Performance evaluation of a recently developed water-based condensation particle counter

被引:37
|
作者
Biswas, S
Fine, PM
Geller, MD
Hering, SV
Sioutas, C
机构
[1] Univ So Calif, Dept Civil & Environm Engn, Los Angeles, CA 90089 USA
[2] Aerosol Dynam Inc, Berkeley, CA USA
关键词
D O I
10.1080/027868290953173
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study provides an intercomparison of the performance of a newly developed water-based condensation particle counter (WCPC) and a more widely used butanol-based CPC (TSI 3022A). Four test aerosols (ammonium nitrate, ammonium sulfate, adipic acid, and glutaric acid) were generated and tested in the laboratory before the instruments were deployed at four field locations (USC/downtown LA, I-710 Freeway, Pacific coast, and Los Angeles International Airport). Both instruments sampled the same incoming aerosol. Selected experiments utilized a differential mobility analyzer to select a particle size upstream of the CPCs. Evaluation of performance was based on the response of the instruments to varying particle composition, concentrations, and size. The results indicated good correlation between the two CPCs, with R-2 values ranging from 0.74-0.99. Good agreement was found between the two instruments for particle concentrations between 0 and 40,000 particles/cm(3), with W-CPC/TSI 3022A ratios between 0.8 and 1.2. Due to differences in the photometric mode calibration of these instruments, the ratio drops to 0.6-0.8 between 40,000-100,000 particles/cm(3). However, the ratio rises again for lab aerosols above 100,000 particles/cm(3) to 1.0-1.1. Results of this evaluation show that the W-CPC is a reliable particle-counting technology for particle concentrations encountered downstream of a DMA as well as in some ambient environments (< 40,000 particles/cm(3)).
引用
收藏
页码:419 / 427
页数:9
相关论文
共 50 条
  • [41] Operation and performance of a differential mobility particle sizer and a TSI 3010 condensation particle counter at stratospheric temperatures and pressures
    Seifert, M
    Tiede, R
    Schnaiter, M
    Linke, C
    Möhler, O
    Schurath, U
    Ström, J
    JOURNAL OF AEROSOL SCIENCE, 2004, 35 (08) : 981 - 993
  • [43] Water-based muds using synthetic polymers developed for high temperature drilling
    Plank, Johann P.
    Oil and Gas Journal, 1992, 90 (09): : 40 - 45
  • [44] Performance Analysis of a New Water-based Microcooling System
    Musmar, Sa'ed A.
    Al-Halhouli, A. T.
    Tlili, Iskander
    Buettgenbach, S.
    EXPERIMENTAL HEAT TRANSFER, 2016, 29 (04) : 485 - 499
  • [45] Heat transfer performance of water-based electrospray cooling
    Kim, Yunseo
    Jung, Sangwoo
    Kim, Soyeon
    Choi, Seung Tae
    Kim, Minsung
    Lee, Hyoungsoon
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2020, 118
  • [46] An experimental investigation of the boiling performance of water-based nanofluids
    Sajith, V.
    Madhusoodanan, M. R.
    Sobhan, C. B.
    PROCEEDINGS OF THE MICRO/NANOSCALE HEAT TRANSFER INTERNATIONAL CONFERENCE 2008, PTS A AND B, 2008, : 555 - 561
  • [47] Rheological evaluation of water-based drilling fluids with nanosilice
    Eusebio Gallardo, Felipe
    Erdmann, Eleonora
    Abalos, Roxana
    MATERIA-RIO DE JANEIRO, 2018, 23 (02):
  • [48] An Evaluation Toolkit for Small NGOs in Water-based Development
    Lu, Stephanie K.
    Elliott, Susan J.
    Majowicz, Shannon E.
    Perlman, Christopher M.
    JOURNAL OF INTERNATIONAL DEVELOPMENT, 2018, 30 (03) : 457 - 473
  • [49] EFFICIENCY EVALUATION OF BREAKERS IN WATER-BASED FRACTURING FLUIDS
    Carrascal, Fabian A.
    Del Pilar Pachon, Zarith
    Daniel Molina, V
    FUENTES EL REVENTION ENERGETICO, 2014, 12 (01): : 47 - 51
  • [50] Editorial: Training, performance and rehabilitation in water-based sports
    Joulia, Fabrice
    Daly, Daniel
    Guimard, Alexandre
    FRONTIERS IN PHYSIOLOGY, 2023, 14