Structural-Thermal-Optical-Performance (STOP) Model Development and Analysis of a Field-widened Michelson Interferometer

被引:4
|
作者
Scola, Salvatore J. [1 ]
Osmundsen, James F. [1 ]
Murchison, Luke S. [1 ]
Davis, Warren T. [1 ]
Fody, Joshua M. [1 ]
Boyer, Charles M. [1 ]
Cook, Anthony L. [1 ]
Hostetler, Chris A. [1 ]
Seaman, Shane T. [1 ]
Miller, Ian J. [2 ]
Welch, Wayne C. [3 ]
Kosmer, Adam R. [3 ]
机构
[1] NASA, Langley Res Ctr, Hampton, VA 23681 USA
[2] LightMachinery, Nepean, ON K2E 7L2, Canada
[3] Welch Mech Designs, Belcamp, MD 21017 USA
关键词
STOP analysis; structural thermal optical performance model; Michelson interferometer; Comet software; HSRL; NASA Langley; SPECTRAL-RESOLUTION LIDAR;
D O I
10.1117/12.2061041
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An integrated Structural-Thermal-Optical-Performance (STOP) model was developed for a field-widened Michelson interferometer which is being built and tested for the High Spectral Resolution Lidar (HSRL) project at NASA Langley Research Center (LaRC). The performance of the interferometer is highly sensitive to thermal expansion, changes in refractive index with temperature, temperature gradients, and deformation due to mounting stresses. Hand calculations can only predict system performance for uniform temperature changes, under the assumption that coefficient of thermal expansion (CTE) mismatch effects are negligible. An integrated STOP model was developed to investigate the effects of design modifications on the performance of the interferometer in detail, including CTE mismatch, and other three-dimensional effects. The model will be used to improve the design for a future spaceflight version of the interferometer. The STOP model was developed using the Comet SimApp (TM) Authoring Workspace which performs automated integration between Pro-Engineer (R), Thermal Desktop (R), MSC Nastran (TM), SigFit (TM), Code V (TM), and MATLAB (R). This is the first flight project for which LaRC has utilized Comet, and it allows a larger trade space to be studied in a shorter time than would be possible in a traditional STOP analysis. This paper describes the development of the STOP model, presents a comparison of STOP results for simple cases with hand calculations, and presents results of the correlation effort to bench-top testing of the interferometer. A trade study conducted with the STOP model which demonstrates a few simple design changes that can improve the performance seen in the lab is also presented.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Structural, thermal, and optical performance analysis applied to subsystems of the European Extremely Large Telescope
    Holzloehner, Ronald
    Kellerer, Aglae
    Lampater, Ulrich
    Lewis, Steffan
    Zanoni, Carlo
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2022, 8 (02)
  • [42] STOP model development and analysis of an optical collimation system for a tactical high-energy laser weapon
    Lyu, Chenyang
    Zhan, Renjun
    APPLIED OPTICS, 2021, 60 (13) : 3596 - 3603
  • [43] Development of a Numerical Model Designed to Calculate the Temperature Field and Thermal Stresses in Structural Elements of Aircrafts
    Kuzenov, V. V.
    Shumaev, V. V.
    Dobrynina, A. O.
    FLUID DYNAMICS, 2022, 57 (SUPPL 1) : S170 - S180
  • [44] Development of a Numerical Model Designed to Calculate the Temperature Field and Thermal Stresses in Structural Elements of Aircrafts
    V. V. Kuzenov
    V. V. Shumaev
    A. O. Dobrynina
    Fluid Dynamics, 2022, 57 : S170 - S180
  • [45] Electrical, thermal and structural performance of a cooled PV module: Transient analysis using a multiphysics model
    Siddiqui, M. U.
    Arif, A. F. M.
    APPLIED ENERGY, 2013, 112 : 300 - 312
  • [46] A multi-field coupling model for the magnetic-thermal-structural analysis in the electromagnetic rail launch
    Zhang, Bao
    Kou, Yong
    Jin, Ke
    Zheng, Xiaojing
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2021, 519
  • [47] Research on thermal-structural-optical multi-field coupling modeling and concentrating performance predication of solar dish system
    Yan, Jian
    Peng, Youduo
    Yu, Jiahuan
    Wang, Minhui
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2015, 51 (14): : 138 - 151
  • [48] Thermal-mechanical performance analysis of parabolic trough receivers under various optical errors based on coupled optical-thermal-stress model
    Liu, Shuaishuai
    Yang, Bin
    Zhi, Yuan
    Yu, Xiaohui
    RENEWABLE ENERGY, 2023, 210 : 687 - 700
  • [49] Development of a Model for Performance Analysis of a Honeycomb Thermal Energy Storage for Solar Power Microturbine Applications
    Iaria, Davide
    Zhou, Xin
    Al Zaili, Jafar
    Zhang, Qiang
    Xiao, Gang
    Sayma, Abdulnaser
    ENERGIES, 2019, 12 (20)
  • [50] Multi-Physical Intelligent Analysis of the Thermal-Structural-Optical Coupling for Mirror Based on Surrogate Model
    Li, Wenxiong
    Shen, Junli
    Lu, Zhenyu
    Men, Shudong
    Wu, Qingwen
    IEEE ACCESS, 2025, 13 : 14113 - 14121