Ferroelectret non-contact ultrasonic transducers

被引:47
|
作者
Bovtun, V.
Doering, J.
Bartusch, J.
Beck, U.
Erhard, A.
Yakymenko, Y.
机构
[1] Fed Inst Mat Res & Testing, D-12205 Berlin, Germany
[2] Inst Phys ASCR, Prague 18221, Czech Republic
[3] NTUU Kiev Polytech Inst, UA-03056 Kiev, Ukraine
来源
关键词
FREQUENCY-RANGE; INFLATION; NDE;
D O I
10.1007/s00339-007-4060-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT), combining strong piezoelectric response with a low density and softness, evidence their high potential for the air-coupled ultrasonic applications. The disadvantage of the low coupling factor is compensated by the extremely low acoustic impedance, which provides excellent matching to air and promises efficient sound transmission through the air-transducer interface. The influence of the electrodes on the electromechanical properties was investigated. Electron beam evaporation technology was adapted to the EMFIT films, and films with both-sided Au and Al electrodes were prepared without reducing or suppressing of the electromechanical properties. Finally, prototype transducers based on the EMFIT films were developed. In spite of the simple construction and absence of matching layers, high sensitivity of the EMFIT transducers was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging and testing with EMFIT transducers is possible.
引用
收藏
页码:737 / 743
页数:7
相关论文
共 50 条
  • [41] Non-contact ultrasonic guided wave inspection of rails
    Nguyen, Thompson V.
    Mariani, Stefano
    di Scalea, Francesco Lanza
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2014, 2014, 9064
  • [42] NON-CONTACT ULTRASONIC CHARACTERIZATION OF ANGLED SURFACE DEFECTS
    Edwards, R. S.
    Dutton, B.
    Rosli, M. H.
    Clough, A. R.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 257 - 264
  • [43] Non-Contact Interaction of Ultrasonic Wave on Laser Beam
    Muc, S.
    Gudra, T.
    Beres-Pawlik, E.
    ACTA PHYSICA POLONICA A, 2011, 120 (04) : 702 - 704
  • [44] Non-contact ultrasonic imaging for the evaluation of thermal injury
    Jones, L.
    Lee, D.
    Iranika, S.
    Vanderkam, V.
    Achauer, B.
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [45] Ultrasonic Non-Contact Analyzer: NCA-1000
    不详
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 1999, 71 (02): : 205 - 206
  • [46] Non-contact ultrasonic quality measurements of food products
    Gan, Tat Hean
    Pallav, Prakash
    Hutchins, David A.
    JOURNAL OF FOOD ENGINEERING, 2006, 77 (02) : 239 - 247
  • [47] Non-contact ultrasonic treatment of metals in a magnetic field
    Wilgen, John B.
    Kisner, Roger A.
    Jaramillo, Roger A.
    Ludtka, Gerard M.
    Mackiewicz-Ludtka, Gail
    MATERIALS PROCESSING UNDER THE INFLUENCE OF EXTERNAL FIELDS, 2007, : 145 - +
  • [48] Automated non-contact NDT by ultrasonic surface waves
    Liu, Qiang
    Piwakowski, Bogdan
    Lafhaj, Zoubeir
    Agred, Kahina
    2014 IEEE FAR EAST FORUM ON NONDESTRUCTIVE EVALUATION/TESTING (FENDT), 2014, : 79 - 83
  • [49] Acoustic Balance: Weighing in Ultrasonic Non-Contact Manipulators
    Nakahara, Jared
    Smith, Joshua R.
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (04) : 9145 - 9150
  • [50] Ultrasonic Devices for Non-Contact Intensification of Technological Processes
    V. N. Khmelev
    S. N. Tsyganok
    R. V. Barsukov
    M. V. Khmelev
    A. R. Barsukov
    Fibre Chemistry, 2022, 53 : 391 - 394