Wave front migration of endothelial cells in a bone-implant interface

被引:7
|
作者
Khalil, Georges [1 ]
Lorthois, Sylvie [1 ]
Marcoux, Manuel [1 ]
Mansat, Pierre [1 ,2 ]
Swider, Pascal [1 ]
机构
[1] IMFT UMR CNRS 5502, F-31400 Toulouse, France
[2] Univ Toulouse, Toulouse Univ Hosp, Toulouse, France
关键词
Implant fixation; Angiogenesis; Endothelial cells; Growth factor; Reactive transport; GROWTH-FACTOR; EXTRACELLULAR-MATRIX; MELANOMA-CELLS; ANGIOGENESIS; FIBRONECTIN; IDENTIFICATION; LOCALIZATION; CHEMOTAXIS; STRATEGIES; MORPHOLOGY;
D O I
10.1016/j.jbiomech.2011.05.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The neo-vascularization of the host site is crucial for the primary fixation and the long-term stability of the bone-implant interface. Our aim was to investigate the progression of endothelial cell population in the first weeks of healing. We proposed a theoretical reactive model to study the role of initial conditions, random motility, haptotaxis and chemotaxis in interactions with fibronectin factors and transforming angiogenic factors. The application of governing equations concerned a canine experimental implant and numerical experiments based upon statistical designs of experiments supported the discussion. We found that chemotaxis due to transforming angiogenic factors was attracting endothelial cells present into the host bone. Haptotaxis conditioned by fibronectin factors favored cells adhesion to the host bone. The combination of diffusive and reactive effects nourished the wave front migration of endothelial cells from the host bone towards the implant. Angiogenesis goes together with new-formed bone formation in clinics, so the similarity of distribution patterns of mineralized tissue observed in-vivo and the spatio-temporal concentration of endothelial cells predicted by the model, tended to support the reliability of our theoretical approach. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1980 / 1986
页数:7
相关论文
共 50 条
  • [21] BIOMECHANICAL STRESS ANALYSIS OF BONE-IMPLANT INTERFACE
    Fanali, S.
    Tramonte, S. U.
    Brunelli, G.
    Carinci, F.
    EUROPEAN JOURNAL OF INFLAMMATION, 2011, 9 (02) : 25 - 31
  • [22] Reflection of an ultrasonic wave on the bone-implant interface: A numerical study of the effect of the multiscale roughness
    Heriveaux, Yoann
    Vu-Hieu Nguyen
    Haiat, Guillaume
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 144 (01): : 488 - 499
  • [23] Study with speckle interferometry of bone-implant interface conditions
    Simoes, J
    Monteiro, J
    Vaz, M
    Taylor, M
    Blatcher, S
    EXPERIMENTAL MECHANICS, VOLS 1 AND 2: ADVANCES IN DESIGN, TESTING AND ANALYSIS, 1998, : 851 - 855
  • [24] ELECTRON-MICROSCOPIC STUDY OF THE BONE-IMPLANT INTERFACE
    ROLAND, K
    DUFIEF, MP
    SHERIDAN, R
    HEUSON, JA
    MICRON AND MICROSCOPICA ACTA, 1987, 18 (03): : 209 - 209
  • [25] Effect of loading frequency on deformations at the bone-implant interface
    Xie, Shuqiao
    Manda, Krishnagoud
    Pankaj, Pankaj
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (12) : 1219 - 1225
  • [26] HISTOLOGY AT THE BONE-IMPLANT INTERFACE IN CEMENTED AND NONCEMENTED ENDOPROSTHESES
    HERREN, T
    REMAGEN, W
    SCHENK, R
    ORTHOPADE, 1987, 16 (03): : 239 - 251
  • [28] Titania nanotubes for orchestrating osteogenesis at the bone-implant interface
    Gulati, Karan
    Maher, Shaheer
    Findlay, David M.
    Losic, Dusan
    NANOMEDICINE, 2016, 11 (14) : 1847 - 1864
  • [29] Ultrasonic Interferometric Procedure for Quantifying the Bone-Implant Interface
    Luetzelberger, Jan
    Arneth, Philipp
    Franck, Alexander
    Drese, Klaus Stefan
    SENSORS, 2023, 23 (13)
  • [30] Optimization of stress distribution of bone-implant interface (BII)
    Zhang, Chunyu
    Zeng, Chunyu
    Wang, Zhefu
    Zeng, Ting
    Wang, Yuehong
    BIOMATERIALS ADVANCES, 2023, 147