Calibration of Line-Scan Cameras

被引:52
|
作者
Luna, Carlos A. [1 ]
Mazo, Manuel [1 ]
Luis Lazaro, Jose [1 ]
Vazquez, Juan F. [2 ]
机构
[1] Univ Alcala de Henares, Dept Elect, Alcala De Henares 28871, Spain
[2] LogyTel SL, Dept Res & Dev, Alcala De Henares 28805, Spain
关键词
Intrinsic and extrinsic camera parameters; line-scan calibration; optical distortion; perspective projection; pine-hole camera model;
D O I
10.1109/TIM.2009.2031344
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel method for calibrating line-scan cameras using a calibration pattern comprising two parallel planes with lines that can be described using known equations. Using pattern geometry and a line that is captured by a line-scan camera, we calculate the 3-D coordinates of the points corresponding to the straight lines of a pattern that is captured by the line-scan camera. These coordinates are used to obtain the intrinsic and extrinsic parameters of the line scan using a standard calibration procedure that is based on a recursive least squares method. In this paper, the procedure of calibration and the results obtained for a specific line scan will be shown; specifically, the obtained median residual error is 0.28 pixel. Also, the repetitiveness of the calibration process was verified for a sequence of 500 times.
引用
收藏
页码:2185 / 2190
页数:6
相关论文
共 50 条
  • [31] A calibration method for telecentric line-scan cameras with an enhanced dynamic imaging model and initial estimates derived from direct linear transformation
    Lian, Dongshan
    Huang, Jingzhi
    Yang, Runze
    Gao, Shouru
    Zheng, Yixuan
    Liu, Yongmeng
    Tan, Jiubin
    [J]. Measurement: Journal of the International Measurement Confederation, 2025, 241
  • [32] LINE-SCAN IMAGERY INTERPRETATION
    DELOOR, GP
    JURRIENS, AA
    LEVELT, WJM
    VANDEGEE.JP
    [J]. PHOTOGRAMMETRIC ENGINEERING, 1968, 34 (05): : 502 - &
  • [33] NOISY LINE-SCAN PICTURES
    WAGENAAR, WA
    VANMEETE.A
    [J]. PHOTOGRAMMETRIC ENGINEERING, 1969, 35 (11): : 1127 - &
  • [34] Line-scan CCD camera calibration in 2D coordinate measurement
    Ma, Weihong
    Dong, Tao
    Tian, Hui
    Ni, Jinping
    [J]. OPTIK, 2014, 125 (17): : 4795 - 4798
  • [35] Stereo line-scan sensor calibration for 3D shape measurement
    Sun, Bo
    Zhu, Jigui
    Yang, Linghui
    Guo, Yin
    Lin, Jiarui
    [J]. APPLIED OPTICS, 2017, 56 (28) : 7905 - 7914
  • [36] Tunnel linings inspection using Bayesian-Optimized (BO) calibration of multiple Line-Scan Cameras (LSCs) and a Laser Range Finder (LRF)
    Zou, Lin
    Huang, Yuchun
    Li, Yanan
    Chen, Yuxi
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 147
  • [37] It Allows a Portrait in Line-Scan at Fifteen
    Murray, Les
    [J]. FIDDLEHEAD, 2016, (268): : 149 - 150
  • [38] Flexible line-scan camera calibration method using a coded eight trigrams pattern
    Song, Kechen
    Hou, Bin
    Niu, Menghui
    Wen, Xin
    Yan, Yunhui
    [J]. OPTICS AND LASERS IN ENGINEERING, 2018, 110 : 296 - 307
  • [39] Line-scan focal modulation microscopy
    Pant, Shilpa
    Li, Caixia
    Gong, Zhiyuan
    Chen, Nanguang
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (05)
  • [40] IS LINE-SCAN ANALYSIS OF FORMATION FLAWED
    JORDAN, BD