In vitro mechanical analysis of complete-arch mandibular implant-supported fixed prostheses abutment screws after cyclic loading

被引:4
|
作者
Sananez, Andreina [1 ]
Lefebvre, Carol [2 ]
Looney, Stephen [3 ]
Baker, Philip [4 ]
Mettenburg, Don [5 ]
Rueggeberg, Frederick A. [5 ]
机构
[1] Georgia Regents Univ, Coll Dent Med, Dept Oral Rehabil, Augusta, GA 30912 USA
[2] Georgia Regents Univ, Coll Dent Med, Augusta, GA 30912 USA
[3] Georgia Regents Univ, Coll Dent Med, Dept Biostat & Epidemiol, Augusta, GA 30912 USA
[4] Georgia Regents Univ, Coll Dent Med, Adv Educ Prosthodont Program, Augusta, GA 30912 USA
[5] Georgia Regents Univ, Coll Dent Med, Dept Oral Rehabil, Dent Mat Sect, Augusta, GA 30912 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2015年 / 113卷 / 05期
关键词
DENTAL IMPLANTS; COMPLICATION RATES; OBSERVATION PERIOD; PARTIAL DENTURES; TITANIUM; CONNECTION; FRAMEWORKS; PRELOAD; TIME; SUPERSTRUCTURE;
D O I
10.1016/j.prosdent.2014.09.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Clinicians question when to evaluate for worn or loose implant-supported retainer screws to prevent possible clinical complications. Purpose. The purpose of this study was to compare differences among initial and postdynamically loaded detorque values and identify physical structural changes of prosthetic retaining screws in a simulated implant-supported mandibular complete fixed prosthesis. Material and methods. Nine groups and nonloaded controls comprising a 5-implant-supported, milled titanium framework were fabricated and assembled (screw torque 35 Ncm). Dynamic loading (20 to 220 N) was applied to simulate 2 years of oral function. After testing, screw detorque values were measured (Delta T, initial-detorque value). A scanning electron microscopic analysis of screw threads was used to assess physical changes. Data were analyzed by 2-way ANOVA to determine the influence of loading and implant position on Delta T (alpha=.05). Results. Delta T values of loaded and nonloaded groups were compared separately at each implant position and showed a significant difference only for the implant in the central position (P=.002). All positions were compared in terms of Delta T values separately for loaded and nonloaded conditions. A significantly higher Delta T was found in 1 cantilever area of the loaded group, whereas a significantly lower Delta T value was found in the central position in the nonloaded group. No statistically significant differences were found in physical changes between loading and nonloading or among implant positions. Conclusions. When delivering a multiimplant supported prosthesis, the application of dynamic loading and the sequence in which implant screws are tightened could influence the subsequent detorque value of a screw; they have no effect on the physical appearance of screws after extended function.
引用
收藏
页码:432 / 439
页数:8
相关论文
共 50 条
  • [21] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104
  • [22] Alternative complete-arch cement-retained implant-supported fixed partial denture
    Hofstede, TM
    Ercoli, C
    Hagan, MF
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (01): : 94 - 99
  • [23] Marginal discrepancy of CAD-CAM complete-arch fixed implant-supported frameworks
    Yilmaz, Burak
    Kale, Ediz
    Johnston, William M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (01): : 65 - 70
  • [24] Five-year results with fixed complete-arch mandibular prostheses supported by 4 implants
    Eliasson, A
    Palmqvist, S
    Svenson, B
    Sondell, K
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2000, 15 (04) : 505 - 510
  • [25] Passively fitting implant-supported complete-arch interim restoration
    Liu, Xiaoqiang
    Li, Man
    Liu, Jianzhang
    Tan, Jianguo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (05): : 733 - 736
  • [26] Immediately loaded interim complete-arch implant-supported fixed dental prostheses fabricated with a completely digital workflow: A clinical technique
    Espona, Jose
    Roig, Elena
    Ali, Akram
    Roig, Miguel
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (04): : 423 - 427
  • [27] Relationship between Radiographic Misfit and Clinical Outcomes in Immediately Loaded Complete-Arch Fixed Implant-Supported Prostheses in Edentulous Patients
    Slauch, Robert W.
    Bidra, Avinash S.
    Wolfinger, Glenn J.
    Kuo, Chia-Ling
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (08): : 861 - 867
  • [28] Effect of different maintenance time of torque application on detorque values of abutment screws in full-arch implant-supported fixed prostheses
    Al-Otaibi, Hanan Nejer
    AL-Fouzan, Afnan F.
    Al-Mufleh, Tamadher S.
    Labban, Nawaf
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 848 - 851
  • [29] Conventional and digital maxillary occlusal record for the manufacture of complete-arch implant-supported fixed prostheses: randomized controlled clinical trial
    Pereira, Ana Larisse Carneiro
    Campos, Maria de Fatima Trindade Pinto
    Torres, Ana Clara Soares Paiva
    Carreiro, Adriana da Fonte Porto
    [J]. CLINICAL ORAL INVESTIGATIONS, 2024, 28 (05)
  • [30] A completely digital workflow for the transition from a failed dentition to interim complete-arch fixed implant-supported prostheses: A clinical report
    Negreiros, William Matthew
    Hamilton, Adam
    Gallucci, German O.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (04): : 527 - 532