Clinical instrument for spectral diagnosis of cutaneous malignancy - art. no. 68480R

被引:2
|
作者
Rajaram, Narasimhan [1 ]
Aramil, Timothy J. [1 ]
Lee, Kelvin [1 ]
Tunnell, James W. [1 ]
机构
[1] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
关键词
diffuse reflectance; intrinsic fluorescence; tissue optical properties;
D O I
10.1117/12.759709
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a novel probe-based portable clinical system for early detection and margin demarcation of melanoma and non-melanoma skin cancers. The system collects both white light reflectance and fluorescence from tissue in real time. We use gated detection to eliminate effects of room lights and make the system clinically compatible. Instrument control and spectral calibration is automated using a personal computer. The total acquisition time for data collection is less than a second. We use a spectrally-constrained inverse model for our probe geometry to fit the diffuse reflectance and extract hemoglobin content, oxygen saturation, tissue micro-architecture and melanin content. We demonstrate system performance and present results from tissue simulating phantoms. The mean rms errors in estimating scattering and absorption coefficients in tissue phantoms over a physiologically relevant range were 9.8% and 11.8% respectively. Using a photon migration model and least-squares regression we were able to extract the intrinsic fluorescence line shapes and estimate fluorophore concentrations from measured fluorescence spectra with an rms error of less than 10%.
引用
收藏
页码:R8480 / R8480
页数:10
相关论文
共 50 条
  • [1] Design and validation of a clinical instrument for spectral diagnosis of cutaneous malignancy
    Rajaram, Narasimhan
    Aramil, Timothy J.
    Lee, Kelvin
    Reichenberg, Jason S.
    Nguyen, Tri H.
    Tunnell, James W.
    APPLIED OPTICS, 2010, 49 (02) : 142 - 152
  • [2] Automated method for RNFL segmentation in spectral domain OCT - art. no. 68480N
    Paranjape, Amit S.
    Elmaanaoui, Badr
    Dewelle, Jordan
    Rylander, H. Grady
    Milner, Thomas E.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VI, 2008, 6848 : N8480 - N8480
  • [3] Nonlinear optical measurements of glucose concentration - art. no. 68480J
    Yakovlev, V. V.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VI, 2008, 6848 : J8480 - J8480
  • [4] Autofluorescence spectroscopic imaging for laryngeal cancer detection - art. no. 68480G
    Kan, Lin
    Zheng, Wei
    Huang, Zhiwei
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VI, 2008, 6848 : G8480 - G8480
  • [5] Multiplexed BioCD for prostate specific antigen detection - art. no. 68480S
    Wang, Xuefeng
    Zhao, Ming
    Nolte, David D.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VI, 2008, 6848 : S8480 - S8480
  • [6] Electromagnetic signals and spectral measurements - art. no. 659410
    Moskaletz, Oleg D.
    Lasers for Measurements and Information Transfer 2006, 2007, 6594 : 59410 - 59410
  • [7] Spectral Features, effects and cures - art. no. 667703
    van Brug, Hedser
    Lacoste, Gregory Bazalgette Courreges
    EARTH OBSERVING SYSTEMS XII, 2007, 6677 : 67703 - 67703
  • [8] Attosecond spectral shearing interferometry -: art. no. 073902
    Quéré, F
    Itatani, J
    Yudin, GL
    Corkum, PB
    PHYSICAL REVIEW LETTERS, 2003, 90 (07)
  • [9] Malignancy after renal transplantation: art. no. E5
    Zeier, M
    Hartschuh, W
    Wiesel, M
    Lehnert, T
    Ritz, E
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 39 (01)
  • [10] Discrepancy games -: art. no. R51
    Alon, N
    Krivelevich, M
    Spencer, J
    Szabó, T
    ELECTRONIC JOURNAL OF COMBINATORICS, 2005, 12 (01):