Analysis of 4-bromo-3-fluorobenzaldehyde and separation of its regioisomers by one-dimensional and two-dimensional gas chromatography
被引:1
|
作者:
Shen, Bo
论文数: 0引用数: 0
h-index: 0
机构:
Amgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USAAmgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USA
Shen, Bo
[1
]
Semin, David
论文数: 0引用数: 0
h-index: 0
机构:
Amgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USAAmgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USA
Semin, David
[1
]
Fang, Jan
论文数: 0引用数: 0
h-index: 0
机构:
Qual & Regulatory Management LLC, 2629 Townsgate Rd, Westlake Village, CA 91361 USAAmgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USA
Fang, Jan
[2
]
Guo, Gary
论文数: 0引用数: 0
h-index: 0
机构:
Gilead Sci, Commercial Analyt Operat, 333 Lakeside Dr, Foster City, CA 94404 USAAmgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USA
Guo, Gary
[3
]
机构:
[1] Amgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USA
[2] Qual & Regulatory Management LLC, 2629 Townsgate Rd, Westlake Village, CA 91361 USA
[3] Gilead Sci, Commercial Analyt Operat, 333 Lakeside Dr, Foster City, CA 94404 USA
A starting material, 4-bromo-3-fluorobenzaldehyde, was used for active drug substance (API) AMG 369 production. The presence of the regioisomer impurities in the starting material 4-bromo-3-fluorobenzaldehyde presented significant challenges for the API synthetic route development due to the physical-chemical similarities of the impurities. These impurities significantly impact on the purity of the starting-material and final drug substance. Control of these impurities is important due to the potential genotoxicity of these impurities (p-GTI). Analytical development was carried out to develop GC methods with high resolving power and high sensitivity to quantify the regioisomers presented in starting material and therefore to control the purity of the starting material and the final drug substance. In the study, complete resolution of the ten regioisomers by 1D-GC and heart-cutting two-dimensional GC (2D-GC) was achieved. A sensitive GC/micro electron capture detection (mu-ECD) method with high resolving power and sensitivity to fully resolve all the ten regioisomers of 4-bromo-3-fluorobenzaldehyde was obtained by using a CHIRALDEX GC column (1D-GC). To facilitate the systematic GC method development, heart-cutting two-dimensional gas chromatography (2D-GC) using a Deans switch was exploited for the separation of the ten regioisomers. The resulting heart-cutting 2D-GC method successfully separated all the ten regioisomers with better sensitivity and resolution. Regioisomer impurities in the starting material were identified and quantified by these GC methods. The sensitivity for the methods is in the range of 0.004 ng to 0.02 ng for the regioisomers. Linearity for the methods is: R-2 = 0.999 to 1.000. The methods were suitable for control of the regioisomer impurities, p-GTIs, in the starting material and final drug substance. (C) 2016 Elsevier B.V. All rights reserved.