - 15.3 mL) for RVESV, - 0.6 mL (- 9.7 - 8.4 mL) for RVSV, - 1.0% (- 6.5 - 4.6%) for RVEF. Conclusion FBCS cine MoCo can potentially replace multiple BH conventional cine MR and improve the clinical utility of cine MR.
引用
收藏
页码:142 / 152
页数:11
相关论文
共 50 条
  • [1] Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T
    Masahiro Takakado
    Tomoyuki Kido
    Ryo Ogawa
    Yoshihiro Takimoto
    Tsuyoshi Tokuda
    Yuki Tanabe
    Naoto Kawaguchi
    Jianing Pang
    Yoshiaki Komori
    Teruhito Kido
    Japanese Journal of Radiology, 2023, 41 : 142 - 152
  • [2] Utility of single-shot compressed sensing cardiac magnetic resonance cine imaging for assessment of biventricular function in free-breathing and arrhythmic pediatric patients
    Zou, Qing
    Xu, Hua-yan
    Fu, Chuan
    Zhou, Xiao-yue
    Xu, Rong
    Yang, Meng-xi
    Yang, Zhi-gang
    Guo, Ying-kun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 338 : 258 - 264
  • [3] Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation
    Lu Lin
    Yanyu Li
    Jian Wang
    Likun Cao
    Yajing Liu
    Jianing Pang
    Jing An
    Zhengyu Jin
    Yining Wang
    European Radiology, 2023, 33 : 2289 - 2300
  • [4] Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation
    Lin, Lu
    Li, Yanyu
    Wang, Jian
    Cao, Likun
    Liu, Yajing
    Pang, Jianing
    An, Jing
    Jin, Zhengyu
    Wang, Yining
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2289 - 2300
  • [5] Cardiac cine with compressed sensing real-time imaging and retrospective motion correction for free-breathing assessment of left ventricular function and strain in clinical practice
    Li, Yanyu
    Lin, Lu
    Wang, Jian
    Cao, Likun
    Liu, Yajing
    Pang, Jianing
    An, Jing
    Jin, Zhengyu
    Wang, Yining
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2262 - +
  • [6] Accelerated free-breathing 3D T1 cardiovascular magnetic resonance using multicoil compressed sensing
    Iyer, Srikant Kamesh
    Moon, Brianna
    Hwuang, Eileen
    Han, Yuchi
    Solomon, Michael
    Litt, Harold
    Witschey, Walter R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
  • [7] Accelerated free-breathing 3D T1ρ cardiovascular magnetic resonance using multicoil compressed sensing
    Srikant Kamesh Iyer
    Brianna Moon
    Eileen Hwuang
    Yuchi Han
    Michael Solomon
    Harold Litt
    Walter R. Witschey
    Journal of Cardiovascular Magnetic Resonance, 21
  • [8] Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)
    Zhou, Ruixi
    Yang, Yang
    Mathew, Roshin C.
    Mugler, John P., III
    Weller, Daniel S.
    Kramer, Christopher M.
    Ahmed, Abdul Haseeb
    Jacob, Mathews
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 706 - 720
  • [9] Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging
    Kido, Tomoyuki
    Kido, Teruhito
    Nakamura, Masashi
    Watanabe, Kouki
    Schmidt, Michaela
    Forman, Christoph
    Mochizuki, Teruhito
    CIRCULATION JOURNAL, 2017, 81 (10) : 1463 - 1468
  • [10] Correction to: Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
    Ruixi Zhou
    Wei Huang
    Yang Yang
    Xiao Chen
    Daniel S. Weller
    Christopher M. Kramer
    Sebastian Kozerke
    Michael Salerno
    Journal of Cardiovascular Magnetic Resonance, 20