Feasibility and Reliability of Quantifying Passive Muscle Stiffness in Young Children by Using Shear Wave Ultrasound Elastography

被引:60
|
作者
Brandenburg, Joline E. [1 ,2 ,3 ]
Eby, Sarah F. [7 ]
Song, Pengfei [4 ]
Zhao, Heng [4 ]
Landry, Bradford W. [2 ]
Kingsley-Berg, Shirley [4 ]
Bamlet, William R. [5 ]
Chen, Shigao [4 ]
Sieck, Gary C. [4 ]
An, Kai-Nan [4 ,6 ]
机构
[1] Mayo Clin, Dept Phys Med & Rehabil, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Pediat & Adolescent Med, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[5] Mayo Clin, Dept Hlth Sci Res, Rochester, MN 55905 USA
[6] Mayo Clin, Div Orthoped Res, Rochester, MN 55905 USA
[7] Mayo Clin, Coll Med, Mayo Grad Sch, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
elastography; feasibility; gastrocnemius muscle; pediatrics; pediatric ultrasound; skeletal muscle; ultrasound elastography; MEDIAL GASTROCNEMIUS; MOTION MEASUREMENTS; ELASTIC PROPERTIES; RANGE;
D O I
10.7863/ultra.34.4.663
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The purpose of this study was to investigate the feasibility and reliability of passive muscle stiffness measurements in children by shear wave ultrasound elastography. Methods-We conducted a prospective cross-sectional study quantifying the passive stiffness of bilateral lateral gastrocnemius muscles during passive stretching in 20 typically developing children (age range, 2.0-12.6 years). Data collected included passive stiffness of the lateral gastrocnemius muscle (shear modulus in kilopascals) at 4 positions of progressive passive foot dorsiflexion, demographic characteristics of the participants, and comparison of demographic characteristics with the shear modulus. Results-Passive stiffness increased with increasing stretching (mean [SD] range of stiffness, 7.1 [2.0] to 36.2 [22.0] kPa). For all 4 foot positions, no significant difference was found between right and left legs (range, P = .42 to P = .98) or between the sexes (range, P = .28 to P > .99). No correlation of passive muscle stiffness with age, body mass index, or ankle range of motion was found. The reliability of measurements was good to excellent (mean [95% confidence interval] range of reliability, 0.67 [0.44-0.83] to 0.80 [0.63-0.90]). Conclusions-Measurements of passive stiffness of the lateral gastrocnemius muscle are feasible and reliable in children as young as 2 years. Because this study found no significant difference between sex and the side tested in this age group, future studies involving children of this age range may not need to be stratified on the basis of these parameters. Defining normal passive muscle stiffness in children is critical for identifying and understanding the implications of abnormal passive muscle stiffness in children with neuromuscular disorders.
引用
收藏
页码:663 / 670
页数:8
相关论文
共 50 条
  • [21] Quantitative evaluation of passive muscle stiffness by shear wave elastography in healthy individuals of different ages
    Liu, Xiao
    Yu, Hong-kui
    Sheng, Shu-ya
    Liang, Si-min
    Lu, Hao
    Chen, Rui-yun
    Pan, Min
    Wen, Zhi-bo
    EUROPEAN RADIOLOGY, 2021, 31 (05) : 3187 - 3194
  • [22] Shear wave elastography of passive skeletal muscle stiffness: Influences of sex and age throughout adulthood
    Eby, Sarah F.
    Cloud, Beth A.
    Brandenburg, Joline E.
    Giambini, Hugo
    Song, Pengfei
    Chen, Shigao
    LeBrasseur, Nathan K.
    An, Kai-Nan
    CLINICAL BIOMECHANICS, 2015, 30 (01) : 22 - 27
  • [23] Quantifying Active and Passive Stiffness in Plantar Flexor Muscles Following Intermittent Maximal Isometric Contractions Using Shear Wave Elastography
    Vincent, Lheo
    Zidi, Mustapha
    Portero, Pierre
    Belghith, Kalthoum
    Serhal, Rayan Bou
    Guihard, Marina
    Maktouf, Wael
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (12): : 1987 - 1994
  • [24] Assessing the Effects of Aging on Muscle Stiffness Using Shear Wave Elastography and Myotonometer
    Do, Yerim
    Lall, Prarthana Sanya
    Lee, Haneul
    HEALTHCARE, 2021, 9 (12)
  • [25] Shear wave elastography of the spleen using elastography point quantification: stiffness values in healthy children
    Bhatia, Anmol
    Bhatia, Harsimran
    Saxena, Akshay Kumar
    Lal, Sadhna B.
    Sodhi, Kushaljit Singh
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2128 - 2134
  • [26] Comparison of liver stiffness assessment by transient elastography and shear wave elastography using six ultrasound devices
    Iijima, Hiroko
    Tada, Toshifumi
    Kumada, Takashi
    Kobayashi, Natsuko
    Yoshida, Masahiro
    Aoki, Tomoko
    Nishimura, Takashi
    Nakano, Chikage
    Ishii, Akio
    Takashima, Tomoyuki
    Sakai, Yoshiyuki
    Aizawa, Nobuhiro
    Nishikawa, Hiroki
    Ikeda, Naoto
    Iwata, Yoshinori
    Enomoto, Hirayuki
    Ide, Yoshi-Hiro
    Hirota, Seiichi
    Fujimoto, Jiro
    Nishiguchi, Shuhei
    HEPATOLOGY RESEARCH, 2019, 49 (06) : 676 - 686
  • [27] Shear wave elastography of the spleen using elastography point quantification: stiffness values in healthy children
    Anmol Bhatia
    Harsimran Bhatia
    Akshay Kumar Saxena
    Sadhna B. Lal
    Kushaljit Singh Sodhi
    Abdominal Radiology, 2022, 47 : 2128 - 2134
  • [28] Assessment of the cervical stiffness in pregnant women using Shear Wave Elastography: a feasibility study
    Muller, M.
    Ait-Belkacem, D.
    Gennisson, J. L.
    Fink, M.
    Tanter, M.
    Hessabi, M.
    Cabrol, D.
    Tsatsaris, V.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 5 - 8
  • [29] RELIABILITY OF SHEAR WAVE ELASTOGRAPHY AND ULTRASOUND MEASUREMENT IN CHILDREN WITH UNILATERAL SPASTIC CEREBRAL PALSY
    Boulard, Clement
    Mathevon, Laure
    Arnaudeau, Louis Florian
    Gautheron, Vincent
    Calmels, Paul
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (05): : 1204 - 1211
  • [30] Quantifying Myocardial Contractility Changes Using Ultrasound-Based Shear Wave Elastography
    Vejdani-Jahromi, Maryam
    Freedman, Jenna
    Nagle, Matthew
    Kim, Young-Joong
    Trahey, Gregg E.
    Wolf, Patrick D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (01) : 90 - 96