Basal cell carcinoma invasion depth determined with 30 and 75 MHz high-frequency ultrasound and histopathology - a comparative study

被引:14
|
作者
Khlebnikova, Albina [1 ]
Molochkov, Vladimir [1 ]
Selezneva, Elena [1 ]
Belova, Lyubov [1 ]
Bezugly, Artur [2 ]
Sedova, Tatiana [3 ]
Molochkov, Anton [1 ]
机构
[1] MF Vladimirsky Moscow Reg Sci Res Clin Inst, Sci Pract Ctr Dermatovenerol & Cosmetol, Moscow, Russia
[2] Acad Postgrad Educ Fed State Budgetary Inst Fed S, Fed Sci & Clin Ctr Specialized Med Assistance & M, Fed Med Biol Agcy, Moscow, Russia
[3] EA Vagner Perm State Med Univ, Moscow, Russia
关键词
basal cell carcinoma (BCC); high-frequency ultrasound skin imaging; micromorphological measurement; HIGH-RESOLUTION ULTRASOUND; NONMELANOMA SKIN-CANCER; PREOPERATIVE ASSESSMENT; PHOTODYNAMIC THERAPY; TUMOR THICKNESS; MANAGEMENT; DIAGNOSIS; RISK;
D O I
10.11152/mu-2233
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: To compare the depth spread of basal cell carcinoma (BCC) measured by histological examination and high-frequencv ultrasound (HFUS) imaging with 30-MHz and 75-MHz probes. Materials and methods: HFUS skin imaging was used to examine 27 BCCs. A specialized high-resolution digital ultrasound imaging system DUB CUM GmbH, Germany) with 75-MHz and 30-MHz probes was used. After HFUS scanning, the BCCs biopsy samples were collected by punch biopsy or surgical excision for the morphological examination. Based on the histomorphology results obtained, the tumors were divided into thin (<= 1 mm invasion depth) and thick (>1 mm invasion depth). Each BCC spread depth was measured during the HFUS examination with 75-MHz and 30-MHZ ultrasound probes and morphological examination. Results: Thin BCCs average invasion depth measured histologically was 0.494 +/- 0.212 mm. Its average depth obtained with HFU examination with 75-MHz and 30-MHz probes was 0.591 +/- 0.265 and 0.734 +/- 0.123 mm, respectively. High, statistically significant correlation between the histological and 75 MHz HFU measurements was obtained (r=0.870). The correlation was weak (r=0.290) when using a 30 MHz transducer. The average thick BCC invasion depth values obtained with the histological examination and 30 MHz HFUS scanning was 1.845 +/- 0.718 mm and 1.995 +/- 0.699 mm, respectively. High, statistically significant (r=0.951) correlation between the thick BCC spread depth measured with 30 MHz transducer and histomorphological examination was obtained. Conclusions: In cases of BCCs with thickness of <= 1 nm, there was a high correlation (r=0.870) of the tumor spread depth between micromorphological measurements and the results obtained using a 75 MHz transducer and in cases of BCCs with thickness of> 1 mm, a very high correlation (=0.951) of the tumor spread depth was observed between histomorphometry and 30 MHz transducer measurements.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [21] The use of high-frequency ultrasound in the evaluation of superficial and nodular basal cell carcinomas
    Desai, Tejas D.
    Desai, Alpesh D.
    Horowitz, David C.
    Kartono, Francisca
    Wahl, Twalla
    DERMATOLOGIC SURGERY, 2007, 33 (10) : 1220 - 1226
  • [22] Prevalence and risk factors for high-frequency basal cell carcinoma in the United States
    Chiang, Audris
    Solis, Daniel C.
    Rogers, Howard
    Sohn, Grace K.
    Cho, Hyunje G.
    Saldanha, Gillian
    Lapidus, David
    Li, Shufeng
    Sarin, Kavita Y.
    Tang, Jean Y.
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2021, 84 (05) : 1493 - 1495
  • [23] Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound (30/45MHZ) System
    Touma, Marlin
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (135):
  • [24] High-frequency duplex ultrasound imaging system for biomedical applications using 30 MHz linear arrays
    Xu, Xiaochen
    Zhang, Lequan
    Sun, Lei
    Yen, Jesse T.
    Cannata, Jonathan M.
    Shung, K. Kirk
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 335 - 338
  • [25] High-frequency ultrasound: an essential non-invasive tool for the pre-therapeutic assessment of basal cell carcinoma
    Bungardean, Raluca-Maria
    Serbanescu, Mircea-Sebastian
    Colosi, Horatiu Alexandru
    Crisan, Maria
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2021, 62 (02): : 545 - 551
  • [26] Dermoscopy, reflectance confocal microscopy, and high-frequency ultrasound for the noninvasive diagnosis of morphea-form basal cell carcinoma
    Zhang, Li-Wen
    Shen, Xue
    Fu, Li-Xin
    Meng, Hui-Min
    Lu, Yong-Hong
    Chen, Tao
    Xu, Rong-Hua
    SKIN RESEARCH AND TECHNOLOGY, 2022, 28 (05) : 766 - 768
  • [27] Assessment of Basal Cell Carcinoma Using Dermoscopy and High Frequency Ultrasound Examination
    Halip, Ioana-Alina
    Vata, Dan
    Statescu, Laura
    Salahoru, Paul
    Patrascu, Adriana Ionela
    Temelie Olinici, Doinita
    Tarcau, Bogdan
    Popescu, Ioana-Adriana
    Mocanu, Madalina
    Constantin, Anne-Marie
    Crisan, Maria
    Brihan, Ilarie
    Nicolescu, Alin Codrut
    Gheuca-Solovastru, Laura
    DIAGNOSTICS, 2022, 12 (03)
  • [29] Efficacy of high-frequency ultrasound probes for the preoperative staging of invasion depth in flat and depressed colorectal tumors
    Saitoh, Y
    Obara, T
    Einami, K
    Nomura, M
    Taruishi, M
    Ayabe, T
    Ashida, T
    Shibata, Y
    Kohgo, Y
    GASTROINTESTINAL ENDOSCOPY, 1996, 44 (01) : 34 - 39
  • [30] Comparative study of methods to determine depth of invasion in vulvar squamous cell carcinoma
    Ostler, D. A.
    Malpica, A.
    Sun, C. C.
    Perna, A. G.
    Diwan, A. H.
    Lazan, A. J.
    Deavers, M. T.
    Prieto, V. G.
    LABORATORY INVESTIGATION, 2008, 88 : 216A - 217A