Ultrasound for evaluation of adnexal malignancy: From 2D to 3D ultrasound

被引:4
|
作者
Hata, Toshiyuki [1 ]
Hata, Kohkichi [2 ]
Noguchi, Junko [2 ]
Kanenishi, Kenji [1 ]
Shiota, Atsuko [1 ]
机构
[1] Kagawa Univ, Sch Med, Dept Perinatol & Gynecol, Miki, Kagawa 7610793, Japan
[2] Kagawa Prefectural Coll Hlth Sci, Dept Nursing, Kagawa, Japan
关键词
adnexal malignancy; color/power Doppler; histogram analysis; 2D ultrasound; 3D power Doppler; 3D ultrasound; POWER DOPPLER ULTRASOUND; ENHANCED TRANSVAGINAL SONOGRAPHY; BLOOD-FLOW CHARACTERISTICS; PREDICTING OVARIAN-CANCER; GRAY-SCALE ULTRASOUND; COLOR DOPPLER; 3-DIMENSIONAL ULTRASONOGRAPHY; PHANTOM EXPERIMENT; PELVIC MASSES; IN-VITRO;
D O I
10.1111/j.1447-0756.2011.01642.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Conventional two-dimensional (2D) ultrasound has been widely used for the evaluation of adnexal malignancy in gynecologic fields. This 2D ultrasound evaluation includes a morphological assessment, color/power and pulsed Doppler sonographic assessment, scoring system, and contrast agent assessment of adnexal masses. The introduction of three-dimensional (3D) ultrasound would facilitate the novel assessment of adnexal masses. With the recent advance in 3D power Doppler (3DPD) ultrasound as well as quantitative 3DPD histogram analysis, quantitative and qualitative assessments of the vascularization and blood flow of adnexal masses have become feasible. These novel techniques may assist in the evaluation of adnexal malignancy, and offer potential advantages relative to conventional 2D sonographic assessments. 3D ultrasound may be an important modality in future gynecologic oncology research and in the evaluation of adnexal malignancy in clinical practice, although some limitations regarding the assessment of adnexal malignancy employing 3D ultrasound remain unresolved.
引用
下载
收藏
页码:1255 / 1268
页数:14
相关论文
共 50 条
  • [1] The role of 2d ultrasound, 3d ultrasound and their doppler modes in the prediction of malignancy in women with adnexal masses
    Ziogas, A.
    Lamari, I.
    Xydias, E.
    Poulopoulou, D.
    Liasidi, P.
    Papageorgouli, D.
    Daponte, A.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 270 : E93 - E93
  • [2] 2D HISTOGRAM ULTRASOUND AND 3D ULTRASOUND CORRELATION IN RHEUMATIC DISEASES
    Mendonca, J. A.
    Provenza, J. R.
    Guissa, V. R.
    Vierhout, C. V.
    Pedri, L. E.
    Frazon, P. G. U.
    Lyrio, A. M.
    Peron Filho, F.
    Bonfiglioli, R.
    Schincariol, N. B.
    ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 : 1253 - 1254
  • [3] 3D Kidney Reconstruction from 2D Ultrasound Images
    Teresa Alvarez-Gutierrez, Mariana
    Rodrigo Mejia-Rodriguez, Aldo
    Alejandro Cruz-Guerrero, Ines
    Roman Arce-Santana, Edgar
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 393 - 400
  • [4] 3D segmentation of kidney tumors from freehand 2D ultrasound
    Ahmad, Anis
    Cool, Derek
    Chew, Ben H.
    Pautler, Stephen E.
    Peters, Terry M.
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [5] Hemimegalencephaly: 2D, 3D Ultrasound and MRI Correlation
    Romero, X. C.
    Molina, F. S.
    Pastor, E.
    Amaya, F.
    FETAL DIAGNOSIS AND THERAPY, 2011, 29 (03) : 257 - 260
  • [6] 2D and 3D Ultrasound Examination of Labia Minora
    Battaglia, Cesare
    Battaglia, Bruno
    Busacchi, Paolo
    Paradisi, Roberto
    Meriggiola, Maria Cristina
    Venturoli, Stefano
    ARCHIVES OF SEXUAL BEHAVIOR, 2013, 42 (01) : 153 - 160
  • [7] 2D and 3D Ultrasound Examination of Labia Minora
    Cesare Battaglia
    Bruno Battaglia
    Paolo Busacchi
    Roberto Paradisi
    Maria Cristina Meriggiola
    Stefano Venturoli
    Archives of Sexual Behavior, 2013, 42 : 153 - 160
  • [8] COMPRESSED 3D ULTRASOUND IMAGING WITH 2D ARRAYS
    Birk, Michael
    Burshtein, Amir
    Chernyakova, Tanya
    Eilam, Alon
    Choe, Jung Woo
    Nikoozadeh, Amin
    Khuri-Yakub, Pierre
    Eldar, Yonina C.
    2014 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2014,
  • [9] Evaluation of 2D and 3D ultrasound tracking algorithms and impact on ultrasound-guided liver radiotherapy margins
    De Luca, Valeria
    Banerjee, Jyotirmoy
    Hallack, Andre
    Kondo, Satoshi
    Makhinya, Maxim
    Nouri, Daniel
    Royer, Lucas
    Cifor, Amalia
    Dardenne, Guillaume
    Goksel, Orcun
    Gooding, Mark J.
    Klink, Camiel
    Krupa, Alexandre
    Le Bras, Anthony
    Marchal, Maud
    Moelker, Adriaan
    Niessen, Wiro J.
    Papiez, Bartlomiej W.
    Rothberg, Alex
    Schnabel, Julia
    van Walsum, Theo
    Harris, Emma
    Bell, Muyinatu A. Lediju
    Tanner, Christine
    MEDICAL PHYSICS, 2018, 45 (11) : 4986 - 5003
  • [10] The role of 2D ultrasound, 3D ultrasound and 3D doppler in the diagnosis of endometrial cancer in women with uterine bleeding
    Ziogas, A.
    Kalantzi, S.
    Xydias, E.
    Beis, N.
    Gkoulovagka, D.
    Grapsidi, V.
    Daponte, A.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 270 : E91 - E91