Biomechanical effects of metastasis in the osteoporotic lumbar spine: A Finite Element Analysis

被引:31
|
作者
Salvatore, Giuseppe [1 ]
Berton, Alessandra [1 ]
Giambini, Hugo [2 ]
Ciuffreda, Mauro [1 ]
Florio, Pino [1 ]
Longo, Umile Giuseppe [1 ]
Denaro, Vincenzo [1 ]
Thoreson, Andrew [2 ]
An, Kai-Nan [2 ]
机构
[1] Campus Biomed Univ, Dept Orthopaed & Trauma Surg, Via Alvaro del Portillo 200, I-00128 Rome, Italy
[2] Mayo Clin, Div Orthopaed Res, Biomech Lab, Rochester, MN USA
来源
关键词
Metastasis; Vertebral fracture; Vertebroplasty; Osteoporosis; Finite element analysis; Lumbar spine; BURST FRACTURE RISK; METASTATICALLY INVOLVED SPINE; VERTEBRAL FRACTURES; TRABECULAR BONE; MINERAL-CONTENT; BREAST-CANCER; CONSERVATIVE MANAGEMENT; THORACIC VERTEBRAE; CT SCANS; PREDICTION;
D O I
10.1186/s12891-018-1953-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cancer patients are likely to undergo osteoporosis as consequence of hormone manipulation and/or chemotherapy. Little is known about possible increased risk of fracture in this population. The aim of this study was to describe the biomechanical effect of a metastatic lesion in an osteoporotic lumbar spine model. Methods: A finite element model of two spinal motion segments (L3-L5) was extracted from a previously developed L3-Sacrum model and used to analyze the effect of metastasis size and bone mineral density (BMD) on Vertebral bulge (VB) and Vertebral height (VH). VB and VH represent respectively radial and axial displacement and they have been correlated to burst fracture. A total of 6 scenarios were evaluated combining three metastasis sizes (no metastasis, 15% and 30% of the vertebral body) and two BMD conditions (normal BMD and osteoporosis). Results: 15% metastasis increased VB and VH by 178% and 248%, respectively in normal BMD model; while VB and VH increased by 134% and 174% in osteoporotic model. 30% metastasis increased VB and VH by 88% and 109%, respectively, when compared to 15% metastasis in normal BMD model; while VB and VH increased by 59% and 74% in osteoporotic model. Conclusion: A metastasis in the osteoporotic lumbar spine always leads to a higher risk of vertebral fracture. This risk increases with the size of the metastasis. Unexpectedly, an increment in metastasis size in the normal BMD spine produces a greater impact on vertebral stability compared to the osteoporotic spine.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Biomechanical effects of metastasis in the osteoporotic lumbar spine: A Finite Element Analysis
    Giuseppe Salvatore
    Alessandra Berton
    Hugo Giambini
    Mauro Ciuffreda
    Pino Florio
    Umile Giuseppe Longo
    Vincenzo Denaro
    Andrew Thoreson
    Kai-Nan An
    [J]. BMC Musculoskeletal Disorders, 19
  • [2] Biomechanical Analysis of Lumbar Interbody Fusion Cages With Various Elastic Moduli in Osteoporotic and Non-osteoporotic Lumbar Spine: A Finite Element Analysis
    Zou, Da
    Yue, Lihao
    Fan, Zheyu
    Zhao, Yi
    Leng, Huijie
    Sun, Zhuoran
    Li, Weishi
    [J]. GLOBAL SPINE JOURNAL, 2024, 14 (07) : 2053 - 2061
  • [3] Biomechanical effects of the Coflex™ implantation on the lumbar spine A nonlinear finite element analysis
    Pan, Hong
    Chen, Bo
    Deng, Lian-Fu
    [J]. SAUDI MEDICAL JOURNAL, 2010, 31 (10) : 1130 - 1136
  • [4] Biomechanical effects of laminectomies in the human lumbar spine: a finite element study
    Spina, Nicholas T.
    Moreno, Genesis S.
    Brodke, Darrel S.
    Finley, Sean M.
    Ellis, Benjamin J.
    [J]. SPINE JOURNAL, 2021, 21 (01): : 150 - 159
  • [5] Nonlinear finite-element analysis and biomechanical evaluation of the lumbar spine
    Wong, C
    Gehrchen, PM
    Darvann, T
    Kiær, T
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (06) : 742 - 746
  • [6] Biomechanical Effects of Thoracic Flexibility and Stiffness on Lumbar Spine Loading: A Finite Element Analysis Study
    Morimoto, Masatoshi
    Tripathi, Sudharshan
    Kodigudla, Manoj
    Motohashi, Emi
    Fujitani, Junzo
    Goel, Vijay K.
    Sairyo, Koichi
    [J]. WORLD NEUROSURGERY, 2024, 184 : E282 - E290
  • [7] Comparison of the biomechanical effects of lumbar disc degeneration on normal patients and osteoporotic patients: A finite element analysis
    Zhang, Xin-Ying
    Han, Ye
    [J]. MEDICAL ENGINEERING & PHYSICS, 2023, 112
  • [8] Lumbar spine implant design with finite element method and determination of biomechanical effects
    Taherzadeh, Paniz
    Kelleci, Kübra
    Özer, Sevil
    [J]. Journal of the Faculty of Engineering and Architecture of Gazi University, 2023, 38 (03): : 1945 - 1952
  • [9] Lumbar spine implant design with finite element method and determination of biomechanical effects
    Taherzadeh, Paniz
    Kelleci, Kubra
    Ozer, Sevil
    [J]. JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2023, 38 (03): : 1945 - 1952
  • [10] Biomechanical Effects of Multi-segment Fixation on Lumbar Spine and Sacroiliac Joints: A Finite Element Analysis
    Zhao, Geng
    Wang, Lianlei
    Wang, Hongwei
    Li, Chao
    Yuan, Suomao
    Sun, Junyuan
    Tian, Yonghao
    Liu, Xinyu
    [J]. ORTHOPAEDIC SURGERY, 2024,