Deconstructing mastery in colorectal fluorescence angiography interpretation

被引:7
|
作者
Dalli, Jeffrey [1 ]
Shanahan, Sarah [1 ]
Hardy, Niall P. [1 ]
Chand, Manish [2 ]
Hompes, Roel [3 ]
Jayne, David [4 ]
Ris, Frederic [5 ]
Spinelli, Antonino [6 ,7 ]
Wexner, Steven [8 ]
Cahill, Ronan A. [1 ,9 ]
机构
[1] Univ Coll Dublin, Catherine McAuley Ctr, UCD Ctr Precis Surg, Sch Med, 21 Nelson St, Dublin D07 KX5K 7, Ireland
[2] UCL, WEISS Ctr, UCL Div Surg & Intervent Sci, London, England
[3] Univ Amsterdam, Amsterdam UMC AMC, Dept Surg, Amsterdam, Netherlands
[4] Univ Leeds, Leeds Inst Med Res, Leeds, W Yorkshire, England
[5] Geneva Univ Hosp & Med Sch, Serv Visceral Surg, Geneva, Switzerland
[6] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20090 Pieve Emanuele, MI, Italy
[7] IRCCS Humanitas Res Hosp, Via Manzoni 56, I-20089 Rozzano, MI, Italy
[8] Cleveland Clin Florida, Dept Colorectal Surg, Weston, FL 33331 USA
[9] Mater Misericordiae Univ Hosp, Dept Surg, Dublin, Ireland
关键词
Indocyanine green; Fluorescence; Angiography; Digital; Quantitative;
D O I
10.1007/s00464-022-09299-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction Indocyanine green fluorescence angiography (ICGFA) is commonly used in colorectal anastomotic practice with limited pre-training. Recent work has shown that there is considerable inconsistency in signal interpretation between surgeons with minimal or no experience versus those consciously invested in mastery of the technique. Here, we deconstruct the fluorescence signal patterns of expert-annotated surgical ICGFA videos to understand better their correlation and combine this with structured interviews to ascertain whether such interpretative capability is conscious or unconscious. Methods For fluorescence signal analysis, expert-annotated ICGFA videos (n = 24) were quantitatively interrogated using a boutique intensity tracker (IBM Research) to generate signal time plots. Such fluorescence intensity data were examined for inter-observer correlation (Intraclass Correlation Coefficients, ICC) at specific curve milestones: the maximum fluorescence signal (F-max), the times to both achieve this maximum (T-max), as well as half this maximum (T-1/2max) and the ratio between these (T-1/2/T-max). Formal tele-interview with contributing experts (n = 6) was conducted with the narrative transcripts being thematically mapped, plotted, and qualitatively analyzed. Results Correlation by mathematical measures was excellent (ICC0.9-1.0) for F-max, T-max, and T-1/2max (0.95, 0.938, and 0.925, respectively) and moderate (0.5-0.75) for T-1/2/T-max (0.729). While all experts narrated a deliberate viewing strategy, their specific dynamic signal appreciation differed in the manner of description. Conclusion Expert ICGFA users demonstrate high correlation in mathematical measures of their signal interpretation although do so tacitly. Computational quantification of expert behavior can help develop the necessary lexicon and training sets as well as computer vision methodology to better exploit ICGFA technology.
引用
收藏
页码:8764 / 8773
页数:10
相关论文
共 50 条
  • [41] Comparison of hyperspectral imaging and fluorescence angiography for the determination of the transection margin in colorectal resections—a comparative study
    Boris Jansen-Winkeln
    Isabell Germann
    Hannes Köhler
    Matthias Mehdorn
    Marianne Maktabi
    Robert Sucher
    Manuel Barberio
    Claire Chalopin
    Michele Diana
    Yusef Moulla
    Ines Gockel
    International Journal of Colorectal Disease, 2021, 36 : 283 - 291
  • [42] Intraoperative laser fluorescence angiography in colorectal surgery: a noninvasive analysis to reduce the rate of anastomotic leakage
    Stefanie Kudszus
    Christian Roesel
    Alexander Schachtrupp
    Jörg J. Höer
    Langenbeck's Archives of Surgery, 2010, 395 : 1025 - 1030
  • [43] ANGIOGRAPHY OF HAND - GUIDELINES FOR INTERPRETATION
    CALENOFF, L
    RADIOLOGY, 1972, 102 (02) : 331 - &
  • [44] INTERPRETATION OF RESULTS OF FLUORESCENT ANGIOGRAPHY
    BLAZEK, K
    SBORNIK LEKARSKY, 1970, 72 (8-9): : 202 - &
  • [45] Interpretation of renal angiography by radiologists
    Schreij, G
    de Haan, MW
    Oei, TK
    Koster, D
    de Leeuw, PW
    JOURNAL OF HYPERTENSION, 1999, 17 (12) : 1737 - 1741
  • [47] Colorectal surgeons' perspectives on the efficacy of intraoperative bowel perfusion technology with a focus on indocyanine green fluorescence angiography
    Singaravelu, Ashokkumar
    Entee, Philip D. Mc
    Boland, Patrick A.
    Moynihan, Alice
    Mccarrick, Cathleen
    Vahrmeijer, Alexander L.
    Arezzo, Alberto
    Boni, Luigi
    Hompes, Roel
    Cahill, Ronan A.
    LANGENBECKS ARCHIVES OF SURGERY, 2025, 410 (01)
  • [48] Efficacy of indocyanine green fluorescence angiography in preventing anastomotic leakage after laparoscopic colorectal cancer surgery
    Masayuki Ishii
    Atsushi Hamabe
    Kenji Okita
    Toshihiko Nishidate
    Koichi Okuya
    Akihiro Usui
    Emi Akizuki
    Tetsuta Satoyoshi
    Ichiro Takemasa
    International Journal of Colorectal Disease, 2020, 35 : 269 - 275
  • [49] The Mastery of the praise of the Master (Interpretation by Madadayo de Akira Kurosawa)
    Davila, Jorge
    SITUARTE, 2007, 1 (02): : 83 - 97
  • [50] SIMPLE INJECTOR FOR FLUORESCENCE ANGIOGRAPHY
    LAUX, U
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1976, 168 (06) : 865 - 865