Continued testing of the cannon caliber electromagnetic gun system (CCEMG)

被引:13
|
作者
Werst, MD [1 ]
Penney, CE [1 ]
Hotz, TJ [1 ]
Kitzmiller, JR [1 ]
机构
[1] Univ Texas, Ctr Electromech, Austin, TX 78758 USA
关键词
D O I
10.1109/20.738437
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The cannon caliber electromagnetic gun system is based upon a compulsator driven 30 mm rapid fire railgun system. The objective of the program was to develop a compact, lightweight test bed capable of launching three, five round salvos of 185 g integrated launch packages to 1.85 km/s at a firing rate of 5 Hz. Per contractual requirements, the pulse power system is also size compatible with the Amphibious Assault Vehicle. The pulse power system was developed around a fourth generation air-core, ii-pole rotating armature, self-excited, compulsator design. Although the contract for this effort has expired, the system continues to be used in part to demonstrate compulsator driven railgun technology. This system has performed seven single shots using identical control settings for each shot, which is the first such experience using a compulsator driven railgun system. This paper describes the experimental set-up for the demonstrations and compares the generator, converter, gun switch, and launcher performances for each shot.
引用
收藏
页码:388 / 393
页数:6
相关论文
共 50 条
  • [31] A framework of automatic testing system for electromagnetic compatibility
    Cao Cheng
    Su Donglin
    Dai Fei
    2007 4TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY PROCEEDING: EMC 2007, 2007, : 279 - 283
  • [32] Field testing of the surface electromagnetic prospecting system
    Qing-Yun Di
    Chang-Min Fu
    Zhi-Guo An
    Cheng Xu
    Ya-Lu Wang
    Zhong-Xing Wang
    Applied Geophysics, 2017, 14 : 449 - 458
  • [33] Design, implementation and testing of an electromagnetic levitation system
    Department of Electrical Engineering, National Institute of Technology, Durgapur 713 209, India
    不详
    不详
    J Inst Eng India: Electr Eng Div, 2008, JUNE (9-16):
  • [34] Field testing of the surface electromagnetic prospecting system
    Di Qing-Yun
    Fu Chang-Min
    An Zhi-Guo
    Xu Cheng
    Wang Ya-Lu
    Wang Zhong-Xing
    APPLIED GEOPHYSICS, 2017, 14 (03) : 449 - 458
  • [35] Interior Ballistics Two-Phase Reactive Flow Model Applied to Small Caliber Projectile-Gun System
    Bougamra, Ahmed
    Lu, Huilin
    PROPELLANTS EXPLOSIVES PYROTECHNICS, 2015, 40 (05) : 720 - 728
  • [36] MANUFACTURING AND TESTING OF AN AIR-CORE COMPULSATOR DRIVEN 0.60 CALIBER RAILGUN SYSTEM
    KITZMILLER, JR
    FAIDLEY, RW
    FULLER, RL
    HEADIFEN, RN
    THELEN, RF
    IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (01) : 441 - 446
  • [37] Survivability Testing a Gun Hard MEMS IMU/GPS Navigation System
    Sheard, Keith
    Tidd, James
    Scaysbrook, Ian
    Keynan, Tsafrir
    Fong, Kok Chung
    PROCEEDINGS OF THE 19TH INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2006), 2006, : 168 - 175
  • [38] TESTING OF AN AIR-CORE COMPULSATOR DRIVEN 0.60-CALIBER RAILGUN SYSTEM
    FULLER, RL
    KITZMILLER, JR
    THELEN, RF
    IEEE TRANSACTIONS ON MAGNETICS, 1995, 31 (01) : 52 - 55
  • [39] Interior Ballistics Two-Phase Reactive Flow Model Applied to Large Caliber Guided Projectile-Gun System
    Rashad, Mahmoud
    Zhang, XiaoBing
    El Sadek, Hazem
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [40] Inductive electromagnetic soil salinity testing system - a report
    不详
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2000, 59 (05): : 431 - 432