共 50 条
Tenon Cyst Patch Graft for Ahmed Glaucoma Valve Tube Exposure: Case Series Report
被引:4
|作者:
Alvarez-Ascencio, Daniela
[1
]
Lazcano-Gomez, Gabriel
[1
]
Flores-Reyes, Elsa
[2
]
Duenas-Angeles, Karla
[2
]
Jimenez-Roman, Jesus
[1
]
Kahook, Malik Y.
[3
]
机构:
[1] Asociac Evitar Ceguera Mexico APEC, Dept Glaucoma, Vicente Garcia Torres 46, Mexico City 04030, DF, Mexico
[2] Inst Oftalmol Conde Valenciana, Dept Glaucoma, Mexico City, DF, Mexico
[3] Univ Colorado, Dept Ophthalmol, Aurora, CO USA
关键词:
glaucoma drainage device;
erosion;
wound repair;
autograft;
Tenon cyst;
CLINICAL-EXPERIENCE;
IMPLANTATION;
SHUNT;
MANAGEMENT;
MEMBRANE;
REVISION;
SURGERY;
D O I:
10.1097/IJG.0000000000001776
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
Purpose: To report our experience using a Tenon cyst autograft in the management of tube exposure post Ahmed glaucoma valve (AGV) implantation. Methods: This is a retrospective case series. Results: Four patients who underwent tube exposure repair using Tenon cyst autograft were identified in our tertiary care center. The duration between initial AGV implantation and tube exposure ranged between 3 and 36 months with a mean of 16 months (+/- 14.35 mo). All patients were followed postoperatively for a range of 4 to 24 months with a mean of 11.75 months (+/- 9.03 o) and all remain exposure free at last follow-up. Conclusion: The use of a Tenon cyst autograft for the surgical repair of a tube exposure is valuable, as it involves using autologous scar tissue that is available in eyes that have undergone AGV implantation. The patch autograft is technically easy to harvest, and represents a significantly lower cost when compared with other available options.
引用
收藏
页码:E367 / E371
页数:5
相关论文