Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries

被引:18
|
作者
Tang, Hehan [1 ]
Hu, Na [1 ]
Yuan, Yuan [1 ]
Xia, Chunchao [1 ]
Liu, Xiumin [1 ]
Zuo, Panli [2 ]
Stalder, Aurelien F. [3 ]
Schmidt, Michaela [4 ]
Zhou, Xiaoyue [3 ]
Song, Bin [1 ]
Sun, Jiayu [1 ]
机构
[1] Sichuan Univ, Dept Radiol, West China Hosp, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
[2] Siemens Healthineers Ltd, MR Collaborat NEA, Beijing, Peoples R China
[3] Siemens Healthineers Ltd, MR Collaborat NEA, Shanghai, Peoples R China
[4] Siemens Healthineers GmbH, Erlangen, Germany
关键词
Time-of-Flight (TOF); Magnetic resonance angiography (MRA); Intracranial vessels; Sparse; Iterative reconstruction; HEART CORONARY MRA; DATA-ACQUISITION; FOLLOW-UP; QUALITY; SENSE;
D O I
10.3348/kjr.2017.0634
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the image quality of three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) with sparse undersampling and iterative reconstruction (sparse TOF) with that of conventional TOF MRA. Materials and Methods: This study included 56 patients who had undergone sparse TOF MRA for intracranial artery evaluation on a 3T MR scanner. Conventional TOF MRA scans were also acquired from 29 patients with matched acquisition times and another 27 patients with matched scanning parameters. The image quality was scored using a five-point scale based on the delineation of arterial vessel segments, artifacts, overall vessel visualization, and overall image quality by two radiologists independently, and the data were analyzed using the non-parametric Wilcoxon signed-rank test. Contrast ratios (CRs) of vessels were compared using the paired t test. Interobserver agreement was calculated using the kappa test. Results: Compared with conventional TOE at the same spatial resolution, sparse TOE with an acceleration factor of 3.5 could reduce acquisition time by 40 degrees Io and showed comparable image quality. In addition, when compared with conventional TOF with the same acquisition time, sparse TOF with an acceleration factor of 5 could also achieve higher spatial resolution, better delineation of vessel segments, fewer artifacts, higher image quality, and a higher CR (p < 0.05). Good-to-excellent interobserver agreement (kappa: 0.65-1.00) was obtained between the two radiologists. Conclusion: Compared with conventional TOE, sparse TOF can achieve equivalent image quality in a reduced duration. Furthermore, using the same acquisition time, sparse TOF could improve the delineation of vessels and decrease image artifacts.
引用
收藏
页码:265 / 274
页数:10
相关论文
共 50 条
  • [41] Spiral time-of-flight magnetic resonance angiography for intracranial vascular imaging: performance compared to conventional Cartesian angiogram
    Xu, Lina
    Wu, Jian
    Kang, Taishan
    Lin, Liangjie
    Lv, Shaomao
    Lin, Jianzhong
    Feng, Zhipeng
    Cai, Congbo
    Chen, Zhong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (05) : 3417 - 3431
  • [42] Development and validation of visual grading system for stenosis in intracranial atherosclerotic disease on time-of-flight magnetic resonance angiography
    You, Sung-Hye
    Kim, Byungjun
    Yang, Kyung-Sook
    Kim, Bo Kyu
    Woo, Seungtae
    Park, Sang Eun
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2781 - 2790
  • [43] Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils
    H. E. Westerlaan
    A. M. van der Vliet
    J. M. Hew
    L. C. Meiners
    J. D. M. Metzemaekers
    J. J. A. Mooij
    M. Oudkerk
    Neuroradiology, 2005, 47 : 622 - 629
  • [44] Joint Partial Fourier and Compressed Sensing Reconstruction for Accelerated Time-of-Flight MR Angiography
    Kilic, Toygan
    Cukur, Tolga
    Algin, Oktay
    Saritas, Emine Ulku
    2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [45] Ophthalmic Arteries Arising from the Bilateral Anterior Cerebral Arteries Diagnosed by Three-Dimensional Time-of-Flight Magnetic Resonance Angiography
    Ogul, Hayri
    WORLD NEUROSURGERY, 2020, 134 : 228 - 230
  • [46] Compressed sensing time-of-flight magnetic resonance angiography with high spatial resolution for evaluating intracranial aneurysms: comparison with digital subtraction angiography
    Kim, Donghyun
    Heo, Young Jin
    Jeong, Hae Woong
    Baek, Jin Wook
    Shin, Gi Won
    Jin, Sung-Chul
    Baek, Hye Jin
    Ryu, Kyeong Hwa
    Kim, Kang Soo
    Kim, InSeong
    NEURORADIOLOGY JOURNAL, 2021, 34 (03): : 213 - 221
  • [47] Computational Fluid Dynamics Simulations Based on Time-of-Flight Magnetic Resonance Angiography
    Topkara, Ahmet
    Okeer, Emre
    Hakyemez, Bahattin
    Isik, Esin Ozturk
    Olcay, Bahadir
    2014 18TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2014,
  • [48] Editorial for "Quantitative Time-of-Flight Head Magnetic Resonance Angiography of Cerebrovascular Disease"
    Balu, Niranjan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (01) : 413 - 414
  • [49] Contrast-enhanced Magnetic Resonance Angiography in Stroke Diagnostics Additional Information Compared with Time-of-Flight Magnetic Resonance Angiography?
    Alfke, K.
    Jensen, U.
    Pool, C.
    Rohr, A.
    Bruening, R.
    Weber, J.
    Bartsch, T.
    Stingele, R.
    Jansen, O.
    CLINICAL NEURORADIOLOGY, 2011, 21 (01) : 5 - 10
  • [50] Comparison Study between Three-dimensional Time-of-Flight Magnetic Resonance Angiography and Rotational Digital Subtraction Angiography in Detection of Intracranial Aneurysms
    Li, Ming-Hua
    Li, Yong-Dong
    Chen, Shi-Wen
    Hu, Ding-Jun
    Fang, Chun
    CIRCULATION, 2009, 120 (18) : S1483 - S1483