Biomechanical comparison of four different fixation methods in the management of Pauwels type III femoral neck fractures: Is there a clear winner?

被引:8
|
作者
Yildirim, Cem [1 ]
Demirel, Mehmet [2 ]
Karahan, Goekhan [1 ]
Cetinkaya, Engin [3 ]
Misir, Abduelhamit [4 ]
Yamak, Fatih [5 ]
Bozdag, Erguen [5 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Sch Med, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Bahcesehir Univ, Medicalpark Goztepe Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[4] Medicana Int Istanbul Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Istanbul Tech Univ, Fac Mech Engn Strength Mat & Biomech, Istanbul, Turkey
关键词
Pauwels type III femoral neck fractures; Cannulated screws; Medial buttress plate; Inverted triangle configuration; Distal unicortical; Distal bicortical screw placement; MEDIAL BUTTRESS PLATE; CANNULATED SCREW; INTRACAPSULAR FRACTURES; HIP SCREW;
D O I
10.1016/j.injury.2022.06.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Cannulated screws augmented with the medial buttress plate could confer greater biomechanical stability and higher union rates than the screw fixation alone for treating young patients with Pauwels type III femoral neck fractures (FNFs). No study has evaluated the effects of distal bicortical screw fixation and biomechanical properties of buttress plate augmentation under simultaneous vertical and rotational forces, physiologically acting on the hip joint. This study aimed to compare the biomechanical properties of four methods of three cannulated screw fixation under the combined axial and torsional loading in a synthetic femur model of type III FNF.Methods: Twenty-four third-generation composite femora were divided into four groups (6 femora in each group) based on the screw fixation configuration: inverted triangle configuration ( Group A ), Pauwels' configuration ( Group B ), inverted triangle configuration combined with medial buttress plate using distal unicortical ( Group C ), and distal bicortical screw placement ( Group D ). A Pauwels type III FNF was simulated on the sawbones. Each model was subjected to the combined axial and torsional cyclic loading and subsequently tested to failure.Result: Significant differences were determined in axial stiffness (AS) among the four groups ( p = 0.024), whereas there was no significant difference in torsional stiffness ( p = 0.147). The mean AS was higher in group D (639.5 +/- 86.2 N/mm) than in group A (430.6 +/- 94.8 N/mm), group B (426.2 +/- 41.9 N/mm), and group C (451.2 +/- 156.7 N/mm). Failure forces (FFs) were significantly different among four groups ( p = 0.007), while there was no considerable difference in failure moment values ( p = 0.555). The mean FF was significantly higher in group D (1307.1 +/- 96.4 N) than in group A (1076.9 +/- 371.2 N) and group B (1075.5 +/- 348.3 N) ( p = 0.014 and p = 0.018, respectively). There was no significant difference in the mean FF between groups D and C.Conclusion: Regardless of the medial plate use, multiple cannulated systems could provide similar biomechanical results regarding torsional stiffness and failure moments. Bicortical placement of the most distal screw in medial buttress plate application could improve axial stability but not significantly affect the rotational stability of the inverted triangle screw fixation system in managing type III FNFs.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3124 / 3129
页数:6
相关论文
共 50 条
  • [41] Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation
    Maekinen, Tatu J.
    Dhotar, Herman S.
    Fichman, Simcha G.
    Gunton, Matthew J.
    Woodside, Mitchell
    Safir, Oleg
    Backstein, David
    Willett, Thomas L.
    Kuzyk, Paul R. T.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1737 - 1742
  • [42] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Zhichao Gao
    Mei Wang
    Baojie Shen
    Xiaodong Chu
    Di Ruan
    Scientific Reports, 11
  • [43] Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
    Onder, Yilmaz
    Bulut, Tugrul
    Eroglu, Osman Nuri
    Ciklacandir, Samet
    Isler, Yalcin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (06)
  • [44] Finite element analysis of a new plate for Pauwels type III femoral neck fractures
    Wang, Gang
    Tang, Yong
    Wu, Xuhua
    Yang, Huilin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (02)
  • [45] Biomechanical and clinical evaluation of interlocking hip screw in Pauwels III femoral neck fractures: A comparison with inverted triangle cannulated screws
    Zhang, Jian
    Jiang, Haozheng
    Dai, Wei
    Hersi, Salad Abdirahman
    Cheong, John Chun Tien Chui Wan
    Chu, Zhenchen
    Lou, Zhiyuan
    Zhang, Deqiang
    Liu, Changjian
    Tian, Kang
    Tang, Xin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [46] Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS)
    Chong Nan
    Liang Ma
    Yuechuang Liang
    Yanjun Li
    Zhanbei Ma
    BMC Musculoskeletal Disorders, 23
  • [47] Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS)
    Nan, Chong
    Ma, Liang
    Liang, Yuechuang
    Li, Yanjun
    Ma, Zhanbei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [48] Results of Internal Fixation of Pauwels Type-3 Vertical Femoral Neck Fractures Reply
    Haidukewych, George J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (02): : 491 - 491
  • [49] Torsional stability of fixation methods in basicervical femoral neck fractures: a biomechanical study
    Mahaisavariya, Chantas
    Jitprapaikulsarn, Surasak
    Mahaisavariya, Banchong
    Chantarapanich, Nattapon
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [50] Biomechanical comparison using finite element analysis of different screw configurations in the fixation of femoral neck fractures
    Gok, K.
    Inal, S.
    MECHANICAL SCIENCES, 2015, 6 (02) : 173 - 179