A cell-based high-throughput screening assay for radiation susceptibility using automated cell counting

被引:7
|
作者
Hodzic, Jasmina [1 ]
Dingjan, Ilse [1 ]
Maas, Marielle J. P. [1 ]
van der Meulen-Muileman, Ida H. [1 ]
de Menezes, Renee X. [2 ]
Heukelom, Stan [3 ]
Verheij, Marcel [4 ]
Gerritsen, Winald R. [1 ]
Geldof, Albert A. [3 ,5 ]
van Triest, Baukelien [4 ]
van Beusechem, Victor W. [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Med Oncol, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Epidemiol & Biostat, NL-1081 HV Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Med Ctr, Dept Radiol & Nucl Med, NL-1081 HV Amsterdam, Netherlands
[4] Netherlands Canc Inst, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Med Ctr, Dept Urol, NL-1081 HV Amsterdam, Netherlands
来源
RADIATION ONCOLOGY | 2015年 / 10卷
关键词
Radiosensitization; High-throughput screening; Microplate laser scanning; Assay development; TARGETED RADIOSENSITIZATION; GENOMIC INSTABILITY; PROSTATE-CANCER; RADIOTHERAPY; CHEMOTHERAPY; CONCOMITANT; CHEMORADIOTHERAPY; METAANALYSIS; INHIBITION; MECHANISMS;
D O I
10.1186/s13014-015-0355-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Radiotherapy is one of the mainstays in the treatment for cancer, but its success can be limited due to inherent or acquired resistance. Mechanisms underlying radioresistance in various cancers are poorly understood and available radiosensitizers have shown only modest clinical benefit. There is thus a need to identify new targets and drugs for more effective sensitization of cancer cells to irradiation. Compound and RNA interference high-throughput screening technologies allow comprehensive enterprises to identify new agents and targets for radiosensitization. However, the gold standard assay to investigate radiosensitivity of cancer cells in vitro, the colony formation assay (CFA), is unsuitable for high-throughput screening. Methods: We developed a new high-throughput screening method for determining radiation susceptibility. Fast and uniform irradiation of batches up to 30 microplates was achieved using a Perspex container and a clinically employed linear accelerator. The readout was done by automated counting of fluorescently stained nuclei using the Acumen eX3 laser scanning cytometer. Assay performance was compared to that of the CFA and the CellTiter-Blue homogeneous uniform-well cell viability assay. The assay was validated in a whole-genome siRNA library screening setting using PC-3 prostate cancer cells. Results: On 4 different cancer cell lines, the automated cell counting assay produced radiation dose response curves that followed a linear-quadratic equation and that exhibited a better correlation to the results of the CFA than did the cell viability assay. Moreover, the cell counting assay could be used to detect radiosensitization by silencing DNA-PKcs or by adding caffeine. In a high-throughput screening setting, using 4 Gy irradiated and control PC-3 cells, the effects of DNA-PKcs siRNA and non-targeting control siRNA could be clearly discriminated. Conclusions: We developed a simple assay for radiation susceptibility that can be used for high-throughput screening. This will aid the identification of molecular targets for radiosensitization, thereby contributing to improving the efficacy of radiotherapy.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Development of high-throughput screening system for osteogenic drugs using a cell-based sensor
    Hojo, Hironori
    Igawa, Kazuyo
    Ohba, Shinsuke
    Yano, Fumiko
    Nakajima, Keiji
    Komiyama, Yuske
    Ikeda, Toshiyuki
    Lichtler, Alexander C.
    Woo, Je-Tae
    Yonezawa, Takayuki
    Takato, Tsuyoshi
    Chung, Ung-il
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2008, 376 (02) : 375 - 379
  • [32] High-Throughput Screening: today's biochemical and cell-based approaches
    Blay, Vincent
    Tolani, Bhairavi
    Ho, Sunita P.
    Arkin, Michelle R.
    DRUG DISCOVERY TODAY, 2020, 25 (10) : 1807 - 1821
  • [33] High-throughput stem cell-based phenotypic screening through microniches
    Kolb, Laura
    Allazetta, Simone
    Karlsson, Maria
    Girgin, Mehmet
    Weber, Wilfried
    Lutolf, Matthias P.
    BIOMATERIALS SCIENCE, 2019, 7 (08) : 3471 - 3479
  • [34] A robust high-throughput sandwich cell-based drug screening platform
    Zhang, Shufang
    Tong, Wenhao
    Zheng, Baixue
    Susanto, Thomas A. K.
    Xia, Lei
    Zhang, Chi
    Ananthanarayanan, Abhishek
    Tuo, Xiaoye
    Sakban, Rashidah B.
    Jia, Ruirui
    Iliescu, Ciprian
    Chai, Kah-Hin
    McMillian, Michael
    Shen, Shali
    Leo, Hwaliang
    Yu, Hanry
    BIOMATERIALS, 2011, 32 (04) : 1229 - 1241
  • [35] Development and validation of cell-based TFEB translocation assay in a high-content and high-throughput screening format
    Zhang, Li
    Huang, Ruili
    Ding, Wen Xing
    Xia, Menghang
    CANCER RESEARCH, 2019, 79 (13)
  • [36] Development and validation of a cell-based high-throughput screening assay for TRPM2 channel modulators
    Song, Yumei
    Buelow, Ben
    Perraud, Anne-Laure
    Scharenberg, Andrew M.
    JOURNAL OF BIOMOLECULAR SCREENING, 2008, 13 (01) : 54 - 61
  • [37] Fluorescent cell-based and bead-based assays for high-throughput screening
    Heinrich, M
    AMERICAN LABORATORY, 2000, 32 (14) : 22 - +
  • [38] High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
    Sundberg, SA
    CURRENT OPINION IN BIOTECHNOLOGY, 2000, 11 (01) : 47 - 53
  • [39] A Saccharomyces cerevisiae cell-based quantitative β-galactosidase handling and assay compatible with robotic high-throughput screening
    de Almeida, Rogerio Alves
    Burgess, Danielle
    Shema, Reut
    Motlekar, Nuzhat
    Napper, Andrew D.
    Diamond, Scott L.
    Pavitt, Graham D.
    YEAST, 2008, 25 (01) : 71 - 76
  • [40] High-throughput target discovery using cell-based genetics
    Jackson, RD
    Harrington, JI
    DRUG DISCOVERY TODAY, 2005, 10 (01) : 53 - 60