Intracardiac Electrogram T-Wave Alternans/Variability Increases Before Spontaneous Ventricular Tachyarrhythmias in Implantable Cardioverter-Defibrillator Patients A Prospective, Multi-Center Study

被引:42
|
作者
Swerdlow, Charles [1 ]
Chow, Theodore [2 ]
Das, Mithilesh [3 ]
Gillis, Anne M. [4 ]
Zhou, Xiaohong [5 ]
Abeyratne, Athula [5 ]
Ghanem, Raja N. [5 ]
机构
[1] Cedars Sinai Heart Inst, Los Angeles, CA USA
[2] Ohio Heart & Vasc Ctr, Cincinnati, OH USA
[3] Indiana Univ Sch Med, Indianapolis, IN USA
[4] Univ Calgary, Fac Med, Calgary, AB, Canada
[5] Medtronic Inc, Mounds View, MN USA
关键词
implantable cardioverter defibrillator; tachyarrhythmias; T-wave alternans; CARDIAC ELECTRICAL INSTABILITY; REPOLARIZATION ALTERNANS; FIBRILLATION; ARRHYTHMIAS; OSCILLATIONS; TACHYCARDIA; PREDICTOR; DEATH; MODEL;
D O I
10.1161/CIRCULATIONAHA.110.986364
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-T-wave alternans (TWA) increases before ventricular tachycardia (VT) or fibrillation (VF), suggesting that it may warn of VT/VF in implantable cardioverter-defibrillator patients. Recently, we described a method for measuring alternans and nonalternans variability (TWA/V) from electrograms (EGMs) stored in implantable cardioverter-defibrillators before VT/VF. The goal of this prospective, multicenter study was to determine whether EGM TWA/V was greater before VT/VF than at baseline. Methods and Results-We enrolled 63 implantable cardioverter-defibrillator patients. TWA/V was computed from stored EGMs before spontaneous VT/VF and from sequential windows of 8 pairs of beats using 4 different control recordings: baseline rhythm, rapid pacing at 105 bpm, segments of ambulatory Holter EGMs matched to the time of VT/VF episodes, and EGMs before spontaneous supraventricular tachycardia. During follow-up, 28 patients had 166 episodes of VT/VF. TWA/V was greater before VT/VF (62.9 +/- 3.1 mu V; n=28) than during baseline rhythm (12.8 +/- 1.8 mu V; P < 0.0001; n=62), during rapid pacing (14.5 +/- 2.0 mu V; P < 0.0001; n=52), before supraventricular tachycardia (27.5 +/- 6.1 mu V; P < 0.0001; n=9), or during time-matched ambulatory controls (12.3 +/- 3.5 mu V; P < 0.0001; n=16). By logistic regression, the odds of VT/VF increased by a factor of 2.2 for each 10-mu V increment in TWA/V (P < 0.0001). Conclusions-In implantable cardioverter-defibrillator patients, EGM TWA/V is greater before spontaneous VT/VF than in control recordings. Future implantable cardioverter-defibrillators that measure EGM TWA/V continuously may warn patients and initiate pacing therapies to prevent VT/VF. (Circulation. 2011; 123: 1052-1060.)
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [21] Prospective Use of Microvolt T-Wave Alternans Testing to Guide Primary Prevention Implantable Cardioverter Defibrillator Therapy
    Merchant, Faisal M.
    Salerno-Uriarte, Jorge A.
    Caravati, Fabrizio
    Falcone, Stefania
    Molon, Giulio
    Marangoni, Daniele
    Raczak, Grzegorz
    Danilowicz-Szymanowicz, Ludmila
    Pedretti, Roberto F. E.
    Braga, Simona Sarzi
    Ikeda, Takanori
    Calo, Leonardo
    Martino, Annamaria
    Erciyes, Demet
    Piancastelli, Maurizio
    Maury, Philippe
    Cohen, Richard J.
    Armoundas, Antonis A.
    CIRCULATION JOURNAL, 2015, 79 (09) : 1912 - 1919
  • [22] Comparability of Noninvasive Microvolt T-Wave Alternans Versus Invasive Ventricular Programmed Stimulation to Guide Implantable Cardioverter-Defibrillator Implantation in Patients at Risk of Sudden Death
    Feld, Gregory K.
    Clopton, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (06) : 480 - 482
  • [23] Application of microvolt T-wave alternans testing in scheduling implantable cardioverter-defibrillator placement for the primary prevention of sudden cardiac death in patients with left ventricular dysfunction
    Danilowicz-Szymanowicz, Ludmila
    Suchecka, Justyna
    Zagozdzon, Pawel
    Szwoch, Malgorzata
    Kempa, Maciej
    Raczak, Grzegorz
    KARDIOLOGIA POLSKA, 2015, 73 (06) : 429 - 436
  • [24] The problem of indeterminate microvolt T-wave alternans results in patients with left ventricular dysfunction referred for implantable cardioverter-defibrillator implantation in the primary prevention of sudden cardiac death
    Danilowicz-Szymanowicz, Ludmila
    Szwoch, Malgorzata
    Kempa, Maciej
    Raczak, Grzegorz
    KARDIOLOGIA POLSKA, 2012, 70 (08) : 795 - 802
  • [25] Should microvolt T-wave alternans be utilized routinely in selecting patients for prophylactic implantable cardioverter-defibrillator insertion in the setting of ischemic heart disease?
    Russo, Andrea M.
    Marchlinski, Francis E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (01) : 59 - 61
  • [26] Intracardiac J-point elevation before the onset of polymorphic ventricular tachycardia and ventricular fibrillation in patients with an implantable cardioverter-defibrillator
    Tereshchenko, Larisa G.
    McCabe, Aaron
    Han, Lichy
    Sur, Sanjoli
    Huang, Timothy
    Marine, Joseph E.
    Cheng, Alan
    Spragg, David D.
    Sinha, Sunil
    Calkins, Hugh
    Stein, Kenneth
    Tomaselli, Gordon F.
    Berger, Ronald D.
    HEART RHYTHM, 2012, 9 (10) : 1594 - 1602
  • [27] Microvolt T-wave alternans as a predictor of ventricular tachyarrhythmias - A prospective study using atrial pacing
    Tanno, KR
    Ryu, S
    Watanabe, N
    Minoura, Y
    Kawamura, M
    Asano, T
    Kobayashi, Y
    Katagiri, T
    CIRCULATION, 2004, 109 (15) : 1854 - 1858
  • [28] Microvolt T-wave alternans as a predictor of ventricular tachyarrhythmias: A prospective study using atrial pacing
    Tanno, K
    Watanabe, N
    Ryu, S
    Minoura, Y
    Kawamura, M
    Asano, T
    Kobayashi, Y
    Katagiri, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 141A - 141A
  • [29] Microvolt T-wave alternans and other noninvasive predictors of serious arrhythmic events in patients with an implanted cardioverter-defibrillator
    Sredniawa, Beata
    Kowalczyk, Jacek
    Lenarczyk, Radoslaw
    Kowalski, Oskar
    Sedkowska, Agnieszka
    Cebula, Sylwia
    Musialik-Lydka, Agata
    Kalarus, Zbigniew
    KARDIOLOGIA POLSKA, 2012, 70 (05) : 447 - 455
  • [30] A fully automatic, implantable cardioverter-defibrillator algorithm to prevent inappropriate detection of ventricular tachycardia or fibrillation due to T-wave oversensing in spontaneous rhythm
    Cao, Jian
    Gillberg, Jeffrey M.
    Swerdlow, Charles D.
    HEART RHYTHM, 2012, 9 (04) : 522 - 530