A Programmable Moving Insert for the ArcCHECK Phantom for Dose Verification of Respiratory-Gated VMAT

被引:1
|
作者
Gaede, S. [1 ,2 ]
Young, H. [3 ]
Mulligan, M. [1 ]
Jordan, K. [1 ,2 ]
机构
[1] London Reg Canc Program, London, ON, Canada
[2] Western Univ, London, ON, Canada
[3] Univ Waterloo, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1118/1.4924425
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3345 / 3345
页数:1
相关论文
共 50 条
  • [1] Dose verification for respiratory-gated volumetric modulated arc therapy
    Qian, Jianguo
    Xing, Lei
    Liu, Wu
    Luxton, Gary
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 4827 - 4838
  • [2] Verification of junction dose between VMAT arcs of total body irradiation using a Sun Nuclear ArcCHECK phantom
    Morrison, Colm T.
    Symons, Kirsty L.
    Woodings, Simon J.
    House, Michael J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (06): : 177 - 182
  • [3] Dose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study
    Jong, W. L.
    Wong, J. H. D.
    Ng, K. H.
    Ung, N. M.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [4] Implementation of respiratory-gated VMAT on a Versa HD linear accelerator
    Snyder, Jeffrey E.
    Flynn, Ryan T.
    Hyer, Daniel E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 152 - 161
  • [5] Development of a novel methodology for QA of respiratory-gated and VMAT beam delivery using Octavius 4D phantom
    Yang, Bin
    Geng, Hui
    Ding, Ying
    Kong, Chi Wah
    Cheung, Chi Wai
    Chiu, Tin Lok
    Lam, Wai Wang
    Cheung, Kin Yin
    Yu, Siu Ki
    MEDICAL DOSIMETRY, 2019, 44 (01) : 83 - 90
  • [6] Respiratory-gated dual fluoroscopic imaging for positioning and verification
    Sharp, G
    Jeung, A
    Ren, Y
    Povzner, S
    Berbeco, R
    Mostafavi, H
    Chen, G
    Jiang, S
    MEDICAL PHYSICS, 2005, 32 (06) : 2111 - 2111
  • [7] Dosimetric Evaluation of Respiratory-Gated VMAT On a Versa HD Linear Accelerator
    Snyder, J.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2017, 44 (06) : 2896 - 2896
  • [8] Reproducibility of image quality for moving objects using respiratory-gated computed tomography: a study using a phantom model
    Fukumitsu, Nobuyoshi
    Ishida, Masaya
    Terunuma, Toshiyuki
    Mizumoto, Masashi
    Hashimoto, Takayuki
    Moritake, Takashi
    Okumura, Toshiyuki
    Sakae, Takeji
    Tsuboi, Koji
    Sakurai, Hideyuki
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (06) : 945 - 953
  • [9] Development of a novel ArcCHECK™ insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities
    Fakir, H.
    Gaede, S.
    Mulligan, M.
    Chen, J. Z.
    MEDICAL PHYSICS, 2012, 39 (07) : 4203 - 4208
  • [10] Dosimetric Verification of Respiratory Gated VMAT for Lung SBRT Using 3-D Printed Lung Phantom
    Yoon, K. J.
    Kwak, J.
    Cho, B.
    Song, S. Y.
    Lee, S. W.
    Ahn, S. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E548 - E548