Real-time ultrasound-guided placement of peripherally inserted central venous catheter without fluoroscopy

被引:14
|
作者
Nakamuta, Soshi [1 ,2 ]
Nishizawa, Toshihiro [1 ]
Matsuhashi, Shiori [2 ]
Shimizu, Arata [2 ]
Uraoka, Toshio [1 ]
Yamamoto, Masato [2 ]
机构
[1] Natl Hosp Org Tokyo Med Ctr, Dept Gastroenterol, Tokyo, Japan
[2] JCHO Tokyo Takanawa Hosp, Div Cardiol, Tokyo, Japan
来源
JOURNAL OF VASCULAR ACCESS | 2018年 / 19卷 / 06期
关键词
Peripherally inserted central venous catheter; tip malposition; ultrasound; INFECTIONS; PREVENTION; POSITION; TRIAL;
D O I
10.1177/1129729818765057
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background and aim: Malposition of peripherally inserted central catheters placed at the bedside is a well-recognized phenomenon. We report the success rate of the placement of peripherally inserted central catheters with ultrasound guidance for tip positioning and describe the knacks and pitfalls. Materials and methods: We retrospectively reviewed the medical case charts of 954 patients who received peripherally inserted central catheter procedure. Patient clinical data included success rate of puncture, detection rate of tip malposition with ultrasonography, adjustment rate after X-ray, and success rate of peripherally inserted central catheter placement. Results: The success rate of puncture was 100% (954/954). Detection rate of tip malposition with ultrasonography was 82.1% (78/95). The success rate of ultrasound-guided tip navigation was 98.2% (937/954). The success rate of ultrasound-guided tip location was 98.0% (935/954). Adjustment rate after X-ray was 1.79% (17/952). The final success rate of peripherally inserted central catheter placement was 99.8% (952/954). Conclusion: Ultrasound guidance for puncturing and tip positioning is a promising option for the placement of peripherally inserted central catheters. Ultrasound guidance could dispense with radiation exposure and the transfer of patients to the X-ray department.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 50 条
  • [41] Ultrasound guided central venous catheter placement in neurosurgery
    Jee Jian
    Pirjo H Manninen
    Michael Lukins
    Nkihu Merah
    Canadian Journal of Anesthesia, 2005, 52 (Suppl 1): : A194 - A194
  • [42] Changes in Central Venous Catheter Use in the Hematology Unit with the Introduction of Ultrasound Guidance and a Peripherally Inserted Central Venous Catheter
    Utsu, Yoshikazu
    Masuda, Shinichi
    Watanabe, Reiko
    Arai, Hironori
    Nakamura, Ayako
    Matsui, Shinichirou
    Izumi, Shintarou
    Aotsuka, Nobuyuki
    INTERNAL MEDICINE, 2021, 60 (17) : 2765 - 2770
  • [43] Influence of arm position on catheter placement during real-time ultrasound-guided right infraclavicular proximal axillary venous catheterization
    Ahn, J. H.
    Kim, I. S.
    Shin, K. M.
    Kang, S. S.
    Hong, S. J.
    Park, J. H.
    Kim, H. J.
    Lee, S. H.
    Kim, D. Y.
    Jung, J. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (03) : 363 - 369
  • [44] Establishing an ultrasound guided peripherally inserted central catheter (PICC) insertion service
    Parkinson, R
    Gandhi, M
    Harper, J
    Archibald, C
    CLINICAL RADIOLOGY, 1998, 53 (01) : 33 - 36
  • [45] Unusual complication of peripherally inserted central venous catheter placement: the left pericardiophrenic vein
    Krishnan, A
    Cacciarelli, A
    Gibson, D
    PEDIATRIC RADIOLOGY, 2004, 34 (02) : 180 - 181
  • [46] Safety and Feasibility of Electrocardiogram-Guided Tip Positioning Combined with Ultrasound-Guided Placement of Peripherally Inserted Central Catheter Performed in Severe Brain Injury Patients
    Xiaoli Jiang
    Xiangzhi Li
    Bin Ouyang
    Lingyan Yan
    Qiaofang Gu
    Meihua Mei
    Lingyan Wang
    Intensive Care Research, 2024, 4 (3): : 155 - 161
  • [47] Peripherally Inserted Central Catheter Placement in Infants and Children
    Braswell, Leah E.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 14 (04) : 204 - 211
  • [48] Peripherally inserted central catheter placement @ the speed of sound
    Hunter, Mark
    NUTRITION IN CLINICAL PRACTICE, 2007, 22 (04) : 406 - 411
  • [49] Placement of a peripherally inserted central catheter into the azygous vein
    Franklin, Iain
    Gilmore, Christopher
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (02) : 160 - 162
  • [50] Electromagnetically tracked placement of a peripherally inserted central catheter
    Johns Hopkins University, Dept. of Biomedical Engineering, Baltimore, MD, United States
    不详
    不详
    SPIE - International Society for Optical Engineering, 1600, 724-728 (2004):