Deconstructing mastery in colorectal fluorescence angiography interpretation

被引:7
|
作者
Dalli, Jeffrey [1 ]
Shanahan, Sarah [1 ]
Hardy, Niall P. [1 ]
Chand, Manish [2 ]
Hompes, Roel [3 ]
Jayne, David [4 ]
Ris, Frederic [5 ]
Spinelli, Antonino [6 ,7 ]
Wexner, Steven [8 ]
Cahill, Ronan A. [1 ,9 ]
机构
[1] Univ Coll Dublin, Catherine McAuley Ctr, UCD Ctr Precis Surg, Sch Med, 21 Nelson St, Dublin D07 KX5K 7, Ireland
[2] UCL, WEISS Ctr, UCL Div Surg & Intervent Sci, London, England
[3] Univ Amsterdam, Amsterdam UMC AMC, Dept Surg, Amsterdam, Netherlands
[4] Univ Leeds, Leeds Inst Med Res, Leeds, W Yorkshire, England
[5] Geneva Univ Hosp & Med Sch, Serv Visceral Surg, Geneva, Switzerland
[6] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20090 Pieve Emanuele, MI, Italy
[7] IRCCS Humanitas Res Hosp, Via Manzoni 56, I-20089 Rozzano, MI, Italy
[8] Cleveland Clin Florida, Dept Colorectal Surg, Weston, FL 33331 USA
[9] Mater Misericordiae Univ Hosp, Dept Surg, Dublin, Ireland
关键词
Indocyanine green; Fluorescence; Angiography; Digital; Quantitative;
D O I
10.1007/s00464-022-09299-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction Indocyanine green fluorescence angiography (ICGFA) is commonly used in colorectal anastomotic practice with limited pre-training. Recent work has shown that there is considerable inconsistency in signal interpretation between surgeons with minimal or no experience versus those consciously invested in mastery of the technique. Here, we deconstruct the fluorescence signal patterns of expert-annotated surgical ICGFA videos to understand better their correlation and combine this with structured interviews to ascertain whether such interpretative capability is conscious or unconscious. Methods For fluorescence signal analysis, expert-annotated ICGFA videos (n = 24) were quantitatively interrogated using a boutique intensity tracker (IBM Research) to generate signal time plots. Such fluorescence intensity data were examined for inter-observer correlation (Intraclass Correlation Coefficients, ICC) at specific curve milestones: the maximum fluorescence signal (F-max), the times to both achieve this maximum (T-max), as well as half this maximum (T-1/2max) and the ratio between these (T-1/2/T-max). Formal tele-interview with contributing experts (n = 6) was conducted with the narrative transcripts being thematically mapped, plotted, and qualitatively analyzed. Results Correlation by mathematical measures was excellent (ICC0.9-1.0) for F-max, T-max, and T-1/2max (0.95, 0.938, and 0.925, respectively) and moderate (0.5-0.75) for T-1/2/T-max (0.729). While all experts narrated a deliberate viewing strategy, their specific dynamic signal appreciation differed in the manner of description. Conclusion Expert ICGFA users demonstrate high correlation in mathematical measures of their signal interpretation although do so tacitly. Computational quantification of expert behavior can help develop the necessary lexicon and training sets as well as computer vision methodology to better exploit ICGFA technology.
引用
收藏
页码:8764 / 8773
页数:10
相关论文
共 50 条
  • [1] Deconstructing mastery in colorectal fluorescence angiography interpretation
    Jeffrey Dalli
    Sarah Shanahan
    Niall P. Hardy
    Manish Chand
    Roel Hompes
    David Jayne
    Frederic Ris
    Antonino Spinelli
    Steven Wexner
    Ronan A. Cahill
    Surgical Endoscopy, 2022, 36 : 8764 - 8773
  • [2] Challenges in the interpretation of colorectal indocyanine green fluorescence angiography - A video vignette
    Dalli, Jeffrey
    Hardy, Niall
    Mac Aonghusa, Pol G.
    Epperlein, Jonathan P.
    Cantillon Murphy, Padraig
    Cahill, Ronan A.
    COLORECTAL DISEASE, 2021, 23 (05) : 1289 - 1290
  • [3] Fluorescence Angiography in Colorectal Resection
    Johnson, Eric K.
    Hardin, Mark O.
    Walker, Avery S.
    Hatch, Quinton
    Steele, Scott R.
    DISEASES OF THE COLON & RECTUM, 2016, 59 (01) : E1 - E4
  • [4] Intraoperative fluorescence angiography in colorectal surgery
    Carus, T.
    Pick, P.
    CHIRURG, 2019, 90 (11): : 887 - 890
  • [5] Impact of standardising indocyanine green fluorescence angiography technique for visual and quantitative interpretation on interuser variability in colorectal surgery
    Dalli, Jeffrey
    Joosten, Johanna J.
    Jindal, Abhinav
    Hardy, Niall P.
    Camilleri-Brennan, John
    Andrejevic, Predrag
    Hompes, Roel
    Cahill, Ronan A.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2024, 38 (03): : 1306 - 1315
  • [6] Impact of standardising indocyanine green fluorescence angiography technique for visual and quantitative interpretation on interuser variability in colorectal surgery
    Jeffrey Dalli
    Johanna J. Joosten
    Abhinav Jindal
    Niall P. Hardy
    John Camilleri-Brennan
    Predrag Andrejevic
    Roel Hompes
    Ronan A. Cahill
    Surgical Endoscopy, 2024, 38 : 1306 - 1315
  • [7] Deconstructing the Mechanism of Interpretation
    Soos, Amalia
    PHILOBIBLON-TRANSYLVANIAN JOURNAL OF MULTIDISCIPLINARY RESEARCH IN HUMANITIES, 2014, 19 (01): : 256 - 260
  • [8] Equivocal Effect of Intraoperative Fluorescence Angiography on Colorectal Anastomotic Leaks
    Kin, Cindy
    Vo, Hong
    Welton, Lindsay
    Welton, Mark
    DISEASES OF THE COLON & RECTUM, 2015, 58 (06) : 582 - 587
  • [9] PREDICTIVE MODEL FOR USE OF FLUORESCENCE ANGIOGRAPHY IN COLORECTAL SURGERY.
    Simon, H. L.
    de Paula, T. Reif
    Hill, A.
    Zhang, J.
    Keller, D. S.
    DISEASES OF THE COLON & RECTUM, 2021, 64 (05)
  • [10] INTRAOPERATIVE FLUORESCENCE ANGIOGRAPHY DOES NOT DECREASE COLORECTAL ANASTOMOTIC LEAK RATES
    Kin, C.
    Vo, H.
    Welton, M.
    DISEASES OF THE COLON & RECTUM, 2014, 57 (05) : E142 - E143