Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography

被引:47
|
作者
Clevert, DA
Rupp, N
Reiser, M
Jung, EM
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Klin Radiol, D-81377 Munich, Germany
[2] Munich Univ Hosp, Grosshadern Clin Radiol, Munich, Germany
[3] Inst Diagnost Radiol, Passau, Germany
关键词
dissection; ultrasonography; Doppler studies;
D O I
10.1007/s00330-004-2481-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to evaluate the diagnostic results of different ultrasound techniques: color-coded Doppler (CCD), power Doppler (PD) and B-flow in the diagnosis of vascular dissection. Findings from 68 patients with arterial dissection proven either by vascular ultrasound (US) or by magnetic resonance angiography (MRA), computed tomographic angiography (CTA) or intra-arterial digital subtraction angiography (DSA) were reviewed in retrospect. The study compared results from three different modes of ultrasound, i.e., CCD, PD and B-flow, in dissections of the carotid artery (n= 11), of the vertebral artery (n=9), of the abdominal aorta (n= 13), of the iliac artery (n=12) and of the femoral artery (n=23). MRA, CTA and DSA were considered as reference standard. The sensitivity of CCD for detecting all dissections was 78%, 84% for the PD and 98% for B-flow. For carotid artery dissection, the sensitivity of CCD, PD and B-flow was 82, 91 and 98%, for the vertebral artery 67, 78 and 98%, for the abdominal aorta 85, 85 and 98%, for the iliac artery 67, 75 and 98%, for the femoral artery 83, 87 and 98%, respectively. Intima flaps, fissures of membranes and residual flow within the true and false lumen were better detected by B-flow than by CCD and PD. The lack of angle dependence of the US probe in B-flow made the examination procedure easier. In the cine mode of B-flow, the pulse synchronic movement of the membrane was more apparent than in any other imaging method. With B-flow, accuracy for the diagnosis of arterial dissection is improved compared to CCD and PD. Flow within the true and false lumen, low-echo thrombi, intramural hematoma and even movements of the dissection membrane are clearly distinguished.
引用
下载
收藏
页码:342 / 347
页数:6
相关论文
共 50 条
  • [21] DIAGNOSIS OF ARTERIO-PORTAL SHUNTS IN THE LIVER BY COLOR-CODED DOPPLER SONOGRAPHY
    STIGLBAUER, R
    HUBSCH, P
    GRITZMANN, N
    SCHWAIGHOFER, B
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1988, 149 (02): : 214 - 215
  • [22] Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography
    Clevert, D.-A.
    Johnson, T.
    Jung, E. M.
    Clevert, D.-A.
    Flach, P. M.
    Strautz, T. I.
    Ritter, G.
    Gallegos, M. T.
    Kubale, R.
    Becker, C.
    Reiser, M.
    EUROPEAN RADIOLOGY, 2007, 17 (08) : 2149 - 2159
  • [23] Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography
    D. -A. Clevert
    T. Johnson
    E. M. Jung
    D. -A. Clevert
    P. M. Flach
    T. I. Strautz
    G. Ritter
    M. T. Gallegos
    R. Kubale
    C. Becker
    M. Reiser
    European Radiology, 2007, 17 : 2149 - 2159
  • [24] B-flow imaging of the hepatic vasculature: Correlation with color Doppler sonography
    Wachsberg, Ronald H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (06) : W522 - W533
  • [25] COMPARISON OF COLOR-CODED DOPPLER SONOGRAPHY AND ANGIOGRAPHY FOR EXAMINING ARTERIES OF THE PELVIS AND LEG
    METZ, V
    BRAUNSTEINER, A
    GRABENWOGER, F
    DOCK, W
    VASA-JOURNAL OF VASCULAR DISEASES, 1988, : 28 - 29
  • [26] B-flow and color-coded B-flow in sonographic diagnosis of filiform stenosis of the internal carotid artery
    Jung, EM
    Clevert, DA
    Rupp, N
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (09): : 1251 - 1258
  • [27] Multi-slice CT angiography in the diagnosis of the degree of ICA stenosis: Comparison with color Doppler, power Doppler and B-flow
    Clevert, DA
    Wintersperger, BJ
    Becker, C
    Reiser, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 24 - 24
  • [28] COLOR-CODED DOPPLER SONOGRAPHY IN MONITORING NATIVE KIDNEY BIOPSIES
    ROLLINO, C
    GAROFALO, G
    ROCCATELLO, D
    SORRENTINO, T
    SANDRONE, M
    BASOLO, B
    QUATTROCCHIO, G
    MASSARA, C
    FERRO, M
    PICCIOTTO, G
    RENDINE, S
    PICCOLI, G
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1994, 9 (09) : 1260 - 1263
  • [29] EVALUATION OF ARTERIOVENOUS-MALFORMATIONS BY COLOR-CODED DOPPLER SONOGRAPHY
    HUBSCH, P
    TRATTNIG, S
    KAINBERGER, FM
    BARTON, P
    KARNEL, F
    ULTRASCHALL IN DER MEDIZIN, 1991, 12 (02): : 87 - 90
  • [30] HYPERVASCULARITY OF NONTOXIC GOITER AS SHOWN BY COLOR-CODED DOPPLER SONOGRAPHY