摘要
We present the results of using iterative reconstruction of dual-energy CT (DECT) to perform accurate CT-based attenuation correction (CTAC) for PET emission images. Current methods, such as bilinear scaling, introduce quantitative errors in the PET enitission image for bone, metallic implants, and contrast agents. DECT has had limited use in the past for quantitative CT imaging due to increased patient dose and high noise levels in the decoupled CT basis-material images. Reconstruction methods that model the acquisition physics impose a significant computational burden due to the large image matrix size (typically 512 x 512). For CTAC, however, three factors make DECT feasible: (1) a smaller matrix is needed for the transmission image, which reduces the noise per pixel, (2) a smaller matrix significantly accelerates an iterative CT reconstruction algorithm, (3) the monoenergetic transmission image at 511 keV is the sum of the two decoupled basis-material images. Initial results using a 128 x 128 matrix size for a test object comprised of air, soft tissue, dense bone, and a mixture of tissue and bone demonstrate a significant reduction of bias using DECT (from 20% to similar to 0% for the tissue/bone mixture). FBP reconstructed images, however, have significant noise. Noise levels are reduced from similar to 8% to similar to 3% by the use of PWLS reconstruction.
引用
收藏
页码:3285 / 3289
页数:5
相关论文
共 50 条
  • [1] Dictionary Learning Based Quantitative Reconstruction for Low-Dose Dual-Energy CT (DECT)
    Xu, Q.
    Xing, L.
    Xiong, G.
    Elmore, K.
    Min, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3250 - 3251
  • [2] Usefulness of CT iterative reconstruction method for low-dose CT attenuation correction on the accuracy of PET image in obesity phantom study
    Matsutomo, Norikazu
    Onishi, Hideo
    Nagaki, Akio
    Matsumoto, Keiichi
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [3] Stones: Low-dose dual-energy CT
    Payton S.
    Nature Reviews Urology, 2011, 8 (1) : 7 - 7
  • [4] Attenuation correction in PET/CT from ultra-low dose CT: Photon starvation and iterative CT reconstruction
    Palmer, Matthew
    Fahey, Frederic
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [5] Iterative Reconstruction for Quantitative Tissue Decomposition in Dual-Energy CT
    Magnusson, Maria
    Malusek, Alexandr
    Muhammad, Arif
    Carlsson, Gudrun Alm
    IMAGE ANALYSIS: 17TH SCANDINAVIAN CONFERENCE, SCIA 2011, 2011, 6688 : 479 - 488
  • [6] Attenuation correction of PET cardiac data with low-dose average CT in PET/CT
    Pan, Tinsu
    Mawlawi, Osama
    Luo, Dershan
    Liu, Hui H.
    Chi, Pai-Chun M.
    Mar, Martha V.
    Gladish, Gregory
    Truong, Mylene
    Erasmus, Jeremy, Jr.
    Liao, Zhongxing
    Macapinlac, H. A.
    MEDICAL PHYSICS, 2006, 33 (10) : 3931 - 3938
  • [7] The optimal protocols of low-dose CT with iterative reconstruction CT in PET/CT scan
    Yang, Bang-Hung
    Wu, Nien-Yun
    Chen, Guan-Ling
    Wu, Tung-Hsin
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [8] Low-dose interpolated average CT for attenuation correction in cardiac PET/CT
    Wu, Tung-Hsin
    Zhang, Geoffrey
    Wang, Shyh-Jen
    Chen, Chih-Hao
    Yang, Bang-Hung
    Wu, Nien-Yun
    Huang, Tzung-Chi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 361 - 364
  • [9] Ultra low-dose CT attenuation correction in PET SPM
    Wang, Shyh-Jen
    Yang, Bang-Hung
    Tsai, Chia-Jung
    Yang, Ching-Ching
    Lee, Jason J. S.
    Wu, Tung-Hsin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 397 - 400
  • [10] Dual energy CT for attenuation correction with PET/CT
    Xia, Ting
    Alessio, Adam M.
    Kinahan, Paul E.
    MEDICAL PHYSICS, 2014, 41 (01)