A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection

被引:24
|
作者
Xia, Yanyan [1 ]
Shen, Han [1 ]
Zhu, Yefei [2 ]
Xu, Hongpan [1 ]
Li, Zhiyang [1 ,3 ]
Si, Jin [1 ]
机构
[1] Nanjing Univ, Sch Med, Dept Clin Lab, Affiliated Drum Tower Hosp, Nanjing 210008, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 2, Dept Clin Lab, Nanjing 210011, Peoples R China
[3] Southeast Univ, Sch Biol Sci & Med Engn, State Key Lab Bioelect, Nanjing 210096, Jiangsu, Peoples R China
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
HEPATOCELLULAR-CARCINOMA; SERUM MARKER; GP73; ASSAY; NANOPARTICLES; RECURRENCE; PROGNOSIS; DIAGNOSIS; BIOMARKER; GOLPH2;
D O I
10.1038/srep40090
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Golgi protein 73 (GP73) is a novel and potential marker for diagnosing hepatocellular carcinoma (HCC) that has been found to be abnormally elevated in liver disease. A latex particle-enhanced turbidimetric immunoassay (LTIA) was recently introduced and licensed for application in a variety of automated clinical chemistry analyzers. However, no studies have reported sufficient data on analytical performance of this method when using 3 monoclonal antibodies for GP73 measurement. The experimental conditions were firstly optimized and range of linearity, diagnostic potential, clinical relevance were compared with the LTIA based on polyclonal antibodies and ELISA. Dilution tests for the LTIA using 3 monoclonal antibodies produced a calibration curve from 10 to 350 ng/mL while the polyclonal antibodies produced the curve from 20 to 320 ng/mL. The detection limit was achieved at 1.82 ng/mL concentration. Within-run CV was obtained in the range of 1.5-2.9% and ROC curves indicated sensitivity and specificity of the LTIA based on 3 monoclonal antibodies were 96.7% and 93.3%, respectively, higher than for the polyclonal antibodies (94.6% and 72.4%) and ELISA (70.0% and 83.3%). Therefore, the LTIA assay based on 3 monoclonal antibodies is thus applicable in quantification of GP73 concentration in automated biochemistry analyzers.
引用
收藏
页数:10
相关论文
共 20 条
  • [11] Evaluation of a fully-automated particle-enhanced turbidimetric immunoassay for the measurement of plasma lipoprotein (a).: Population-based reference values in an area with low incidence of cardiovascular disease
    Simó, JM
    Camps, J
    Gómez, F
    Ferré, N
    Joven, J
    CLINICAL BIOCHEMISTRY, 2003, 36 (02) : 129 - 134
  • [12] Sensitive and rapid detection of tetrodotoxin based on gold nanoflower-and latex microsphere-labeled monoclonal antibodies
    Huang, Yongming
    Xu, Aidi
    Xu, Yang
    Wu, Huijuan
    Sun, Menghan
    Madushika, Lakshani
    Wang, Rongzhi
    Yuan, Jun
    Wang, Shihua
    Ling, Sumei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [13] SENSITIVE DETECTION OF HANTAVIRUSES BY BIOTIN-STREPTAVIDIN ENHANCED IMMUNOASSAYS BASED ON BANK VOLE MONOCLONAL-ANTIBODIES
    LUNDKVIST, A
    HORLING, J
    BJORSTEN, S
    NIKLASSON, B
    JOURNAL OF VIROLOGICAL METHODS, 1995, 52 (1-2) : 75 - 86
  • [14] Quantitative and sensitive detection of the SARS-CoV spike protein using bispecific monoclonal antibody-based enzyme-linked immunoassay
    Sunwoo, Hoon H.
    Palaniyappan, Arivazhagan
    Ganguly, Advaita
    Bhatnagar, Pravin K.
    Das, Dipankar
    El-Kadi, Ayman O. S.
    Suresh, Mavanur R.
    JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (01) : 72 - 78
  • [15] Highly sensitive detection of three protein toxins via SERS-lateral flow immunoassay based on SiO2@Au nanoparticles
    Jia, Xiaofei
    Wang, Keli
    Li, Xinying
    Liu, Zhenzhen
    Liu, Ye
    Xiao, Rui
    Wang, Shengqi
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2022, 41
  • [16] A subtype-specific peptide-based enzyme immunoassay for detection of antibodies to the G protein of human respiratory syncytial virus is more sensitive than routine serological tests
    Langedijk, JPM
    Brandenburg, AH
    Middel, WGJ
    Osterhaus, AB
    Meloen, RH
    vanOirschot, JT
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (07) : 1656 - 1660
  • [17] A signal enhanced lateral flow immunoassay based on core-shell quantum dots labeled antibody and antigen for sensitive detection of CP4-EPSPS protein
    Zeng, Haijuan
    Zhang, Yan
    Zhang, Minghao
    Liu, Hua
    Liu, Juan
    Zhu, Lemei
    Wang, Jinbin
    Guo, Wenbo
    MICROCHEMICAL JOURNAL, 2025, 209
  • [18] SERS-based lateral flow immunoassay for sensitive and simultaneous detection of anti-SARS-CoV-2 IgM and IgG antibodies by using gap-enhanced Raman nanotags
    Chen, Shiliang
    Meng, Liuwei
    Wang, Litong
    Huang, Xixi
    Ali, Shujat
    Chen, Xiaojing
    Yu, Mingen
    Yi, Ming
    Li, Limin
    Chen, Xi
    Yuan, Leiming
    Shi, Wen
    Huang, Guangzao
    Sensors and Actuators B: Chemical, 2021, 348
  • [19] SERS-based lateral flow immunoassay for sensitive and simultaneous detection of anti-SARS-CoV-2 IgM and IgG antibodies by using gap-enhanced Raman nanotags
    Chen, Shiliang
    Meng, Liuwei
    Wang, Litong
    Huang, Xixi
    Ali, Shujat
    Chen, Xiaojing
    Yu, Mingen
    Yi, Ming
    Li, Limin
    Chen, Xi
    Yuan, Leiming
    Shi, Wen
    Huang, Guangzao
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 348
  • [20] Detection of a Thermal Stable-Soluble Protein (TSSP) as a Marker of Peanut Adulteration Using a Highly Sensitive Indirect Enzyme-Linked Immunosorbent based on Monoclonal Antibodies
    Kim, Sol-A
    Toushik, Sazzad Hossen
    Lee, Jeong-Eun
    Shim, Won-Bo
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2023, 33 (09) : 1170 - 1178