Ultra-Performance Liquid Chromatography High-Resolution Mass Spectrometry and Direct Infusion-High-Resolution Mass Spectrometry for Combined Exploratory and Targeted Metabolic Profiling of Human Urine

被引:17
|
作者
Chekmeneva, Elena [1 ,5 ]
Correia, Goncalo dos Santos [1 ,5 ]
Gomez-Romero, Maria [1 ,5 ]
Stamler, Jeremiah [2 ]
Chan, Queenie [3 ,4 ]
Elliott, Paul [3 ,4 ]
Nicholson, Jeremy K. [1 ,5 ]
Holmes, Elaine [1 ,4 ]
机构
[1] Imperial Coll London, Dept Surg & Canc, Div Integrat Syst & Digest Med, Sir Alexander Fleming Bldg, London SW7 2AZ, England
[2] Northwestern Univ, Dept Prevent Med, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Imperial Coll London, Sch Publ Hlth, Dept Epidemiol & Biostat, St Marys Campus, London W2 1PG, England
[4] Imperial Coll London, Sch Publ Hlth, MRC PHE Ctr Environm & Hlth, St Marys Campus, London W2 1PG, England
[5] Imperial Coll London, Dept Surg & Canc, NIHR BRC Clin Phenotyping Ctr, Sir Alexander Fleming Bldg, London SW7 2AZ, England
基金
英国医学研究理事会; 美国国家卫生研究院;
关键词
ultra performance liquid chromatography; direct infusion mass spectrometry; metabolic profiling; exploratory analysis; quantitative analysis; high-throughput analysis; LARGE-SCALE; NMR-SPECTROSCOPY; BIOLOGICAL SAMPLES; MS; IDENTIFICATION; PLASMA; SERUM; ANNOTATION; PHENOTYPE; DILUTION;
D O I
10.1021/acs.jproteome.8b00413
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of metabolic phenotyping to epidemiological studies involving thousands of biofluid samples presents a challenge for the selection of analytical platforms that meet the requirements of high-throughput precision analysis and cost-effectiveness. Here direct infusion nanoelectrospray (DI-nESI) was compared with an ultra performance liquid chromatography (UPLC)-high-resolution mass spectrometry (HRMS) method for metabolic profiling of an exemplary set of 132 human urine samples from a large epidemiological cohort. Both methods were developed and optimized to allow the simultaneous collection of high-resolution urinary metabolic profiles and quantitative data for a selected panel of 35 metabolites. The total run time for measuring the sample set in both polarities by UPLC-HRMS was 5 days compared with 9 h by DI-nESI-HRMS. To compare the classification ability of the two MS methods, we performed exploratory analysis of the full-scan HRMS profiles to detect sex-related differences in biochemical composition. Although metabolite identification is less specific in DI-nESI-HRMS, the significant features responsible for discrimination between sexes were mostly the same in both MS-based platforms. Using the quantitative data, we showed that 10 metabolites have strong correlation (Pearson's r > 0.9 and Passing-Bablok regression slope of 0.8-1.3) and good agreement assessed by Bland-Altman plots between UPLC-HRMS and DI-nESI-HRMS and thus can be measured using a cheaper and less sample- and time-consuming method. A further twenty metabolites showed acceptable correlation between the two methods with only five metabolites showing weak correlation (Pearson's r < 0.4) and poor agreement due to the overestimation of the results by DI-nESI-HRMS.
引用
收藏
页码:3492 / 3502
页数:11
相关论文
共 50 条
  • [41] Intact protein bioanalysis by liquid chromatography - High-resolution mass spectrometry
    Bults, Peter
    Spanov, Baubek
    Olaleye, Oladapo
    van de Merbel, Nico C.
    Bischoff, Rainer
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1110 : 155 - 167
  • [42] Profiling Polyphenols in Brown Seaweed by Liquid Chromatography - High Resolution Mass Spectrometry
    Steevensz, Aaron
    Hankinson, Rachael
    Craft, Cheryl
    MacKinnon, Shawna
    Melanson, Jeremy
    PHARMACEUTICAL BIOLOGY, 2010, 48 : 9 - 9
  • [43] Comprehensive steroid profiling by liquid chromatography coupled to high it resolution mass spectrometry
    Kaabia, Zied
    Laparre, Jerome
    Cesbron, Nora
    Le Bizec, Bruno
    Dervilly-Pinel, Gaud
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2018, 183 : 106 - 115
  • [44] Triacylglycerol profiling of microalgae strains for biofuel feedstock by liquid chromatography–high-resolution mass spectrometry
    Karen M. MacDougall
    Jesse McNichol
    Patrick J. McGinn
    Stephen J. B. O’Leary
    Jeremy E. Melanson
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2609 - 2616
  • [45] Cannabinoid Profiling of Hemp Seed Oil by Liquid Chromatography Coupled to High-Resolution Mass Spectrometry
    Citti, Cinzia
    Linciano, Pasquale
    Panseri, Sara
    Vezzalini, Francesca
    Forni, Flavio
    Vandelli, Maria Angela
    Cannazza, Giuseppe
    FRONTIERS IN PLANT SCIENCE, 2019, 10
  • [46] Vitamin E analysis by ultra-performance convergence chromatography and structural elucidation of novel α-tocodienol by high-resolution mass spectrometry
    Gee, Ping Tou
    Liew, Chen Yee
    Thong, Meng Chil
    Gay, Melvin C. L.
    FOOD CHEMISTRY, 2016, 196 : 367 - 373
  • [47] HIGH-RESOLUTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    WOLSTENHOLME, WA
    RAPP, U
    KAUFMANN, H
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 174 (SEP): : 52 - 52
  • [48] Method for detection of naturally occurring toxins in human urine using liquid chromatography high-resolution mass spectrometry
    Hettick, Bryan E.
    Saddy, Anisha
    Krajewski, Logan C.
    Johnson, Rudolph C.
    Hamelin, Elizabeth, I
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2024, 49 (01) : 36 - 42
  • [49] Ultra-Trace Analysis of Cyanotoxins by Liquid Chromatography Coupled to High-Resolution Mass Spectrometry
    Filatova, Daria
    Nunez, Oscar
    Farre, Marinella
    TOXINS, 2020, 12 (04)
  • [50] Resolution Ladder for High-Resolution Mass Spectrometry
    Schittmayer, Matthias
    Birner-Gruenberger, Ruth
    ANALYTICAL CHEMISTRY, 2017, 89 (18) : 9611 - 9615