Intracardiac Electrogram T-Wave Alternans/Variability Increases Before Spontaneous Ventricular Tachyarrhythmias in Implantable Cardioverter-Defibrillator Patients A Prospective, Multi-Center Study

被引:42
|
作者
Swerdlow, Charles [1 ]
Chow, Theodore [2 ]
Das, Mithilesh [3 ]
Gillis, Anne M. [4 ]
Zhou, Xiaohong [5 ]
Abeyratne, Athula [5 ]
Ghanem, Raja N. [5 ]
机构
[1] Cedars Sinai Heart Inst, Los Angeles, CA USA
[2] Ohio Heart & Vasc Ctr, Cincinnati, OH USA
[3] Indiana Univ Sch Med, Indianapolis, IN USA
[4] Univ Calgary, Fac Med, Calgary, AB, Canada
[5] Medtronic Inc, Mounds View, MN USA
关键词
implantable cardioverter defibrillator; tachyarrhythmias; T-wave alternans; CARDIAC ELECTRICAL INSTABILITY; REPOLARIZATION ALTERNANS; FIBRILLATION; ARRHYTHMIAS; OSCILLATIONS; TACHYCARDIA; PREDICTOR; DEATH; MODEL;
D O I
10.1161/CIRCULATIONAHA.110.986364
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-T-wave alternans (TWA) increases before ventricular tachycardia (VT) or fibrillation (VF), suggesting that it may warn of VT/VF in implantable cardioverter-defibrillator patients. Recently, we described a method for measuring alternans and nonalternans variability (TWA/V) from electrograms (EGMs) stored in implantable cardioverter-defibrillators before VT/VF. The goal of this prospective, multicenter study was to determine whether EGM TWA/V was greater before VT/VF than at baseline. Methods and Results-We enrolled 63 implantable cardioverter-defibrillator patients. TWA/V was computed from stored EGMs before spontaneous VT/VF and from sequential windows of 8 pairs of beats using 4 different control recordings: baseline rhythm, rapid pacing at 105 bpm, segments of ambulatory Holter EGMs matched to the time of VT/VF episodes, and EGMs before spontaneous supraventricular tachycardia. During follow-up, 28 patients had 166 episodes of VT/VF. TWA/V was greater before VT/VF (62.9 +/- 3.1 mu V; n=28) than during baseline rhythm (12.8 +/- 1.8 mu V; P < 0.0001; n=62), during rapid pacing (14.5 +/- 2.0 mu V; P < 0.0001; n=52), before supraventricular tachycardia (27.5 +/- 6.1 mu V; P < 0.0001; n=9), or during time-matched ambulatory controls (12.3 +/- 3.5 mu V; P < 0.0001; n=16). By logistic regression, the odds of VT/VF increased by a factor of 2.2 for each 10-mu V increment in TWA/V (P < 0.0001). Conclusions-In implantable cardioverter-defibrillator patients, EGM TWA/V is greater before spontaneous VT/VF than in control recordings. Future implantable cardioverter-defibrillators that measure EGM TWA/V continuously may warn patients and initiate pacing therapies to prevent VT/VF. (Circulation. 2011; 123: 1052-1060.)
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [1] Various patterns of intracardiac electrogram T-wave alternans prior to ventricular tachyarrhythmias in implantable cardioverter-defibrillator patients
    Ikeda, Takanori
    Yusu, Satoru
    Yokoyama, Yasuhiro
    HEART RHYTHM, 2012, 9 (07) : 1033 - 1037
  • [2] Implantable cardioverter-defibrillator shocks increase T-wave alternans
    Lampert, Rachel
    Shusterman, Vladimir
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (09) : E25 - E25
  • [3] Implantable cardioverter-defibrillator shocks increase T-wave alternans
    Lampert, Rachel
    Soufer, Robert
    McPherson, Craig A.
    Batsford, William P.
    Tirado, Stephanie
    Earley, Christine
    Goldberg, Anna
    Shusterman, Vladimir
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (05) : 512 - 517
  • [4] Implantable cardioverter-defibrillator shocks increase T-Wave Alternans
    Lampert, Rachel J.
    Soufer, Robert
    McPherson, Craig A.
    Batsford, William P.
    Tirado, Stephanie
    Earley, Christine
    Goldberg, Anna
    Shusterman, Vladimir
    CIRCULATION, 2006, 114 (18) : 475 - 475
  • [5] Detection of T-wave alternans using an implantable cardioverter-defibrillator
    Paz, Offir
    Zhou, Xiaohong
    Gillberg, Jeff
    Tseng, Hsiang-Jer
    Gang, Eli
    Swerdlow, Charles
    HEART RHYTHM, 2006, 3 (07) : 791 - 797
  • [6] Circadian pattern of spontaneous ventricular tachyarrhythmias in patients with implantable cardioverter-defibrillator
    Fries, R
    Heisel, A
    Jung, J
    Stopp, M
    Schieffer, H
    Ozbek, C
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 (02): : 140 - 147
  • [7] MICROVOLT T-WAVE ALTERNANS AS A PREDICTOR OF MORTALITY AND SEVERE ARRHYTHMIAS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    Zhang, Cun-Tai
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E735 - E735
  • [8] Defibillator Electrogram T Wave Alternans as a Predictor of Spontaneous Ventricular Tachyarrhythmias in Defibrillator Recipients
    Kim, Jin Won
    Pak, Hui-Nam
    Park, Jae Hyung
    Nam, Gi-Byoung
    Kim, Sook Kyoung
    Lee, Hyun Soo
    Jang, Jin Kun
    Choi, Jong Il
    Kim, Young-Hoon
    CIRCULATION JOURNAL, 2009, 73 (01) : 55 - 62
  • [9] T-wave alternans, heart rate turbulence and ventricular extrasystoles for the prediction of appropriate implantable cardioverter-defibrillator discharges
    Seegers, J.
    Exposito, P. Munoz
    Hofschulte, F.
    Wessels, A.
    Lercher, H.
    Sohns, C.
    Luethje, L.
    Vollmann, D.
    Hasenfuss, G.
    Zabel, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 266 - 266
  • [10] Feasibility of T-wave alternans testing in patients considered for a cardioverter-defibrillator implantation
    J. E. Madias
    Netherlands Heart Journal, 2012, 20 : 247 - 247