Intra-Fraction Motion of Brain SRS/SRT with Multiple Targets: an Evaluation Based On a Robotic Radiosurgery System

被引:0
|
作者
Chen, X. [1 ]
Jin, L. [1 ]
Chen, L. [1 ]
Liu, J. [1 ]
Wang, L. [1 ]
Hayes, S. [1 ]
Weiss, S. [1 ]
Price, R. [1 ]
Ma, C. [1 ]
机构
[1] Fox Chase Canc Ctr, 7701 Burholme Ave, Philadelphia, PA 19111 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-T-
引用
收藏
页数:1
相关论文
共 50 条
  • [31] Characterization of Three-Dimensional Intra-fraction Motion Traces of Stereotactic Radiosurgery Patients with Thermoplastic Immobilization
    Lee, Young
    MacDonald, Lee
    Ruschin, Mark
    MEDICAL PHYSICS, 2019, 46 (11) : 5380 - 5380
  • [32] Management of intra-fraction organ motion: first performance evaluation of an experimental dynamic tumor tracking system
    Oelfke, U.
    Tacke, M.
    Kraus, A.
    Nill, S.
    MEDICAL PHYSICS, 2009, 36 (09) : 4302 - 4302
  • [33] Intra-fraction motion assessment of frameless intracranial radiosurgery using 1.5T MR simulator
    Yuan, J.
    Lo, G. G.
    Wong, O. L.
    Cheng, K. F.
    Fung, W. W. K.
    Zhou, Y. H.
    Chiu, G.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1064 - S1065
  • [34] Surface Imaging Based Analysis of Intra-Fraction Motion for Breast Radiotherapy Patients
    Wiant, D.
    Wentworth, S.
    Maurer, J.
    Vanderstraeten, C.
    Terrell, J.
    Sintay, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 97 - 97
  • [35] Dosimetric Analysis of Intra-Fraction Motion Detected by Surface Guided Radiation Therapy During Linac Stereotactic Radiosurgery
    Foster, R. D.
    Moeller, B. J.
    Robinson, M.
    Bright, M.
    Ruiz, J. L.
    Hampton, C. J.
    Heinzerling, J. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E540 - E540
  • [36] FRAMELESS HEAD-FIX SYSTEM EFFECTIVELY LIMITS INTRA FRACTION MOTION DURING BRAIN RADIOSURGERY
    Steenberg, R.
    Westendorp, R.
    Althof, V.
    Kattevilder, R.
    Vonk, E.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S132 - S132
  • [37] MV Portal Imaging Versus Optical Surface Imaging for Intra-Fraction Motion Detection in Intracranial Stereotactic Radiosurgery
    Sullivan, R.
    Covington, E.
    Popple, R.
    MEDICAL PHYSICS, 2018, 45 (06) : E178 - E179
  • [38] Guidelines for Normal Brain Tissue Tolerance for Multiple Brain Tumor Targets Treated with Stereotactic Radiosurgery (SRS)
    Barani, I. J.
    Sahgal, A.
    Zhang, B.
    Petti, P. L.
    Novotny, J.
    Larson, D.
    Ma, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S239 - S239
  • [39] Cone Beam CT (CBCT) Evaluation of Inter- and Intra-Fraction Motion for Patients Undergoing Brain Radiotherapy Immobilized using a Commercial Thermoplastic Mask on a Robotic Couch
    Lightstone, A. W.
    Tsao, May
    Basran, Parminder S.
    Chan, Gordon
    Pang, Geordi
    Ma, Lijun
    Lochray, Fiona
    Sahgal, Arjun
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2012, 11 (03) : 203 - 209
  • [40] Inter-Observer Variation in Intra-Fraction Motion Assessment During Intracranial Stereotactic Radiosurgery Using MV Images
    Sullivan, R.
    Wu, X.
    Covington, E.
    Popple, R.
    MEDICAL PHYSICS, 2018, 45 (06) : E178 - E178