Influences of composite-composite join on light transmission characteristics of layered resin composites

被引:21
|
作者
Horie, Kanako [1 ]
Nakajima, Masatoshi [1 ]
Hosaka, Keiichi [1 ]
Kainose, Kimisuke [1 ]
Tanaka, Azusa [1 ]
Foxton, Richard M. [2 ,3 ,4 ]
Tagami, Junji [1 ,5 ]
机构
[1] Tokyo Med & Dent Univ, Dept Restorat Sci, Grad Sch Med & Dent Sci, Bunkyo Ku, Tokyo 1138549, Japan
[2] Kings Coll London, Div Conservat Dent, Kings Coll London Dent Inst, Guys Hosp, London SE1 9RT, England
[3] Kings Coll London, Div Conservat Dent, Kings Coll London Dent Inst, Kings Hosp, London SE1 9RT, England
[4] Kings Coll London, Div Conservat Dent, Kings Coll London Dent Inst, St Thomas Hosp, London SE1 9RT, England
[5] Tokyo Med & Dent Univ, Int Res Ctr Mol Sci Tooth & Bone Dis, Global Ctr Excellence Program, Bunkyo Ku, Tokyo 1138549, Japan
关键词
Layering technique; Resin composite; Diffuse light transmission; Straight-line light transmission; Translucency; Color appearance; FLUORESCENCE PROPERTIES; OXYGEN INHIBITION; DENTAL COMPOSITE; TOOTH COLOR; TRANSLUCENCY; SHADES; REPRODUCTION; OPALESCENCE; STABILITY; STRENGTH;
D O I
10.1016/j.dental.2011.10.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The purposes of this study were: (1) to determine the light transmission characteristics (straight-line and diffusion transmission) of bulk-filled and layered resin composites, and (2) to evaluate the effect of layering filling on translucency and color appearance of resin composites. Methods. Three light-cured resin composites (Estelite Sigma, Tokuyama Dental; Beautifil II, Shofu and Clearfil Majesty, Kuraray Medical) in A2 and OA2 shades were used in this study. 2 mm-thick resin composite discs were prepared by two methods; bulk filling technique (2 mm filling at one time), layering technique (two layers each 1 mm thickness). The transmitted light intensity of each resin composite disc was measured using a goniophotometer, and diffusion factor (DF), an indicator for diffuse transmission property, and peak gain (G0) for straight-line transmission were calculated from the light distribution graphs. Color was measured according to the CIELAB color scale on a spectrophotometer, and the translucency parameter (TP) and color difference (Delta E*) between bulk-filled and layered specimens were calculated. The data were statistically analyzed using three-way ANOVA, and Dunnett's T3 and t-test for post-hoc test. Results. Three-way ANOVA revealed that the layered specimens had significantly lower G0 values and higher DF values than the bulk-filled specimens, and significantly reduced TP values. The color differences (Delta E*) ranged from 1.07 to 1.85 between the bulk-filled and layered specimens. Significance. Resin composite placed in layers exhibited reduced straight-line light transmission and increased diffusion transmission compared with bulk-filled resin composite. The layering technique affected the translucency and color rendition of resin composite. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [21] High Transmission in layered composite with graphene and hyperbolic metamaterials
    Wu, Yu
    Sun, Qiang
    Qiu, Rongsheng
    Yu, Zhongwei
    Huang, Yanyan
    RESULTS IN PHYSICS, 2023, 51
  • [22] The physical characteristics of resin composite-calcium silicate interface as part of a layered/laminate adhesive restoration
    Hashem, Danya F.
    Foxton, Richard
    Manoharan, Andiappan
    Watson, Timothy F.
    Banerjee, Avijit
    DENTAL MATERIALS, 2014, 30 (03) : 343 - 349
  • [23] The effects of joint spacing on transmission characteristics of stress waves through layered composite rock masses
    Fan, Lifeng
    Shi, Xiaoying
    Wang, Meng
    Yang, Qihao
    Chen, Su
    INTERNATIONAL JOURNAL FOR NUMERICAL AND ANALYTICAL METHODS IN GEOMECHANICS, 2024, 48 (03) : 822 - 836
  • [24] Effects of light curing method and resin composite composition on composite adaptation to the cavity wall
    Yoshikawa, Takako
    Morigami, Makoto
    Sadr, Alireza
    Tagami, Junji
    DENTAL MATERIALS JOURNAL, 2014, 33 (04) : 499 - 503
  • [25] Microhardness of resin composite materials light-cured through fiber reinforced composite
    Fennis, Willem M. M.
    Ray, Noel J.
    Creugers, Nico H. J.
    Kreulen, Cees M.
    DENTAL MATERIALS, 2009, 25 (08) : 947 - 951
  • [26] Influence of Light Curing and Shade on the Microhardness of a Composite Resin
    Firoozmand, Leily Macedo
    Balducci, Ivan
    Maximo de Araujo, Maria Amelia
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2009, 9 (01): : 37 - 42
  • [27] Effects of light source on shrinkage mass of the composite resin
    Zheng, Gang
    Xu, Heng-Chang
    Zhao, Qi
    Zhongguo Shengwu Yixue Gongcheng Xuebao/Chinese Journal of Biomedical Engineering, 2002, 21 (03):
  • [28] Shrinkage force measurement of light cure composite resin
    Arakawa, Kazuo
    Mada, Toshio
    Nihon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 2009, 75 (760): : 1663 - 1667
  • [29] Resin composite properties and energy density of light cure
    Peutzfeldt, A
    Asmussen, E
    JOURNAL OF DENTAL RESEARCH, 2005, 84 (07) : 659 - 662
  • [30] Measurement of fracture energy in a light cure composite resin
    Arakawa, Kazuo
    Kato, Masaru
    Mada, Toshio
    Nihon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 2009, 75 (752): : 516 - 521