Partial least-squares calibration of two-way diode-array high-performance liquid chromatograms: influence of calibration design, noise and peak separation

被引:8
|
作者
Zissis, KD
Brereton, RG
Scott, R
机构
[1] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
[2] SmithKline Beecham Pharmaceut, Tonbridge TN11 9AN, Kent, England
关键词
high-performance liquid chromatography; partial least squares; calibration; chemometrics;
D O I
10.1039/a801285g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An approach for the calibration of two-way diode-array high-performance liquid chromatograms is described, involving unfolding a three-way data matrix and performing partial least-squares (PLS) calibration. The properties of loadings summed over time and wavelength are discussed. The influence of calibration design, noise levels and peak separation are investigated, using pseudosimulations, both by calculating prediction and test errors and by graphical representation of the summed loadings. The importance of using an independent test set is emphasized. Calibration design is shown to have a major effect both on the appearance of the loadings and on the PLS errors.
引用
收藏
页码:1165 / 1173
页数:9
相关论文
共 38 条
  • [21] Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods
    Shehata, A. B.
    Rizk, M. S.
    Rend, E. A.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2016, 24 (04) : 703 - 715
  • [22] Characterization of the Fruits and Seeds of Alpinia Oxyphylla Miq by High-Performance Liquid Chromatography (HPLC) and near-Infrared Spectroscopy (NIRS) with Partial Least-Squares (PLS) Regression
    Li, Rong
    Zeng, Canbiao
    Li, Junni
    Zhu, Kailian
    Lin, Xinxin
    Wen, Jingfeng
    Guo, Huanjia
    Weng, Wenfeng
    Wang, Dong
    Ji, Shengguo
    ANALYTICAL LETTERS, 2020, 53 (11) : 1667 - 1682
  • [23] Accurate discrimination of Gastrodia elata from different geographical origins using high-performance liquid chromatography fingerprint combined with boosting partial least-squares discriminant analysis
    Sun, Shanshan
    Li, Yancheng
    Zhu, Lijun
    Ma, Haiyan
    Li, Lupan
    Liu, Yufeng
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (17) : 2875 - 2882
  • [24] High-speed separation and characterization of major constituents in Radix Paeoniae Rubra by fast high-performance liquid chromatography coupled with diode-array detection and time-of-flight mass spectrometry
    Liu, E-Hu
    Qi, Lian-Wen
    Li, Bin
    Peng, Yong-Bo
    Li, Ping
    Li, Chang-Yin
    Cao, Jun
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (01) : 119 - 130
  • [25] Piecewise direct standardization assisted with second-order calibration methods to solve signal instability in high-performance liquid chromatography-diode array detection systems
    Chen, Yue
    Wu, Hai-Long
    Wang, Tong
    Liu, Bing-Bing
    Ding, Yu-Jie
    Yu, Ru-Qin
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1667
  • [26] Second-order calibration for simultaneous determination of pharmaceuticals in water samples by solid-phase extraction and fast high-performance liquid chromatography with diode array detector
    Akvan, Nadia
    Parastar, Hadi
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2014, 137 : 146 - 154
  • [27] PREDICTION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPACITY FACTORS FOLLOWING COLUMN CALIBRATION - INFLUENCE OF DIFFERENT SOLVENTS AND COLUMNS ON THE SEPARATION OF A SERIES OF AROMATIC AMIDES
    BATY, JD
    SHARP, S
    JOURNAL OF CHROMATOGRAPHY, 1988, 437 (01): : 13 - 31
  • [28] Rapid separation and identification of furocoumarins in Angelica dahurica by high-performance liquid chromatography with diode-array detection, time-of-flight mass spectrometry and quadrupole ion trap mass spectrometry
    Zhang, Hai
    Gong, Chungui
    Lv, Lei
    Xu, Yuanjie
    Zhao, Liang
    Zhu, Zhenyu
    Chai, Yifeng
    Zhang, Guoqing
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (14) : 2167 - 2175
  • [29] SEPARATION AND IDENTIFICATION OF TRIGLYCERIDES, CHOLESTERYL ESTERS, CHOLESTEROL, 7-DEHYDROCHOLESTEROL, DOLICHOL, UBIQUINONE, ALPHA-TOCOPHEROL, AND RETINOL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A DIODE-ARRAY DETECTOR
    GREENSPAN, MD
    LO, CYL
    HANF, DP
    YUDKOVITZ, JB
    JOURNAL OF LIPID RESEARCH, 1988, 29 (07) : 971 - 976
  • [30] RESOLVABILITY INDEXES AND VARIABLE SELECTION IN FACTOR-ANALYSIS OF DIODE-ARRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - DEVELOPMENT OF AN APPROACH FOR MULTI-PEAK CLUSTERS AND APPLICATION TO MIXTURES OF CHLOROPHYLL DEGRADATION PRODUCTS
    ELBERGALI, AK
    BRERETON, RG
    RAHMANI, A