Cell-SELEX Based Identification of an RNA Aptamer for Escherichia coli and Its Use in Various Detection Formats

被引:26
|
作者
Dua, Pooja [1 ]
Ren, Shuo [2 ]
Lee, Sang Wook [2 ]
Kim, Joon-Ki [1 ]
Shin, Hye-su [1 ]
Jeong, Ok-Chan [3 ,4 ]
Kim, Soyoun [2 ]
Lee, Dong-Ki [1 ]
机构
[1] Sungkyunkwan Univ SKKU, Dept Chem, Global Res Lab GRL RNAi Med, Suwon 16419, South Korea
[2] Dongguk Univ, Dept Bioengn, Seoul 04620, South Korea
[3] Inje Univ, Dept Biomed Engn, Gimhae 50834, South Korea
[4] Inje Univ, Sch Mech Engn, Gimhae 50834, South Korea
基金
新加坡国家研究基金会;
关键词
aptamer; biolayer Interferometry; biosensor; cell-SELEX; Escherichia coli; impedimetric sensor; LABEL-FREE DETECTION; SENSITIVE DETECTION; BIOLAYER INTERFEROMETRY; PATHOGEN DETECTION; DNA APTAMERS; BIOSENSOR; SAFETY; GENOSENSOR; SELECTION; O157-H7;
D O I
10.14348/molcells.2016.0167
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Escherichia coli are important indicator organisms, used routinely for the monitoring of water and food safety. For quick, sensitive and real-time detection of E. coli we developed a 2'F modified RNA aptamer Ec3, by Cell-SELEX. The 31 nucleotide truncated Ec3 demonstrated improved binding and low nano-molar affinity to E. coli. The aptamer developed by us out-performs the commercial antibody and aptamer used for E. coli detection. Ec3(31) aptamer based E. coli detection was done using three different detection formats and the assay sensitivities were determined. Conventional Ec3(31)-biotin-streptavidin magnetic separation could detect E. coli with a limit of detection of 1.3 x 10(6) CFU/ml. Although, optical analytic technique, biolayer interferometry, did not improve the sensitivity of detection for whole cells, a very significant improvement in the detection was seen with the E. coli cell lysate (5 x 10(4) CFU/ml). Finally we developed Electrochemical Impedance Spectroscopy (EIS) gap capacitance biosensor that has detection limits of 2 x 10(4) CFU/mL of E. coli cells, without any labeling and signal amplification techniques. We believe that our developed method can step towards more complex and real sample application.
引用
收藏
页码:807 / 813
页数:7
相关论文
共 50 条
  • [41] A Visual and Sensitive Detection of Escherichia coli Based on Aptamer and Peroxidase-like Mimics of Copper-Metal Organic Framework Nanoparticles
    Nuo Duan
    Wei Yang
    Shijia Wu
    Ying Zou
    Zhouping Wang
    Food Analytical Methods, 2020, 13 : 1433 - 1441
  • [42] A Visual and Sensitive Detection of Escherichia coli Based on Aptamer and Peroxidase-like Mimics of Copper-Metal Organic Framework Nanoparticles
    Duan, Nuo
    Yang, Wei
    Wu, Shijia
    Zou, Ying
    Wang, Zhouping
    FOOD ANALYTICAL METHODS, 2020, 13 (07) : 1433 - 1441
  • [43] MONITORING CELL POTENTIAL OF ESCHERICHIA-COLI WITH USE OF AN ELECTRODE SENSITIVE TO TETRAPHENYL PHOSPHONIUM - CHANGE BY ADDITION OF VARIOUS SUGARS
    MURATSUGU, M
    KAMO, N
    KOBATAKE, Y
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1982, 9 (03): : 325 - 331
  • [44] Mass Spectrometry Proteotyping-Based Detection and Identification of Staphylococcus aureus, Escherichia coli, and Candida albicans in Blood
    Kondori, Nahid
    Kurtovic, Amra
    Pineiro-Iglesias, Beatriz
    Salva-Serra, Francisco
    Jaen-Luchoro, Daniel
    Andersson, Bjorn
    Alves, Gelio
    Ogurtsov, Aleksey
    Thorsell, Annika
    Fuchs, Johannes
    Tunovic, Timur
    Kamenska, Nina
    Karlsson, Anders
    Yu, Yi-Kuo
    Moore, Edward R. B.
    Karlsson, Roger
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2021, 11
  • [45] IDENTIFICATION OF ENTEROPATHOGENIC ESCHERICHIA-COLI BY PCR-BASED DETECTION OF THE BUNDLE-FORMING PILUS GENE
    GUNZBURG, ST
    TORNIEPORTH, NG
    RILEY, LW
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (05) : 1375 - 1377
  • [46] Validation of a Cell-Based Assay for Detection of Active Shiga Toxins Produced by Escherichia coli in Water
    Hughes, Anna C.
    Patfield, Stephanie
    Rasooly, Reuven
    He, Xiaohua
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (21) : 1 - 9
  • [47] IMMUNOENZYME COMPLEX BASED ON A POLYFUNCTIONAL CARRIER AND ITS USE FOR IDENTIFICATION AND DETECTION OF MICROORGANISMS
    NARKEVICH, AN
    DERVOED, VV
    KOZLOVA, VA
    KOCHETKOVA, AP
    BEZUGLOVA, EV
    LABORATORNOE DELO, 1982, (12): : 748 - 749
  • [48] EFFECTS OF VARIOUS TRIAMINES ON CELL-FREE POLYPEPTIDE-SYNTHESIS OF ESCHERICHIA-COLI AND ON GROWTH OF ITS POLYAMINE AUXOTROPHS
    KOUMOTO, Y
    HISAMOTO, Y
    SHINODA, S
    YAMAMOTO, S
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1990, 38 (06) : 1648 - 1652
  • [49] USE OF ERYTHROCYTES OF VARIOUS ORIGINS IN SEROLOGICAL TESTS FOR DETECTION OF THERMOLABILE ESCHERICHIA-COLI ENTERO-TOXIN FROM MAN AND SWINE
    RICCI, LC
    SERAFIM, MB
    DESIQUEIRA, PS
    DECASTRO, AFP
    REVISTA DE MICROBIOLOGIA, 1988, 19 (03): : 217 - 222
  • [50] A sensitive lateral flow biosensor for Escherichia coli O157:H7 detection based on aptamer mediated strand displacement amplification
    Wu, Wei
    Zhao, Shiming
    Mao, Yiping
    Fang, Zhiyuan
    Lu, Xuewen
    Zeng, Lingwen
    ANALYTICA CHIMICA ACTA, 2015, 861 : 62 - 68