Quantitative attenuation correction for PET/CT using iterative reconstruction of low-dose dual-energy CT

被引:0
|
作者
Kinahan, PE [1 ]
Fessler, JA [1 ]
Alessio, AM [1 ]
Lewellen, TK [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present the results of using iterative reconstruction of dual-energy CT (DECT) to perform accurate CT-based attenuation correction (CTAC) for PET emission images. Current methods, such as bilinear scaling, introduce quantitative errors in the PET enitission image for bone, metallic implants, and contrast agents. DECT has had limited use in the past for quantitative CT imaging due to increased patient dose and high noise levels in the decoupled CT basis-material images. Reconstruction methods that model the acquisition physics impose a significant computational burden due to the large image matrix size (typically 512 x 512). For CTAC, however, three factors make DECT feasible: (1) a smaller matrix is needed for the transmission image, which reduces the noise per pixel, (2) a smaller matrix significantly accelerates an iterative CT reconstruction algorithm, (3) the monoenergetic transmission image at 511 keV is the sum of the two decoupled basis-material images. Initial results using a 128 x 128 matrix size for a test object comprised of air, soft tissue, dense bone, and a mixture of tissue and bone demonstrate a significant reduction of bias using DECT (from 20% to similar to 0% for the tissue/bone mixture). FBP reconstructed images, however, have significant noise. Noise levels are reduced from similar to 8% to similar to 3% by the use of PWLS reconstruction.
引用
收藏
页码:3285 / 3289
页数:5
相关论文
共 50 条
  • [41] Iterative reconstruction of low-dose CT based on differential sparse
    Lu, Siyu
    Yang, Bo
    Xiao, Ye
    Liu, Shan
    Liu, Mingzhe
    Yin, Lirong
    Zheng, Wenfeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [42] Low-dose CT coronary angiography using iterative reconstruction with a 256-slice CT scanner
    Carrascosa, Patricia
    Rodriguez-Granillo, Gaston A.
    Capunay, Carlos
    Deviggiano, Alejandro
    WORLD JOURNAL OF CARDIOLOGY, 2013, 5 (10): : 382 - 386
  • [43] Optimization of low dose CT based attenuation correction for brain PET/CT protocols
    Kim, Jung Sun
    Kim, Ho Sung
    Ryu, Jae Kwang
    Jung, Woo Young
    Dong, Kyeong Rae
    Chung, Woon Kwan
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [44] Optimization of low dose CT based attenuation correction for brain PET/CT protocols
    Kim, Jung Sun
    Kim, Ho Sung
    Ryu, Jae Kwang
    Jung, Woo Young
    Dong, Kyeong Rae
    Chung, Woon Kwan
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [45] Quantitative accuracy of 18FDG uptake in metastatic liver lesions with PET CT:: Iterative Reconstruction with CT attenuation correction versus iterative reconstruction and FBP with 68Ge attenuation correction.
    Patel, P
    Chin, BB
    Osman, M
    Marshall, L
    Wahl, RL
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 214P - 214P
  • [46] Survey of CT dose for PET/CT localization and attenuation correction
    Jallow, Ngoneh
    Nye, Jonathon
    Christian, Paul
    Sunderland, John
    Graham, Michael
    Hoffman, John
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [47] Low-dose dual-energy electronic cleansing for fecal-tagging CT colonography
    Cai, Wenli
    Zhang, Da
    Lee, June-Goo
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [48] Dual-Energy CT and Radiation Dose
    Reher, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (01) : 95 - 96
  • [49] Iterative algorithms for low-dose CT
    Li, X
    Madsen, MT
    Jiang, M
    Wang, G
    RADIOLOGY, 2002, 225 : 255 - 255
  • [50] Effect of the dose reduction applied low dose for PET/CT according to CT attenuation correction method
    Jeong, Seung Woo
    Kim, Hong Gyun
    Gwon, Jae Beom
    Shin, Young Man
    Kim, Yeong Heon
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55