Atrioventricular conduction in PM recipients after transcatheter aortic valve implantation: Implications using Wenckebach point measurement

被引:3
|
作者
Pelargonio, Gemma [1 ,2 ]
Scacciavillani, Roberto [1 ,3 ]
Donisi, Luca [1 ]
Narducci, Maria Lucia [1 ]
Aurigemma, Cristina [1 ]
Pinnacchio, Gaetano [1 ]
Bencardino, Gianluigi [1 ]
Perna, Francesco [1 ]
Spera, Francesco Raffaele [1 ]
Comerci, Gianluca [1 ]
Ruscio, Eleonora [1 ]
Romagnoli, Enrico [1 ]
Crea, Filippo [1 ,2 ]
Burzotta, Francesco [1 ,2 ]
Trani, Carlo [1 ,2 ]
机构
[1] Fdn Policlin Univ Agostino Gemelli IRCCS, Dept Cardiovasc Sci, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Cardiol Inst, Rome, Italy
[3] Fdn Policlin Univ Agostino Gemelli IRCCS, Rome, Italy
来源
关键词
Wenckebach point; personalized medicine; pacing; transcatheter aortic valve implantation (TAVI); atrioventricular conduction; IN-HOSPITAL MORTALITY; PACEMAKER IMPLANTATION; REPLACEMENT; PREDICTORS; DISTURBANCES; MANAGEMENT;
D O I
10.3389/fcvm.2022.904828
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrioventricular (AV) conduction disturbances requiring permanent pacemaker implantation (PPI) are a common complication after transcatheter aortic valve implantation (TAVI). However, a significant proportion of patients might recover AV conduction at follow-up. ObjectivesThe aim of our study was to evaluate the recovery of AV conduction by determination through Wenckebach point in patients with PPI and therefore identify patients who could benefit from device reprogramming to avoid unnecessary RV pacing. MethodsWe enrolled 43 patients that underwent PM implantation after TAVI at our Department from January 2018 to January 2021. PM interrogation was performed at follow-up and patients with native spontaneous rhythm were further assessed for AV conduction through WP determination. ResultsA total of 43 patients requiring a PM represented the final study population, divided in patients with severely impaired AV conduction (no spontaneous valid rhythm or WP < 100; 26) and patients with valid AV conduction (WP >= 100; 17). In the first group patients had a significantly higher number of intraprocedural atrioventricular block (AVB) (20 vs. 1, p < 0.005), showed a significant higher implantation depth in LVOT (7.7 +/- 2.2 vs. 4.4 +/- 1.1, p < 0.05) and lower Delta MSID (-0.28 +/- 3 vs. -3.94 +/- 2, p < 0.05). ConclusionAV conduction may recover in a significant proportion of patients. In our study, valve implantation depth in the LVOT and intraprocedural AV block are associated with severely impaired AV conduction. Regular PM interrogation and reprogramming are required to avoid unnecessary permanent right ventricular stimulation in patients with AV conduction recovery.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Atrioventricular Conduction After Transcatheter Aortic Valve Implantation and Surgical Aortic Valve Replacement
    Roten, Laurent
    Stortecky, Stefan
    Scarcia, Flavio
    Kadner, Alexander
    Tanner, Hildegard
    Delacretaz, Etienne
    Meier, Bernhard
    Windecker, Stephan
    Carrel, Thierry
    Wenaweser, Peter
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (10) : 1115 - 1122
  • [2] Atrioventricular Conduction Intervals Before and After Transcatheter Aortic Valve Implantation
    Romero, Miguel
    Segura, Jose
    Suarez de Lezo, Javier
    Pan, Manuel
    Ojeda, Soledad
    Mazuelos, Francisco
    Suarez de Lezo, Jose
    CIRCULATION, 2011, 124 (21)
  • [3] Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation
    Lopez-Aguilera, Jose
    Segura Saint-Gerons, Jose Maria
    Mazuelos Bellido, Francisco
    Suarez de Lezo, Javier
    Ojeda Pineda, Soledad
    Pan Alvarez-Ossorio, Manuel
    Romero Moreno, Miguel Angel
    Pavlovic, Djordje
    Espejo Perez, Simona
    Suarez de Lezo, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (01): : 28 - 36
  • [4] Incidence and Predictors of Atrioventricular Conduction Impairment After Transcatheter Aortic Valve Implantation
    Roten, Laurent
    Wenaweser, Peter
    Delacretaz, Etienne
    Hellige, Gerrit
    Stortecky, Stefan
    Tanner, Hildegard
    Pilgrim, Thomas
    Kadner, Alexander
    Eberle, Balthasar
    Zwahlen, Marcel
    Carrel, Thierry
    Meier, Bernhard
    Windecker, Stephan
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (10): : 1473 - 1480
  • [5] Atrioventricular conduction disturbance after transcatheter aortic valve implantation: incidence and predictive factors
    Lefoulon, A. L.
    Jesel, L. J.
    Marzak, H. M.
    Morel, O. M.
    Ohlmann, P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 958 - 958
  • [6] Atrioventricular conduction time and permanent pacemaker therapy after transcatheter aortic valve implantation
    Takam, P. C.
    Buettner, J.
    Hoefflin, D.
    Heinke, M.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S224 - S226
  • [7] Clinical Implications of Conduction Abnormalities and Arrhythmias After Transcatheter Aortic Valve Implantation
    Robert M. A. van der Boon
    Patrick Houthuizen
    Rutger-Jan Nuis
    Nicolas M. van Mieghem
    Frits Prinzen
    Peter P. T. de Jaegere
    Current Cardiology Reports, 2014, 16
  • [8] Clinical Implications of Conduction Abnormalities and Arrhythmias After Transcatheter Aortic Valve Implantation
    van der Boon, Robert M. A.
    Houthuizen, Patrick
    Nuis, Rutger-Jan
    van Mieghem, Nicolas M.
    Prinzen, Frits
    de Jaegere, Peter P. T.
    CURRENT CARDIOLOGY REPORTS, 2014, 16 (01)
  • [9] Conduction abnormalities after transcatheter aortic valve implantation
    Karyofillis, Panagiotis
    Kostopoulou, Anna
    Thomopoulou, Sofia
    Habibi, Martha
    Livanis, Efthimios
    Karavolias, George
    Voudris, Vassilis
    JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (01) : 105 - 112
  • [10] Impact of transcatheter aortic valve implantation on atrioventricular conduction in patients with severe aortic stenosis
    Kircher, S.
    Piorkowski, C.
    Gaspar, T.
    Herbsleb, V.
    Kiuchi, K.
    Rastan, A.
    Hindricks, G.
    Mohr, F. -W.
    Schuler, G.
    Linke, A.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1111 - 1111