Flexural Strength of Interim Resin Materials for Fixed Prosthodontics

被引:35
|
作者
Nejatidanesh, Farahnaz [1 ,2 ]
Momeni, Glareh [1 ]
Savabi, Omid [1 ,2 ]
机构
[1] Isfahan Univ Med Sci, Sch Dent, Dept Prosthodont, Esfahan, Iran
[2] Isfahan Univ Med Sci, Sch Dent, Torabinejad Dent Res Ctr, Esfahan, Iran
关键词
Bisphenol A-glycidyl methacrylate; methyl methacrylate; interim fixed prostheses; composite resins; interim restorative materials;
D O I
10.1111/j.1532-849X.2009.00473.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Flexural strength of interim materials is of particular concern with long-span fixed partial dentures (FPDs) or in areas of heavy contact. The purpose of this study was to compare the flexural strength of seven resins used to fabricate interim fixed prostheses. Materials and Methods: Ten identical 25 x 2 x 2 mm specimens were made from seven interim materials (N = 70) (Trim, Acropars, Protemp 3 Garant, Unifast LC, TempSpan, Tempron, Duralay) according to ADA specification #27. After 14 days' storage in artificial saliva and thermocycling for 2500 cycles (5 degrees C to 55 degrees C), a standard three-point bending test was conducted on the specimens with a universal testing machine at a crosshead speed of 0.75 mm/min. The mean values of flexural strength of each interim material were calculated. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U-test, and the significance level was set at alpha = 0.05. Results: The lowest and highest flexural strengths were found for Trim from ethyl methacrylate resins and TempSpan from bis-acryl resins, respectively. The mean rank of flexural strength of the studied materials was TempSpan = 66.3, Protemp 3 Garant = 53.4, Tempron = 47.5, Duralay = 38.3, Unifast LC = 24.1, Acropars = 17.9, and Trim = 5.9. There was no significant difference between Tempron and Protemp 3 Garant, but the other resins were significantly different. Conclusions: Bis-acryl interim materials exhibited higher flexural strength than the methacrylate resins tested in this study. These higher values should be considered in making interim fixed prostheses, especially when long-term use or long-span FPDs are planned.
引用
收藏
页码:507 / 511
页数:5
相关论文
共 50 条
  • [21] COMPARISON OF ELASTOMERIC IMPRESSION MATERIALS USED IN FIXED PROSTHODONTICS
    CIESCO, JN
    MALONE, WFP
    SANDRIK, JL
    MAZUR, B
    JOURNAL OF PROSTHETIC DENTISTRY, 1981, 45 (01): : 89 - 94
  • [22] Rotating fatigue and flexural strength of direct and indirect resin-composite restorative materials
    Mirmohammadi, Hesam
    Kleverlaan, Cornelis J.
    Feilzer, Albert J.
    AMERICAN JOURNAL OF DENTISTRY, 2009, 22 (04): : 219 - 222
  • [23] Investigations in the correlation between Martens hardness and flexural strength of composite resin restorative materials
    Fischer, Jens
    Roeske, Svenja
    Stawarczyk, Bogna
    Haemmerle, Christoph H. F.
    DENTAL MATERIALS JOURNAL, 2010, 29 (02) : 188 - 192
  • [24] Comparative Evaluation of Flexural Strength of Two Newer Composite Resin Materials: An in Vitro Study
    Patil, Akshata
    Acharya, Shashi Rashmi
    Ginjupalli, Kishore
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2021, 21
  • [25] BIAXIAL FLEXURAL STRENGTH AND HARDNESS OF RESIN-MATRIX CERAMIC CAD/CAM MATERIALS
    Alnafaiy, Sarah M.
    Labban, Nawaf
    Maawadh, Ahmed
    Al Shehri, Huda A.
    Aljamhan, Abdullah S.
    Al Ghamdi, Wejdan
    CERAMICS-SILIKATY, 2021, 65 (03) : 285 - 294
  • [26] Effect of different housing retaining materials on the flexural strength of an acrylic resin overdenture base
    Ozkir, Serhat Emre
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04): : 500 - 503
  • [27] Flexural strength of provisional materials
    Brown, J
    Xu, X
    Burgess, JO
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 180 - 180
  • [28] Effect of untreated zirconium oxide nanofiller on the flexural strength and surface hardness of autopolymerized interim fixed restoration resins
    Alhavaz, Abdolhamid
    Dastjerdi, Maryam Rezaei
    Ghasemi, Arman
    Ghasemi, Azade
    Sahraei, Abolfazl Alizadeh
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2017, 29 (04) : 264 - 269
  • [29] Flexural strength of a resin infused ceramic matrix
    Giordano, R
    Lee, S
    Pober, R
    Sabrosa, C
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 989 - 989
  • [30] FLEXURAL STRENGTH OF MICROWAVE CURED DENTURE RESIN
    SPIELBERG, J
    VAIDYANATHAN, J
    VISWANADHAN, T
    SAMANT, A
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 321 - 321