MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils

被引:0
|
作者
Gonner, F
Heid, O
Remonda, L
Nicoli, G
Baumgartner, RW
Godoy, N
Schroth, G
机构
[1] Univ Bern, Dept Neuroradiol, Bern, Switzerland
[2] Univ Bern, Dept Neurol, Bern, Switzerland
[3] Univ Bern, Dept Neurosurg, Bern, Switzerland
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We evaluated a time-of-flight three-dimensional MR angiographic sequence with an ultrashort echo time for its ability to characterize the perfusional state of cerebral aneurysms that had been treated with Guglielmi detachable coils and to depict adjacent cerebral arteries. The results mere compared with findings tit conventional MR angiography and digital subtraction angiography. Adjacent vessels were seen better in 36% of patients imaged with the new technique, Both MR angiographic methods detected residual cerebral aneurysmal perfusion with a tendency to overestimate the patent portion of the aneurysm.
引用
收藏
页码:1324 / 1328
页数:5
相关论文
共 50 条
  • [41] Endovascular treatment of ophthalmic segment aneurysms with Guglielmi detachable coils
    Roy, D
    Raymond, J
    Bouthillier, A
    Bojanowski, MW
    Moumdjian, R
    LEsperance, G
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (07) : 1207 - 1215
  • [42] Embolization of intracranial aneurysms with Guglielmi detachable coils augmented by microballoons
    Sanders, WP
    Burke, TH
    Mehta, BA
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (05) : 917 - 920
  • [43] Evaluation of the stability of intracranial aneurysms occluded with Guglielmi detachable coils
    Tamatani, S
    Ito, Y
    Koike, T
    Abe, H
    Kumagai, T
    Takeuchi, S
    Tanaka, R
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2001, 7 : 143 - 148
  • [44] ENDOVASCULAR TREATMENT OF BASILAR TIP ANEURYSMS WITH GUGLIELMI DETACHABLE COILS
    AHUJA, A
    GRAVES, VB
    BARNWELL, SL
    HOPKINS, LN
    STROTHERS, CM
    [J]. JOURNAL OF NEUROSURGERY, 1995, 82 (02) : A358 - A358
  • [45] Detection capability of the necessity for reembolization of three types of MR angiography in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils
    Ueda, F
    Matsui, O
    Suzuki, M
    Sanada, J
    Terayama, N
    [J]. RADIOLOGY, 2000, 217 : 179 - 179
  • [46] Vertebrobasilar junction aneurysms associated with fenestration: Experience of five cases treated with Guglielmi detachable coils
    Yoon, SM
    Chun, YI
    Kwon, Y
    Kwun, BD
    [J]. SURGICAL NEUROLOGY, 2004, 61 (03): : 248 - 254
  • [47] Endovascular treatment of ruptured, peripheral cerebral aneurysms: Parent artery occlusion with short Guglielmi detachable coils
    Cloft, HJ
    Kallmes, DF
    Jensen, ME
    Lanzino, G
    Dion, JE
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (02) : 308 - 310
  • [48] Clinical and angiographic outcomes, with treatment data, for patients with cerebral aneurysms treated with Guglielmi detachable coils: A single-center experience
    Kuether, TA
    Nesbit, GM
    Barnwell, SL
    [J]. NEUROSURGERY, 1998, 43 (05) : 1016 - 1023
  • [49] MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils
    Hartman, J
    Nguyen, T
    Larsen, D
    Teitelbaum, GP
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (03) : 497 - 501
  • [50] Endovascular treatment of multiple intracranial aneurysms by using Guglielmi detachable coils
    Solander, S
    Ulhoa, A
    Viñuela, F
    Duckwiler, GR
    Gobin, YP
    Martin, NA
    Frazee, JG
    Guglielmi, G
    [J]. JOURNAL OF NEUROSURGERY, 1999, 90 (05) : 857 - 864