Basal cell carcinoma invasion depth determined with 30 and 75 MHz high-frequency ultrasound and histopathology - a comparative study

被引:14
|
作者
Khlebnikova, Albina [1 ]
Molochkov, Vladimir [1 ]
Selezneva, Elena [1 ]
Belova, Lyubov [1 ]
Bezugly, Artur [2 ]
Sedova, Tatiana [3 ]
Molochkov, Anton [1 ]
机构
[1] MF Vladimirsky Moscow Reg Sci Res Clin Inst, Sci Pract Ctr Dermatovenerol & Cosmetol, Moscow, Russia
[2] Acad Postgrad Educ Fed State Budgetary Inst Fed S, Fed Sci & Clin Ctr Specialized Med Assistance & M, Fed Med Biol Agcy, Moscow, Russia
[3] EA Vagner Perm State Med Univ, Moscow, Russia
关键词
basal cell carcinoma (BCC); high-frequency ultrasound skin imaging; micromorphological measurement; HIGH-RESOLUTION ULTRASOUND; NONMELANOMA SKIN-CANCER; PREOPERATIVE ASSESSMENT; PHOTODYNAMIC THERAPY; TUMOR THICKNESS; MANAGEMENT; DIAGNOSIS; RISK;
D O I
10.11152/mu-2233
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: To compare the depth spread of basal cell carcinoma (BCC) measured by histological examination and high-frequencv ultrasound (HFUS) imaging with 30-MHz and 75-MHz probes. Materials and methods: HFUS skin imaging was used to examine 27 BCCs. A specialized high-resolution digital ultrasound imaging system DUB CUM GmbH, Germany) with 75-MHz and 30-MHz probes was used. After HFUS scanning, the BCCs biopsy samples were collected by punch biopsy or surgical excision for the morphological examination. Based on the histomorphology results obtained, the tumors were divided into thin (<= 1 mm invasion depth) and thick (>1 mm invasion depth). Each BCC spread depth was measured during the HFUS examination with 75-MHz and 30-MHZ ultrasound probes and morphological examination. Results: Thin BCCs average invasion depth measured histologically was 0.494 +/- 0.212 mm. Its average depth obtained with HFU examination with 75-MHz and 30-MHz probes was 0.591 +/- 0.265 and 0.734 +/- 0.123 mm, respectively. High, statistically significant correlation between the histological and 75 MHz HFU measurements was obtained (r=0.870). The correlation was weak (r=0.290) when using a 30 MHz transducer. The average thick BCC invasion depth values obtained with the histological examination and 30 MHz HFUS scanning was 1.845 +/- 0.718 mm and 1.995 +/- 0.699 mm, respectively. High, statistically significant (r=0.951) correlation between the thick BCC spread depth measured with 30 MHz transducer and histomorphological examination was obtained. Conclusions: In cases of BCCs with thickness of <= 1 nm, there was a high correlation (r=0.870) of the tumor spread depth between micromorphological measurements and the results obtained using a 75 MHz transducer and in cases of BCCs with thickness of> 1 mm, a very high correlation (=0.951) of the tumor spread depth was observed between histomorphometry and 30 MHz transducer measurements.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [1] High-frequency (22-MHz) ultrasound for assessing the depth of basal cell carcinoma invasion
    Barcaui, Elisa de Oliveira
    Pires Carvalho, Antonio Carlos
    Valiante, Paulo Marcos
    Pineiro-Maceira, Juan
    Barcaui, Carlos Baptista
    SKIN RESEARCH AND TECHNOLOGY, 2021, 27 (05) : 676 - 681
  • [2] Basal cell carcinoma and squamous cell carcinoma: Comparison of high-frequency ultrasound and pathology
    Valian, Sepideh Keshavarz
    Khorasanizadeh, Faezeh
    Kamyab, Kambiz
    Nourazar, Sadra
    Montazeri, Sahar
    Azizpour, Arghavan
    SKIN RESEARCH AND TECHNOLOGY, 2024, 30 (08)
  • [3] Ex Vivo High-Frequency Ultrasound for Assessment of Basal Cell Carcinoma
    Vilas-Sueiro, Alejandro
    Alfageme, Fernando
    Salgueero, Irene
    De las Heras, Cristina
    Roustan, Gaston
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (02) : 529 - 531
  • [4] Beyond 30 MHz - Applications of high-frequency ultrasound imaging
    Lockwood, GR
    Turnbull, DH
    Christopher, DA
    Foster, FS
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 60 - 71
  • [5] High-frequency ultrasound for differentiation between high-risk basal cell carcinoma and cutaneous squamous cell carcinoma
    Chen, Zi-Tong
    Yan, Jian-Na
    Zhu, An-Qi
    Wang, Li-Fan
    Wang, Qiao
    Li, Liang
    Guo, Le-Hang
    Li, Xiao-Long
    Xu, Hui-Xiong
    SKIN RESEARCH AND TECHNOLOGY, 2022, 28 (03) : 410 - 418
  • [6] Can High-Frequency Skin Ultrasound Be Used for the Diagnosis and Management of Basal Cell Carcinoma?
    Hernandez, C.
    del Boz, J.
    de Troya, M.
    ACTAS DERMO-SIFILIOGRAFICAS, 2014, 105 (02): : 107 - 111
  • [7] Evaluation of Depth of Invasion in Oral Squamous Cell Carcinoma with Ultra-High Frequency Ultrasound: A Preliminary Study
    Izzetti, Rossana
    Nisi, Marco
    Gennai, Stefano
    Oranges, Teresa
    Crocetti, Laura
    Caramella, Davide
    Graziani, Filippo
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [8] High-frequency ultrasound associated with dermoscopy in pre-operative evaluation of basal cell carcinoma
    Barcaui, Elisa de Oliveira
    Valiante, Paulo Marcos N.
    Pires Carvalho, Antonio Carlos
    Barcaui, Carlos Baptista
    ANAIS BRASILEIROS DE DERMATOLOGIA, 2014, 89 (05) : 828 - 831
  • [9] High-frequency ultrasound features of basal cell carcinoma and its association with histological recurrence risk
    Wang, Shi-Qi
    Liu, Jie
    Zhu, Qing-Li
    Zhao, Chen-Yang
    Qu, Tao
    Li, Feng
    Wortsman, Ximena
    Jin, Hong-Zhong
    CHINESE MEDICAL JOURNAL, 2019, 132 (17) : 2021 - 2026
  • [10] High-frequency ultrasound features of basal cell carcinoma and its association with histological recurrence risk
    Wang Shi-Qi
    Liu Jie
    Zhu Qing-Li
    Zhao Chen-Yang
    Qu Tao
    Li Feng
    Wortsman Ximena
    Jin Hong-Zhong
    中华医学杂志英文版, 2019, 132 (17) : 2021 - 2026