Analysis of 4-bromo-3-fluorobenzaldehyde and separation of its regioisomers by one-dimensional and two-dimensional gas chromatography

被引:1
|
作者
Shen, Bo [1 ]
Semin, David [1 ]
Fang, Jan [2 ]
Guo, Gary [3 ]
机构
[1] Amgen Inc, Attribute Sci, One Amgen Ctr Dr, Thousand Oaks, CA 91320 USA
[2] Qual & Regulatory Management LLC, 2629 Townsgate Rd, Westlake Village, CA 91361 USA
[3] Gilead Sci, Commercial Analyt Operat, 333 Lakeside Dr, Foster City, CA 94404 USA
关键词
GC; mu-ECD; Deans switch; 1D-GC; 2D-GC; Chiral GC column; regioisomers; p-GTI; INSTRUMENTATION; IMPURITIES;
D O I
10.1016/j.chroma.2016.07.071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A starting material, 4-bromo-3-fluorobenzaldehyde, was used for active drug substance (API) AMG 369 production. The presence of the regioisomer impurities in the starting material 4-bromo-3-fluorobenzaldehyde presented significant challenges for the API synthetic route development due to the physical-chemical similarities of the impurities. These impurities significantly impact on the purity of the starting-material and final drug substance. Control of these impurities is important due to the potential genotoxicity of these impurities (p-GTI). Analytical development was carried out to develop GC methods with high resolving power and high sensitivity to quantify the regioisomers presented in starting material and therefore to control the purity of the starting material and the final drug substance. In the study, complete resolution of the ten regioisomers by 1D-GC and heart-cutting two-dimensional GC (2D-GC) was achieved. A sensitive GC/micro electron capture detection (mu-ECD) method with high resolving power and sensitivity to fully resolve all the ten regioisomers of 4-bromo-3-fluorobenzaldehyde was obtained by using a CHIRALDEX GC column (1D-GC). To facilitate the systematic GC method development, heart-cutting two-dimensional gas chromatography (2D-GC) using a Deans switch was exploited for the separation of the ten regioisomers. The resulting heart-cutting 2D-GC method successfully separated all the ten regioisomers with better sensitivity and resolution. Regioisomer impurities in the starting material were identified and quantified by these GC methods. The sensitivity for the methods is in the range of 0.004 ng to 0.02 ng for the regioisomers. Linearity for the methods is: R-2 = 0.999 to 1.000. The methods were suitable for control of the regioisomer impurities, p-GTIs, in the starting material and final drug substance. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 50 条
  • [1] Flow optimization in one-dimensional and comprehensive two-dimensional gas chromatography
    Blumberg, Leonid M.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1536 : 27 - 38
  • [2] Comparison of one-dimensional and comprehensive two-dimensional separations by gas chromatography
    Blumberg, Leonid M.
    David, Frank
    Klee, Matthew S.
    Sandra, Pat
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (01) : 2 - 16
  • [3] The need for two-dimensional gas chromatography: Extent of overlap in one-dimensional gas chromatograms
    Davis, JM
    Samuel, C
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (03): : 235 - 244
  • [4] One-dimensional and two-dimensional liquid chromatography of sulphonated lignins
    Brudin, Stella
    Berwick, James
    Duffin, Mike
    Schoenmakers, Peter
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (02) : 196 - 201
  • [5] ONE-DIMENSIONAL, TWO-DIMENSIONAL, AND 3-DIMENSIONAL ARRAYS
    ADAMS, AT
    LEVIATAN, Y
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1987, 29 (04) : 314 - 316
  • [6] Characterization of polyolefins-based pyrolysis oils: A comparison between one-dimensional gas chromatography and two-dimensional gas chromatography
    Perez, Barbara Alejandra
    Krishna, J. V. Jayarama
    Toraman, Hilal Ezgi
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1739
  • [7] One-Dimensional and Two-Dimensional Analyses of Hard Coal Separation in a Jig
    Pieta, Paulina
    INZYNIERIA MINERALNA-JOURNAL OF THE POLISH MINERAL ENGINEERING SOCIETY, 2015, (01): : 133 - 138
  • [8] Sensitivity of Comprehensive Two-dimensional Gas Chromatography (GCxGC) Versus One-dimensional Gas Chromatography (1D GC)
    Mostafa, Ahmed
    Gorecki, Tadeusz
    LC GC EUROPE, 2013, 26 (12) : 672 - 679
  • [9] Considerations on the determination of the limit of detection and the limit of quantification in one-dimensional and comprehensive two-dimensional gas chromatography
    Krupcik, Jan
    Majek, Pavel
    Gorovenko, Roman
    Blasko, Jaroslav
    Kubinec, Robert
    Sandra, Pat
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1396 : 117 - 130
  • [10] TWO-DIMENSIONAL HOLE GAS IN A ONE-DIMENSIONAL SUPER-LATTICE
    KVON, ZD
    KOLTSOV, BB
    NEIZVESTNYI, IG
    OVSYUK, VN
    JETP LETTERS, 1981, 33 (11) : 571 - 574