Selective lower body perfusion during aortic arch surgery in neonates and small children

被引:12
|
作者
Boburg, Rodrigo Sandoval [1 ]
Rosenberger, Peter [2 ]
Kling, Steffen [2 ]
Jost, Walter [1 ]
Schlensak, Christian [1 ]
Magunia, Harry [2 ]
机构
[1] Eberhard Karls Univ Tubingen, Univ Hosp Tubingen, Dept Thorac & Cardiovasc Surg, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Eberhard Karls Univ Tubingen, Univ Hosp Tubingen, Dept Anaesthesiol & Intens Care Med, Tubingen, Germany
来源
PERFUSION-UK | 2020年 / 35卷 / 07期
关键词
congenital cardiac surgery; perfusion; organ protection; ANTEGRADE CEREBRAL PERFUSION; ACUTE KIDNEY INJURY; RECONSTRUCTION;
D O I
10.1177/0267659119896890
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Aortic arch reconstruction surgery represents a challenge for the medical personnel involved in treatment. Along the years, the perfusion strategies for aortic arch reconstruction have evolved from deep hypothermic cardiac arrest to antegrade cerebral perfusion with moderate hypothermia, and recently to a combined cerebral and lower body perfusion with moderate hypothermia. To achieve a lower body perfusion, several cannulation strategies have been described. In this study, we investigated the feasibility of utilizing an arterial sheath introduced in the femoral artery to achieve an effective lower body perfusion. Methods: We included patients who underwent an aortic arch reconstruction surgery with a lower body perfusion, from January 2017 to June 2019. To achieve a lower body perfusion, a three-way stopcock was connected to the arterial line, where one end was connected to the central cannulation for cerebral perfusion and the other to an arterial sheath that was introduced through the femoral artery. A total of 25 patients were included. Peri- and postoperative lactate and creatinine levels and signs of malperfusion were recorded. Results: During the reperfusion phase, after selective perfusion ended none of the patients showed a significant increase in lactate, creatinine, and liver enzyme levels. After 24 hours, there were no signs of an acute kidney injury, femoral vessel injury, or limb malperfusion. Conclusion: These findings show that a sufficient lower body perfusion through an arterial sheath placed in the femoral artery for aortic arch reconstruction can be achieved. This approach caused no complications related to the arterial sheath during the early postoperative period and is an easy way to maintain perfusion of systemic organs.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 50 条
  • [21] Selective antegrade cerebral perfusion during aortic arch surgery confers survival and neuroprotective advantages
    Shihata, Mohammad
    Mittal, Rohan
    Senthilselvan, A.
    Ross, David
    Koshal, Arvind
    Mullen, John
    MacArthur, Roderick
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (04): : 948 - 952
  • [22] Continuous cerebral and myocardial selective perfusion in neonatal aortic arch surgery
    Maminirina, Pierre
    Pavy, Carine
    Bourgoin, Pierre
    Baron, Olivier
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (11) : 2920 - 2926
  • [23] Perfusion During Aortic Arch Surgery-Keep it Physiologic!
    Grieshaber, Philippe
    Farag, Mina
    Fonseca-Escalante, Elizabeth
    Loukanov, Tsvetomir
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2024, 15 (02) : 251 - 251
  • [24] Whole-Body Perfusion in Neonates and Infants Undergoing Aortic Arch Surgery-Working Towards the New Standard
    Boburg, Rodrigo Sandoval
    Doll, Isabelle
    Rustenbach, Christian Joerg
    Berger, Rafal
    Jost, Walter
    Magunia, Harry
    Nordmeyer, Johannes
    Michel, Joerg
    Schlensak, Christian
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (20)
  • [25] Aortic balloon occlusion catheter with perfusion lumen for protection of lower body during distal anastomosis in aortic arch repair
    Takagi, H
    Mori, Y
    Iwata, H
    Umeda, Y
    Matsuno, Y
    Hirose, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (05): : 1006 - 1008
  • [26] Continuous cerebral and myocardial perfusion during aortic arch repair in neonates and infants
    Kotani, Yasuhiro
    Ishino, Kozo
    Kasahara, Shingo
    Yoshizumi, Ko
    Honjo, Osami
    Kawada, Masaaki
    Sano, Shunji
    ASAIO JOURNAL, 2006, 52 (05) : 536 - 538
  • [27] Simultaneous upper and lower body perfusion using hypothermia during thoracoabdominal aortic surgery
    Yuya Kise
    Yukio Kuniyoshi
    Mizuki Ando
    Keita Miyaishi
    Shotaro Higa
    Tatuya Maeda
    Moriyasu Nakaema
    Hitoshi Inafuku
    Kojiro Furukawa
    Journal of Cardiothoracic Surgery, 18
  • [28] Simultaneous upper and lower body perfusion using hypothermia during thoracoabdominal aortic surgery
    Kise, Yuya
    Kuniyoshi, Yukio
    Ando, Mizuki
    Miyaishi, Keita
    Higa, Shotaro
    Maeda, Tatuya
    Nakaema, Moriyasu
    Inafuku, Hitoshi
    Furukawa, Kojiro
    JOURNAL OF CARDIOTHORACIC SURGERY, 2023, 18 (01)
  • [29] Changing body temperature during aortic arch surgery
    Minatoya, Kenji
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (06): : 1570 - 1571
  • [30] Comparison of cases with and without additional lower body perfusion in newborns undergoing aortic arch reconstruction with antegrade selective cerebral perfusion method
    Kilic, Yigit
    Selcuk, Arif
    Korun, Oktay
    Ceyda, Hasan
    Cicek, Murat
    Yurdakok, Okan
    Altin, Firat
    Erdem, Hasan
    Aydemir, Numan Ali
    Sasmazel, Ahmet
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 30 (02): : 192 - 198