Impact of new lightning and switching impulse definitions on the test results for insulation systems

被引:1
|
作者
Gockenbach, E [1 ]
机构
[1] Univ Hannover, Schering Inst, Div High Voltage Engn, Inst Elect Power Syst, D-30167 Hannover, Germany
关键词
D O I
10.1109/ISEIM.2005.193492
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The revision of the relevant recommendations allows to introduce new definitions of lightning impulse parameters. Experimental results have shown that the breakdown voltage of insulating materials depends on the frequency of the oscillations or overshoot near the peak and that this behaviour can be described by a test voltage factor k. Different procedures to evaluate the test voltage and the time parameters of a lightning impulse voltage are described. Filtering methods leads to very good results in determining the test voltage, but at the moment differences exists in the determination of the time parameters of a lightning impulse. The time to peak of a switching impulse can also be determined more accurate by a procedure similar to lightning impulses. The new definitions seems not to influence the results of impulse tests on insulation systems but they contribute very much to the reproducibility of the tests results.
引用
收藏
页码:792 / 795
页数:4
相关论文
共 50 条
  • [1] On Site Oscillating Lightning Impulse Test and Insulation Diagnose for Power Transformers
    Zhang, Xuanrui
    Shi, Minxia
    He, Cong
    Li, Junhao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (05) : 2548 - 2550
  • [2] Droplet behavior under the impact of lightning and switching impulse voltage
    Loewe, Jens-Michael
    Hinrichsen, Volker
    Tropea, Cameron
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 443 - 447
  • [3] Adjustment of Wave Front Time and Overshoot in Lightning Impulse Test for Transformer Insulation
    Zhou, Yuanxiang
    Zhou, Zhongliu
    Xu, Huafeng
    Zhang, Xiangyu
    Zeng, Xiangjun
    Li, Shaohua
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 270 - 273
  • [4] Barrier Lightning Impulse Test For Dry Type Transformer Main Insulation Design
    Wang, Zepu
    2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2015, : 603 - 605
  • [5] Impact of time parameters of lightning impulse on the breakdown characteristics of oil paper insulation
    Sima, Wenxia
    Sun, Potao
    Yang, Ming
    Wu, Jingyu
    Hua, Jiefang
    HIGH VOLTAGE, 2016, 1 (01): : 18 - 24
  • [6] NEW METHOD FOR ASSESSMENT OF SWITCHING-IMPULSE INSULATION STRENGTH
    OUYANG, M
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1966, 113 (11): : 1835 - &
  • [7] Study on Detection Method of Transformer Winding Insulation Defects Based on Lightning Impulse Test
    Quan, Yusheng
    Ning, Zisen
    Chen, Huagui
    Yi, Bo
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 847 - +
  • [8] DISCUSSION ON NEW METHOD FOR ASSESSMENT OF SWITCHING-IMPULSE INSULATION STRENGTH
    OAKESHOT.DF
    WILKINS, JT
    DANNENBE.K
    EDWARDS, HG
    CHERRY, DM
    LIAO, TW
    RATHBUN, WH
    BARNES, HC
    CHARKOW, JH
    MCELROY, AJ
    EDWARDS, L
    FOTI, A
    KINYON, AL
    HILL, HL
    MORAN, JH
    UDO, T
    CARRARA, G
    OUYANG, M
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1967, 114 (11): : 1734 - &
  • [9] Research on the Detecting Effectiveness of On-site Lightning Impulse Test for GIS Equipment with Insulation Defects
    Wen, Tao
    Zhang, Qiaogen
    Ma, Jingtan
    Liu, Xuandong
    Wu, Zhicheng
    Zhang, Lingli
    Zhao, Junping
    Shimomura, Naoyuki
    Chen, Weijiang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (02) : 551 - 558
  • [10] On the Analysis of Impulse Test Results on Grounding Systems
    Harid, N.
    Griffiths, H.
    Mousa, S.
    Clark, D.
    Robson, S.
    Haddad, A.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (06) : 5324 - 5334