Using Rogowski Coils Inside Protective Relays

被引:0
|
作者
Skendzic, Veselin [1 ]
Hughes, Bob [2 ]
机构
[1] Schweitzer Engn Labs Inc, Pullman, WA 99163 USA
[2] Schweitzer Engn Labs Inc, Protect Syst Dept, Pullman, WA 99163 USA
来源
2013 66TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS | 2013年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditionally, microprocessor-based relays incorporate a secondary current transformer to convert the 5 A or 1 A input current to a lower level for input to an analog-to-digital (A/D) converter as part of the input processing. The limits of this input circuit are well known, and relay designers take them into account when determining operating characteristics. A Rogowski coil produces an output based on the rate of change of the current input, so passing the output of the coil through an integrator produces a signal that is proportional to the current. There are additional characteristics of a Rogowski coil that give it particular advantages for use in a microprocessor-based relay, including the following: An air core. This leads to no saturation, even at very high currents. A flexible shape. With no iron core, the coil can be shaped and sized to fit the application. Immunity to electromagnetic interference. This makes the coil suitable for electrically noisy environments. These advantages, and others, make a Rogowski coil something to consider for the input of microprocessor-based relays, where the integration required to obtain the input current is a relatively easy operation. This paper discusses the practical considerations of using this coil in a relay. Complicating and mitigating factors are discussed, along with the performance impact on the relay and practical experiences in the field. Application impacts of Rogowski coil use are presented, including which types of relays are most benefited by this technology. Future implications of this technology are also presented.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] Improvement of characteristics of zero-phase-sequence current detector by using rogowski coils
    Iwasaki Electric Installation safety Management Office, 2-14-2. Fuse-Shinmachi, Kashiwa 277-0823
    不详
    不详
    不详
    IEEJ Trans. Power Energy, 2006, 11 (1112-1120):
  • [42] MEASUREMENT OF LIGHTNING CURRENTS USING A COMBINATION OF ROGOWSKI COILS AND B-DOT SENSORS
    Romero, C.
    Mediano, A.
    Rubinstein, A.
    Rachidi, F.
    Rubinstein, M.
    Paolone, M.
    Zweiacker, P.
    Mora, N.
    Pavanello, D.
    Daout, B.
    2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [43] PROTECTIVE RELAYS - FOREWORD
    HAHN, C
    BROWN BOVERI REVIEW, 1978, 65 (06): : 344 - 344
  • [44] Maintenance of Protective Relays
    Kokorin, Evgenii L.
    Dmitriev, Stepan A.
    2017 IEEE 58TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2017,
  • [45] FEM ANALYSIS OF ROGOWSKI COILS COUPLED WITH BAR CONDUCTORS
    Marracci, Mirko
    Tellini, Bernardo
    Zappacosta, Carmine
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 887 - 891
  • [46] A Method for Increasing the Bandwidth of Rogowski Coils Without Changing Their Size
    Liu, Xiaoyu
    He, Yigang
    Huang, Hui
    Xu, Qing
    Huang, Tao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [47] Research on a Novel Current Transducer Based on Discrete Rogowski Coils
    Sun, Chao
    Yan, Jing
    Geng, Yingsan
    Zhang, Kun
    Xu, Mengyuan
    Liu, Jianfeng
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 798 - 801
  • [48] Ion beam measurement using Rogowski coils in a hundred of joules dense plasma focus device
    Jain, J.
    Moreno, J.
    Pavez, C.
    Bora, B.
    Inestrosa-Izurieta, M. J.
    Avaria, G.
    Soto, L.
    XIX CHILEAN PHYSICS SYMPOSIUM 2014, 2016, 720
  • [49] External Magnetic Fields Effect on Harmonics Measurements with Rogowski coils
    Mingotti, Alessandro
    Costa, Federica
    Peretto, Lorenzo
    Tinarelli, Roberto
    2021 IEEE 11TH INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2021,
  • [50] Effects on the Accuracy Performance of Rogowski Coils Due to Temperature and Humidity
    Mingotti, Alessandro
    Costa, Federica
    Peretto, Lorenzo
    Tinarelli, Roberto
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,