Focus Measure in a Liquid-filled Diaphragm (LFD) Lens Using Passive Auto-focus Method

被引:0
|
作者
Abdullah, S. J. [1 ]
Ratnam, M. M. [1 ]
Samad, Z. [1 ]
机构
[1] Univ Sains Malaysia, Sch Mech Engn, Nibong Tebal 14300, Malaysia
关键词
liquid-fill; diaphragm; lens; focus; FABRICATION; DESIGN;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Auto-focusing in imaging systems depends on the determination of the correct image focus criterion. In this research, the image captured by a liquid-filled diaphragm (LFD) fluid lens was analyzed to determine a focus measure criterion that can be used to establish the correct focus and thus quantify the image quality. The LFD lens was actuated using a stepper-motor driven syringe mechanism. The lens diaphragm was made of polydimethylsiloxane (PDMS) polymer that exhibit good optical properties. The lens focal length was controlled by varying the fluid volume within the diaphragm lens. A CCD camera was attached to the fluid lens to capture live images of a binary target. The edge slope width (ESW) of the pixel intensity profile across the white-to-black transition region in a binary target was used as the focus measure. The experiments carried out showed the viability of the proposed focus measure criterion for automatically focusing the image formed by a diaphragm-type fluid lens.
引用
收藏
页码:1086 / 1092
页数:7
相关论文
共 50 条
  • [31] A new auto-focus method in critical dimension measurement SEM
    Komatsu, F
    Motoki, H
    Miyoshi, M
    SIXTH ASIAN TEST SYMPOSIUM (ATS'97), PROCEEDINGS, 1997, : 202 - 207
  • [32] Simulating the functioning of variable focus length liquid-filled lenses using the finite element method (FEM)
    Santiago-Alvarado, A.
    Gonzalez-Garcia, J.
    Itubide-Jimenez, F.
    Campos-Garcia, M.
    Cruz-Martinez, V. M.
    Rafferty, P.
    OPTIK, 2013, 124 (11): : 1003 - 1010
  • [33] Paraxial ray solution for liquid-filled variable focus lenses
    Wang, Lihui
    Oku, Hiromasa
    Ishikawa, Masatoshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (12)
  • [34] A microscope system based on bevel-axial method auto-focus
    Chang, Ho-Chung
    Shih, Ta-Ming
    Chen, Nian Zu
    Pu, Nen-Wen
    OPTICS AND LASERS IN ENGINEERING, 2009, 47 (05) : 547 - 551
  • [35] An Measuring Method of Animal Fibers Diameter Based on Auto-focus Technology
    Zong Ya-ning
    PROCEEDINGS OF THE FIBER SOCIETY 2009 SPRING CONFERENCE, VOLS I AND II, 2009, : 680 - 683
  • [36] The analysis of the wave front aberration caused by the gravity of the tunable-focus liquid-filled membrane lens
    Zhang, Wei
    Liu, Pengfei
    Wei, Xiaona
    Zhuang, Songlin
    Yang, Bo
    OPTICAL DESIGN AND TESTING IV, 2010, 7849
  • [37] An Auto-focus Method for Microscopic Images Based on QSOM Neural Network
    Zhao, Dawei
    Gao, Jian
    Yang, Wenbo
    2021 PROCEEDINGS OF THE 40TH CHINESE CONTROL CONFERENCE (CCC), 2021, : 7054 - 7061
  • [38] Error-based autofocus system using image feedback in a liquid-filled diaphragm lens
    Abdullah, Soran J.
    Ratnam, Mani Maran
    Samad, Zahurin
    OPTICAL ENGINEERING, 2009, 48 (12)
  • [39] A model for auto-focus using location detection based on sound localization
    Porntrakoon, P
    Kesrarat, D
    Daengdej, J
    PROCEEDINGS OF THE IASTED INTERNATIONAL CONFERENCE ON APPLIED SIMULATION AND MODELLING, 2004, : 318 - 322
  • [40] Auto-focus pathology microscope using sub-array sampling
    Wu, Po-Hsun
    Weng, Chun-Jen
    Chen, Pi-Ying
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 922 - 926