Simulation of absorbed dose, in molecular therapy, by means of Monte Carlo method using free software GEANT4: GATE

被引:0
|
作者
Echevarria Torres, Waldo Jose [1 ]
Manso Nobrega, Weiner [2 ]
Gonzalez Gonzalez, Joaquin [3 ]
Fragoso Negrin, Jose Alejandro [4 ]
机构
[1] Univ Cent Las Villas, Santa Clara, Villa Clara, Cuba
[2] Inst Tecnol Aguascalientes, Aguascalientes, Aguascalientes, Mexico
[3] Inst Nacl Oncol & Radiobiol, Havana, La Habana, Cuba
[4] Inst Super Tecnol & Ciencias Aplicadas, Havana, La Habana, Cuba
来源
关键词
radiotherapy; radiation dosage; absorption; radiation; simulation technique; Monte Carlo Method;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: there is still no optimal way to determine the dose absorbed by tumors; this lack of knowledge is the reason why the final dose of treatment is unpredictable. For this reason, patients may be receiving doses greater than the minimum required for their correct diagnosis. Objective: to create a source code for an application project of the GATE program in the simulation of absorbed dose in molecular radiotherapy, by Monte Carlo method, for a Giap phantom. Methods: the simulation was carried out by the Montecarlo method from modeling the Giap phantom, using the GATE simulation platform. The results obtained were compared with the information reflected in the bibliography on standardized best practices. Results: a source code implemented in GATE was prepared for the determination of the absorbed dose in molecular radiotherapy. Non-uniform distribution of doses was obtained in a medium with uniform activity and an approximate 2% uncertainty (in correspondence with the values reported in the literature), the results allow to affirm that the dose simulation through the GATE platform is reliable, of little computational expense and highly recommended. Conclusions: it is advisable to use the GATE platform for the simulation of the calculation of the absorbed dose because it is fast, of low computational cost and reliable.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [41] VERIFICATION OF A PROTON THERAPY FACILITY MONTE CARLO SIMULATION BASED ON THE GAMOS/GEANT4 FRAMEWORK
    Lagares, J. I.
    Arce, P.
    Terron, J. A.
    Nieto-Camero, J. J.
    Sansaloni, F.
    Korf, A.
    Romero Exposito, M. T.
    Nunez, L.
    Rodriguez, R.
    Loubser, M.
    Sanchez-Doblado, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S531 - S531
  • [42] Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle
    Shin, Jae-ik
    Yoo, SeungHoon
    Cho, Sungho
    Kim, Eun Ho
    Song, Yongkeun
    Jung, Won-Gyun
    MEDICAL PHYSICS, 2016, 43 (06) : 3496 - 3496
  • [43] Geant4 portlet: Monte-Carlo simulation with Geant4 on bwGRiD over a browser-based interface
    Zyl, A.
    Hesser, J.
    Mosch, C.
    Alnewaini, Z.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 168 - 169
  • [44] Geant4 based Monte Carlo simulation for verifying the modified sum-peak method
    Aso, Tsukasa
    Ogata, Yoshimune
    Makino, Ryuta
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 147 - 150
  • [45] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398
  • [46] Development of a Full Monte Carlo Therapeutic Dose Calculation Toolkit for Halcyon Using Geant4
    Liu, R.
    Ji, Z.
    Cai, B.
    Hugo, G.
    Mutic, S.
    Zhao, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E742 - E742
  • [47] Study of Dose Enhancement Effects in the Vicinity of High Z Atoms with Geant4 Monte Carlo Simulation
    Huang, Ke
    Yan, Kaiguo
    Yu, Yan
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1260 - 1264
  • [48] Systematic Analysis of the Neutron Equivalent Dose in a Mevion S250 Proton Therapy Machine Using Geant4 Monte Carlo Simulation
    Tatari, N.
    Baradaran-Ghahfarokhi, M.
    Roeder, B.
    Zhao, T.
    Khan, R.
    Sobotka, L.
    Darafsheh, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [49] Monte Carlo simulation of Novalis Classic 6 MV accelerator using phase space generation in GATE/Geant4 code
    Teixeira, M. S.
    Batista, D. V. S.
    Braz, D.
    da Rosa, L. A. R.
    PROGRESS IN NUCLEAR ENERGY, 2019, 110 : 142 - 147
  • [50] G4DARI: Geant4/GATE based Monte Carlo simulation interface for dosimetry calculation in radiotherapy
    Slimani, Faical A. A.
    Hamdi, Mahdjoub
    Bentourkia, M'hamed
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2018, 67 : 30 - 39