Impact of new lightning and switching impulse definitions on the test results for insulation systems

被引:1
|
作者
Gockenbach, E [1 ]
机构
[1] Univ Hannover, Schering Inst, Div High Voltage Engn, Inst Elect Power Syst, D-30167 Hannover, Germany
关键词
D O I
10.1109/ISEIM.2005.193492
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The revision of the relevant recommendations allows to introduce new definitions of lightning impulse parameters. Experimental results have shown that the breakdown voltage of insulating materials depends on the frequency of the oscillations or overshoot near the peak and that this behaviour can be described by a test voltage factor k. Different procedures to evaluate the test voltage and the time parameters of a lightning impulse voltage are described. Filtering methods leads to very good results in determining the test voltage, but at the moment differences exists in the determination of the time parameters of a lightning impulse. The time to peak of a switching impulse can also be determined more accurate by a procedure similar to lightning impulses. The new definitions seems not to influence the results of impulse tests on insulation systems but they contribute very much to the reproducibility of the tests results.
引用
收藏
页码:792 / 795
页数:4
相关论文
共 50 条
  • [21] K-factor Value and Front Time Related Characteristics of UHV-class Air Insulation for Positive Polarity Lightning Impulse Test
    Ueta, Genyo
    Tsuboi, Toshihiro
    Okabe, Shigemitsu
    Shimizu, Yoshinori
    Hino, Etsuhiro
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (03) : 877 - 885
  • [22] TEST-RESULTS AND EVALUATION OF INTEGRATED COLLECTOR STORAGE-SYSTEMS WITH TRANSPARENT INSULATION
    SCHMIDT, C
    GOETZBERGER, A
    SCHMID, J
    SOLAR ENERGY, 1988, 41 (05) : 487 - 494
  • [23] K-Factor Value and Front-Time-Related Characteristics in Negative Polarity Lightning Impulse Test for UHV-Class Air Insulation
    Tsuboi, Toshihiro
    Ueta, Genyo
    Okabe, Shigemitsu
    Shimizu, Yoshinori
    Ishikura, Takahiko
    Hino, Etsuhiro
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 1148 - 1155
  • [24] A New Test Method for Assessing the Impact of Thermal Cycling on Hydrogenerator Stator Insulation
    Brugger, Thomas
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [25] New Results on Stability Analysis of Markovian Switching Singular Systems
    Xiao, Xiaoqing
    Park, Ju H.
    Zhou, Lei
    Lu, Guoping
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2019, 64 (05) : 2084 - 2091
  • [26] Evaluation of Overshoot Rate of Lightning Impulse Withstand Voltage Test Waveform Based on New Base Curve Fitting Methods
    Ueta, Genyo
    Tsuboi, Toshihiro
    Takami, Jun
    Okabe, Shigemitsu
    Hirose, Hideo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (04) : 1336 - 1345
  • [27] New results on stability of random coupled systems on networks with Markovian switching
    Wang, Pengfei
    Wang, Mengxin
    Su, Huan
    NONLINEAR ANALYSIS-HYBRID SYSTEMS, 2019, 32 : 306 - 319
  • [28] TEST RESULTS ON HOMOGENIZING PROPERTIES OF NEW TYPES OF AGITATING SYSTEMS
    HENZLER, HJ
    HOHNEL, L
    CHEMISCHE TECHNIK, 1973, 25 (01): : 23 - 27
  • [29] Comparison of test results from two separate video head impulse test systems in a cohort of patients diagnosed with a unilateral vestibular schwannoma
    Mathilde Aalling
    Regitze Kuhr Skals
    Emil Riis Abrahamsen
    Dan Dupont Hougaard
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 3185 - 3193
  • [30] Comparison of test results from two separate video head impulse test systems in a cohort of patients diagnosed with a unilateral vestibular schwannoma
    Aalling, Mathilde
    Skals, Regitze Kuhr
    Abrahamsen, Emil Riis
    Hougaard, Dan Dupont