We present a novel probe-based portable clinical system for early detection and margin demarcation of melanoma and non-melanoma skin cancers. The system collects both white light reflectance and fluorescence from tissue in real time. We use gated detection to eliminate effects of room lights and make the system clinically compatible. Instrument control and spectral calibration is automated using a personal computer. The total acquisition time for data collection is less than a second. We use a spectrally-constrained inverse model for our probe geometry to fit the diffuse reflectance and extract hemoglobin content, oxygen saturation, tissue micro-architecture and melanin content. We demonstrate system performance and present results from tissue simulating phantoms. The mean rms errors in estimating scattering and absorption coefficients in tissue phantoms over a physiologically relevant range were 9.8% and 11.8% respectively. Using a photon migration model and least-squares regression we were able to extract the intrinsic fluorescence line shapes and estimate fluorophore concentrations from measured fluorescence spectra with an rms error of less than 10%.
引用
收藏
页码:R8480 / R8480
页数:10
相关论文
共 50 条
  • [31] Relations in biomedical ontologies -: art. no. R46
    Smith, B
    Ceusters, W
    Klagges, B
    Köhler, J
    Kumar, A
    Lomax, J
    Mungall, C
    Neuhaus, F
    Rector, AL
    Rosse, C
    GENOME BIOLOGY, 2005, 6 (05)
  • [32] Leonardo's laptop - art. no. R114
    Petrelli, D
    INFORMATION RESEARCH-AN INTERNATIONAL ELECTRONIC JOURNAL, 2003, 9 (01):
  • [33] Spin Hall Effect - art. no. 70360R
    Dyakonov, M. I.
    SPINTRONICS, 2008, 7036 : R360 - R360
  • [34] K-correlation power spectral density & surface scatter model - art. no. 62910R
    Dittman, Michael G.
    Optical Systems Degradation, Contamination, and Stray Light: Effects, Measurements, Control II, 2006, 6291 : R2910 - R2910
  • [35] SOFIE instrument model and performance comparison - art. no. 62970P
    Hansen, Scott
    Shumway, Andrew
    Fish, Chad
    Peterson, Jim
    Mace, Peter
    Cook, James
    Nelsen, Joel
    Hooper, Dale
    Young, Quinn
    Wassom, Steve
    Kemp, John
    Gordley, Larry
    Hervig, Mark
    Infrared Spaceborne Remote Sensing XIV, 2006, 6297 : P2970 - P2970
  • [36] The Dark Energy Survey instrument design - art. no. 62692C
    Flaugher, B.
    Ground-based and Airborne Instrumentation for Astronomy, Pts 1- 3, 2006, 6269 : C2692 - C2692
  • [37] VLT VISIR - Controlling data quality and instrument performance - art. no. 627026
    Dobrzycka, Danuta
    Smette, Alain
    Sterzik, Michael
    Lundin, Lars
    Jung, Yves
    Siebenmorgen, Ralf
    Observatory Operations: Strategies, Processes, and Systems, 2006, 6270 : 27026 - 27026
  • [38] VLT(I) instrument operations and maintenance at the Paranal Observatory - art. no. 627009
    Kaufer, A.
    Alvarez, J. L.
    Bendek, E.
    Caruso, F.
    Castillo, R.
    Jimenez, J.
    Gillet, G.
    Haddad, N.
    Leiva, A.
    Marchesi, M.
    Mardones, P.
    Riquelme, M.
    Robert, P.
    Weilenmann, U.
    Observatory Operations: Strategies, Processes, and Systems, 2006, 6270 : 27009 - 27009
  • [39] The instrument model: performance prediction simulator for SIM PlanetQuest - art. no. 667509
    Morales, Mauricio J.
    Fathpour, Nanaz
    OPTICAL MODELING AND PERFORMANCE PREDICTIONS III, 2007, 6675 : 67509 - 67509
  • [40] Tracking perturbations in Boolean networks with spectral methods -: art. no. 026137
    Kesseli, J
    Rämö, P
    Yli-Harja, O
    PHYSICAL REVIEW E, 2005, 72 (02):