Atrioventricular conduction in PM recipients after transcatheter aortic valve implantation: Implications using Wenckebach point measurement

被引:3
|
作者
Pelargonio, Gemma [1 ,2 ]
Scacciavillani, Roberto [1 ,3 ]
Donisi, Luca [1 ]
Narducci, Maria Lucia [1 ]
Aurigemma, Cristina [1 ]
Pinnacchio, Gaetano [1 ]
Bencardino, Gianluigi [1 ]
Perna, Francesco [1 ]
Spera, Francesco Raffaele [1 ]
Comerci, Gianluca [1 ]
Ruscio, Eleonora [1 ]
Romagnoli, Enrico [1 ]
Crea, Filippo [1 ,2 ]
Burzotta, Francesco [1 ,2 ]
Trani, Carlo [1 ,2 ]
机构
[1] Fdn Policlin Univ Agostino Gemelli IRCCS, Dept Cardiovasc Sci, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Cardiol Inst, Rome, Italy
[3] Fdn Policlin Univ Agostino Gemelli IRCCS, Rome, Italy
来源
关键词
Wenckebach point; personalized medicine; pacing; transcatheter aortic valve implantation (TAVI); atrioventricular conduction; IN-HOSPITAL MORTALITY; PACEMAKER IMPLANTATION; REPLACEMENT; PREDICTORS; DISTURBANCES; MANAGEMENT;
D O I
10.3389/fcvm.2022.904828
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrioventricular (AV) conduction disturbances requiring permanent pacemaker implantation (PPI) are a common complication after transcatheter aortic valve implantation (TAVI). However, a significant proportion of patients might recover AV conduction at follow-up. ObjectivesThe aim of our study was to evaluate the recovery of AV conduction by determination through Wenckebach point in patients with PPI and therefore identify patients who could benefit from device reprogramming to avoid unnecessary RV pacing. MethodsWe enrolled 43 patients that underwent PM implantation after TAVI at our Department from January 2018 to January 2021. PM interrogation was performed at follow-up and patients with native spontaneous rhythm were further assessed for AV conduction through WP determination. ResultsA total of 43 patients requiring a PM represented the final study population, divided in patients with severely impaired AV conduction (no spontaneous valid rhythm or WP < 100; 26) and patients with valid AV conduction (WP >= 100; 17). In the first group patients had a significantly higher number of intraprocedural atrioventricular block (AVB) (20 vs. 1, p < 0.005), showed a significant higher implantation depth in LVOT (7.7 +/- 2.2 vs. 4.4 +/- 1.1, p < 0.05) and lower Delta MSID (-0.28 +/- 3 vs. -3.94 +/- 2, p < 0.05). ConclusionAV conduction may recover in a significant proportion of patients. In our study, valve implantation depth in the LVOT and intraprocedural AV block are associated with severely impaired AV conduction. Regular PM interrogation and reprogramming are required to avoid unnecessary permanent right ventricular stimulation in patients with AV conduction recovery.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Electrophysiological Evaluation of Atrioventricular Conduction Disturbances in Transcatheter Aortic Valve Implantation With Edwards SAPIEN Prosthesis
    Eksik, Abdurrahman
    Gul, Mehmet
    Uyarel, Huseyin
    Surgit, Ozgur
    Yildirim, Aydin
    Uslu, Nevzat
    Aksu, Huseyin
    Turen, Selahattin
    Uzun, Fazih
    Satilmisoglu, Hulusi
    Erol, Mustafa Kemal
    Bakir, Ihsan
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (06): : 305 - 309
  • [32] Electrophysiological evaluation of atrioventricular conduction disturbances in transcatheter aortic valve implantation with edwards sapien prosthesis
    Eksik, A.
    Gul, M.
    Uyarel, H.
    Surgit, O.
    Yildirim, A.
    Uslu, N.
    Aksu, H.
    Satilmisoglu, H.
    Erol, M. K.
    Bakir, I.
    EUROPEAN HEART JOURNAL, 2013, 34 : 987 - 987
  • [33] Effect of concomitant atrioventricular valve regurgitation on the outcome after transcatheter aortic-valve implantation
    Drakopoulou, M.
    Karmpalioti, M.
    Simopoulou, C.
    Oikonomou, G.
    Apostolos, A.
    Toskas, P.
    Soulaidopoulos, S.
    Stathogiannis, K.
    Synetos, A.
    Latsios, G.
    Tsioufis, C.
    Toutouzas, K.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1678 - 1678
  • [34] Histological pattern of penetrating His bundle division: implications for atrioventricular conduction damage during and following transcatheter aortic valve implantation
    Cabrera, J. A.
    Porta-Sanchez, A.
    Nunez Pernas, D.
    Rubio, J. M.
    Navarro, F.
    Salvador-Montanes, O.
    Macias, Y.
    Nevado-Medina, J.
    Sanchez-Quintana, D.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3695 - 3695
  • [35] Recovery of atrioventricular conduction in patients with heart block after transcatheter aortic valve replacement
    Raelson, Colin A.
    Gabriels, James
    Ruan, Jonathan
    Ip, James E.
    Thomas, George
    Liu, Christopher F.
    Cheung, Jim W.
    Lerman, Bruce B.
    Patel, Apoor
    Markowitz, Steven M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (10) : 1196 - 1202
  • [36] Location and Severity of Aortic Valve Calcium and Implications for Aortic Regurgitation After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Ng, Arnold C. T.
    Schuijf, Joanne D.
    van der Kley, Frank
    Colli, Andrea
    Palmen, Meindert
    de Weger, Arend
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Delgado, Victoria
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (10): : 1470 - 1477
  • [37] Volume and distribution of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation
    Samim, Mariam
    Agostoni, Pierfrancesco
    Nijhoff, Freek
    Stella, Pieter R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B195 - B195
  • [38] Prognostic impact of intraventricular conduction disturbances after transcatheter aortic valve implantation
    Almeida, J.
    Dias, T.
    Guerreiro, C.
    Pereira, E.
    Caeiro, D.
    Oliveira, M.
    Goncalves, H.
    Rodrigues, A.
    Ribeiro, J.
    Primo, J.
    Braga, P.
    Gama, V.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1074 - 1074
  • [39] Conduction recovery following pacemaker implantation after transcatheter aortic valve replacement
    Kaplan, Rachel M.
    Yadlapati, Ajay
    Cantey, Eric P.
    Passman, Rod S.
    Gajjar, Mark
    Knight, Bradley P.
    Sweis, Ranya
    Ricciardi, Mark J.
    Pham, Duc T.
    Churyla, Andrei
    Malaisrie, S. Chris
    Davidson, Charles J.
    Flaherty, James D.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (02): : 146 - 152
  • [40] Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management
    Wilczek, Krzysztof
    Regula, Rafal
    Bujak, Kamil
    Chodor, Piotr
    Dlugaszek, Michal
    Gasior, Mariusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (03): : 203 - 211